• Title/Summary/Keyword: Dental Laboratory Technology

Search Result 691, Processing Time 0.023 seconds

Comparison of the Marginal Fitness of Ceramic Co-Cr Metal Crown (도재용 코발트-크롬 금속관의 변연적합도 비교)

  • Jeon, Byung-Wook;Kim, Bu-Sob
    • Journal of Technologic Dentistry
    • /
    • v.37 no.2
    • /
    • pp.69-76
    • /
    • 2015
  • Purpose: In this study, the marginal fitness of ceramic Co-Cr metal crown made by precision casting, milling, and selective laser melting method were compared. Methods: The ceramic Co-Cr metal crown manufactured by precision casting used the lost wax(LC specimen) method. The abutment were scanned and then made by milling(CM specimen), selective laser melting(CS specimen) method. The specimen were cut bucco-lingual and mesio-distal, and absolute marginal discrepancy and marginal gap were measured using a digital microscope. The surface roughness of the crown was also observed. Results: On the bucco-lingual axial, absolute marginal discrepancy was the LC specimen $31.72({\pm}4.58){\mu}m$, the CM specimen $78.29({\pm}3.28){\mu}m$ and the CS specimen $143.13({\pm}3.83){\mu}m$, respectively. On the bucco-lingual axial, marginal gap was the LC specimen $22.70({\pm}1.46){\mu}m$, the CM specimen $22.70({\pm}1.49){\mu}m$ and CS specimen $99.60({\pm}1.57){\mu}m$, respectively. Conclusion: For ceramic Co-Cr metal crowns, LC specimen was superior for absolute marginal discrepancy and marginal gap. The surface of metal crowns by selective laser melting were the roughest.

Characteristics of titanium polarization curve and formation of nanomesh by electrochemical method (전기화학적 방법에 의한 타이타늄 분극특성 및 나노메쉬 형성)

  • Park, Jin-Seo;Kim, Bu-Sub
    • Journal of Technologic Dentistry
    • /
    • v.38 no.2
    • /
    • pp.79-84
    • /
    • 2016
  • Purpose: The aim of this study was to make nanomesh on the surface of titanium by potentiostatic technique which was done at the suitable potential level. Methods: In order to find the suitable potential level, use a $25^{\circ}C$ NaCl, NaOH and NH4F solution of 1 M and 5 M as supporting electrolyte, working electrode(positive potential) was contact to the titanium specimen and counter electrode(negative potential) was contact to the Pt substrate. At the transpassive potential which was observed by potentiostatic technique, potentiostatic technique was done for 2hours. Results: As a result, 1 M NaOH solution was suitable as a supporting electrolyte, potentiostatic technique used a $25^{\circ}C$ NaOH solution of 1 M for 2hours, nanomesh was formed. Conclusion: The potentiostatic technique was used $25^{\circ}C$ NaOH solution of 1 M and 5 M as supporting electrolyte for 2hours. Nanomesh was built more uniform and fine in 1 M NaOH solution than 5 M NaOH solution.

Fracture Strength Analysis of Monolithic Zirconia Ceramic by Abutment Shape (지르코니아 단일구조 전부도재관의 지대치 형태에 따른 파절 강도)

  • Kim, Won-Young;Hong, Min-Ho
    • Journal of Technologic Dentistry
    • /
    • v.36 no.4
    • /
    • pp.231-237
    • /
    • 2014
  • Purpose: This study was performed fracture strength test by conducted change of abutment and coping shape for suggesting monolithic all ceramic crown which has thin thickness and superior strength of the occlusal surface. Methods: The specimens on the four kinds abutment was made according to thickness of occlusal surface and angle of axis surface. And All ceramic coping specimens of 6 different kinds was made by the CAD/CAM Method. Compression strength test using the UTM and the verification of compression-stress situation using the 3D finite element method were conducted under optimum conditions. Results: 516C specimen was showed the strongest compression-fracture strength, followed by 516FR, 516F45, specimens. Did not show significant differences between 516FR and 516F45. 516C of the universal testing machine the specimen's surface that are within the vertical load is small, finite element method of a uniformly distributed load, so the value received suggests otherwise. Conclusion: In conclusion, abutments of monolithic ziconia ceramic when having a same thickness of the occlusal, as the angle of occlusal edge is small, the stress is well dispersed and it can endure well in the fracture.

Flexural strength of indirect composite resin with different polymerization conditions (중합 조건에 따른 간접복합레진의 굴곡강도)

  • Geum, Young-Hee;Kim, Busob
    • Journal of Technologic Dentistry
    • /
    • v.35 no.4
    • /
    • pp.333-341
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the flexural strength of indirect composite resins with different polymerization conditions. Methods: Ten specimens ($2mm{\times}2mm{\times}25mm$) of each composite resins (Tescera (T), Gradia (S) and Sinfony (S)) were fabricated by two polymerization methods : manufacturers's and light heat pressure. Composite resins polymerized by manufacturers's method and light heat pressure served as control (TS, GS and SS) and experimental groups (TE, GE and SE), respectively. The composite resins were tested for flexural strength and the surface of composite resins were observed with scanning electron microscope (SEM) under X1,000 magnification. Results: The flexural strength values of cured composite resin decreased in the following order: TE (195.4MPa), TS (179.8MPa), GE (169.9MPa), SE (137.7MPa), SS (111.1MPa) and GS (100.9MPa) groups. Conclusion: The flexural strength values between the control and the experimental groups were not significantly different although experimental groups showed higher flexural strength values than control groups.

A Study of Three-dimensional evaluation of the accuracy of resin provisional restorations fabricated with the DLP printer (DLP 프린터로 제작된 레진 임시수복물의 3차원적 정확도 평가)

  • Kang, Wol;Lee, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.42 no.1
    • /
    • pp.35-41
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the accuracy of the DLP 3D printer by conducting 3-dimensional assesment of resin provisional restorations. Methods: The first premolar of the maxillary was prepared for the abutment. The abutment was scanned by using a scanner. The provisional restoration was designed by using CAD software. A total of 16 resin provisional restorations were produced using ZD200 and Veltz DLP 3D printer. Scanning was done of resin provisional restorations and 3-dimensional measurement was conducted for accuracy. The mean (SD) of RMS was reported for each group. Independent t-test was used to assess the statistical significance of the results. All analyses were done using SPSS 22.0. Results: The mean ± SD of RMS value for the accuracy of the resin provisional restorations that was fabricated by using ZD200 and Veltz DLP 3D printer were 50.85.±4.64㎛ and 70.33±6.31㎛. Independent t-test showed significant differences between groups(p<0.001). Conclusion: The resin provisional restorations made with DLP 3D printers showed clinically acceptable accuracy.

Comparative analysis of the flexural strength of provisional restorative resins using a digital light processing printer according to the post-curing method (디지털 광원 처리 프린터로 제작된 임시수복용 레진의 후경화 기계에 따른 굴곡강도 연구)

  • Park, Young-Dae;Kang, Wol
    • Journal of Technologic Dentistry
    • /
    • v.42 no.4
    • /
    • pp.341-347
    • /
    • 2020
  • Purpose: This study aimed to evaluate the effect of post-curing method on the flexural strength of provisional restorative resins produced by a digital light processing printer. Methods: A total of 20 specimens were produced, with a length of 64 mm, width of 10 mm, and thickness of 3.3 mm using a digital light processing printer. Two types of provisional restorative resins made with different post-curing methods were investigated and divided into conventional and vacuum groups. For the flexural strength test, each group was prepared by each method according to ISO 10477, and the flexural strength was measured with a universal testing machine. For statistical analysis, data were analyzed by independent t-test and Mann-Whitney U test. Results: The flexural strengths of the conventional and vacuum groups were 151.89 MPa and 131.94 MPa, respectively, showing a statistically significant difference (p<0.05). Conclusion: Within the limitation of this study, provisional restorative resins produced with vacuum demonstrated lower flexural strength than those produced with conventional postcuring method.

Comparison of shrinkage according to thickness of photopolymerization resin for 3D printing (3D 프린팅용 광 중합 수지의 두께에 따른 수축 비교)

  • Kim, Dong-Yeon;Kim, Jae-Hong
    • Journal of Technologic Dentistry
    • /
    • v.43 no.1
    • /
    • pp.1-5
    • /
    • 2021
  • Purpose: To perform a comparative study on curing shrinkage according to the thickness of photopolymerization resin. Methods: Stainless steel molds of 2, 4, and 6 mm heights were prepared. The 2, 4, and 6 mm-height molds were classified as the 2H, 4H, and 6H groups, respectively. A photopolymerization resin was injected into the stainless steel mold. Photopolymerization was carried out using a photopolymer machine. During photopolymerization, the wavelength and intensity of 400~405 nm were set to 10, the highest intensity among 1~10. Photopolymerization was performed for 30 min per specimen (each group=10). The inner and outer areas of the specimen were measured. The data were analyzed using one-way ANOVA and Kruskal-Wallis H test (α=0.05). Results: In terms of the inner and outer diameters of the photopolymerization resin specimen, the 2H group contracted the most, whereas the 6H group contracted the least. A statistically significant difference was found between the groups (p<0.05). Conclusion: The amount of light irradiation of the photopolymerization resin must be adjusted according to the thickness.

A analysis of Factors Influencing Dental Technicians Recognition Level of Their Occupational Disease (치과기공사의 직업병인식에 영향을 미치는 요인분석)

  • Lee, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.15 no.1
    • /
    • pp.43-61
    • /
    • 1993
  • This study was conducted to determine factors influencing dental technicians recognition level of their occupational disease. After self-administered questionnaire were distributed by mail to 540 technicians clustered samplely semplely selected from dental laboratories resistered in seoul and pusan Korean Dental Laboratory Association 395 technicians responded from march 29 through April 27, 1993. The results are as follows. 1. The recognition level of an occupational disease of the total 395 respondents by sex is higher among male than female. The difference was found to be meaningful(p <.05). 2. When the recognition level of an occupational disease being tested with 45 as the highest point possible, the average point 31.41 $\pm$ 6.50 of the total respondents reflected a high level of recognition. The highly recognized items were stress, bronchial disease, hearing loss. 3. With the highest points in Wallston and Wallstons' health locus of control in personality being 54, the average points of the dental technicians in the study was 35.41 $\pm$ 4.93. 4. As for the medical care patterns, the rate was higher among local medical insurance 64.4% than none 16.8%, company medical isurance 9.2%, medical aide 6.7%, others 2.6%. As for the experience of utilization of outpatient servelies, Yes was 40.4% and 59.6%, showing a meaningful difference(t=.80, p<.05).01) accounted total variance of the factors influencing dental technicians recognition level of their occupational disease(p<.0.000), R-squaire is 0.08.

  • PDF

Comparing Fitness of Casting Crowns with Various Investments and Casting Metals (각종매몰재와 주조 금속에 따른 주조관의 적합도에 관한 실험적 연구)

  • Lee, Byoung-Ki;Cha, Sung-Soo;Kim, Won-Tai
    • Journal of Technologic Dentistry
    • /
    • v.5 no.1
    • /
    • pp.13-17
    • /
    • 1983
  • The experimental investication wax performed to study fitness of casting crowns with various investment widely used in Korea. 36 wax patterns were invested and casted according to the regular casting method. The result were as follow : 1. Casting with cristobalite investments of Shofu were seen apart, 0.04mm the tightest space in the linguo and bucco-cervical margin. And the largest deviation, 0.1mm was shown in the central groove 0.1mm was shown in the central groove area of occlusal surface(Jensen Metal) 2. Casting with cristobalite investments of kerr were seen apart, 0.04mm the tightest space in the linguo and bucco-cervical margin And the largest deviation, 0.09 was shown in the central groove area of occlusal surface(Jensen Metal) 3. Casting with Quartz investments of G-C were seen apart, 0.04mm the tightest space in the linguo-cervical margin, And the largest deviation, 0.1mm was shown in the central groove area of occlusal surface(Jensen Metal) 4. Casting with cristobalite investments of shofu were seen apart, 0.01mm the tightest space in the linguo-cervical margin, And the largest deviation, 0.03mm was shown in the central groove of occusal surface(Bo-sung A type gold alloy) 5. Casting with cristobalite investments of kerr showed the best fintness in linguo-cervical margin. And the largest deviation, 0.02mm was shown in the central groove area of occlusal surface(Bosung A type gold alloy) 6. Casting with Quartz investments of G-C were Seen apart, 0.02mm the tightest space in the linguo-cervical margin, And the largest deviation, 0.04mm was shown in the central groove area of occlusal surface(Bo-sung A type gold alloy) 7. Casting with cristobalite investments of shofu were seen apart, 0.01mm the tightest space in the linguo-cervical margin. And the largest deviation, 0.08mm was shown in the buccal cusp area of occlusal surface(Bo-sung B type gold alloy) 8. Casting with cristobalite investments of kerr shown the best fitness in linguo-cervical margin. And the largest deviation, 0.04mm was shown in the central groove atea of occlusal surface(Bosung B type gold alloy) 9. Casting with Quartz investments of G-C were seen apart, 0.03mm the tightest space in the linguo-cervical margin. And the largest deviation, 0.04mm was shown in the central groove area of occlusal surface(Bo-sung B type gold alloy) 10. Casting with cristobalite investments of kerr shown the best fitness and Bo-sung A type gold alloy showed the best fitness.

  • PDF

Effect of tooth bleaching agents on color of tooth depend on content of carbamide peroxide (Carbamide peroxide의 함량에 따른 치아미백제의 치아에 대한 효과)

  • Chung, Suk-Min;Nam, Sang-Yong;Kwak, Dong-Ju
    • Journal of Technologic Dentistry
    • /
    • v.23 no.1
    • /
    • pp.85-93
    • /
    • 2001
  • The purpose of this study was to evaluate the effects of commercial home-tooth bleaching agents on the color of tooth. Twenty five sound extracted teeth were randomly divided into five groups. The color differences between before and after treatment with five types of tooth bleaching agents (7.5% hydrogen peroxide Nite White $Excel^{(R)}$, 10% carbamide peroxide Nite White $Excel^{(R)}$, 16% carbamide peroxide Nite White $Excel^{(R)}$, 10% carbamide peroxide Insta-BriteTM, 20% carbamide peroxide Insta-$Brite^{TM}$) were evaluated. The results were as follows: 1. By 2 week home tooth bleaching agent applications, the values ($L^*$) of bovine teeth increased as high as 4.38 $\sim$ 8.80 when comparing to those of the samples before treatment, and the color difference (${\Delta}E^*$) showed as high as 10.16 $\sim$ 15.04. 2. 16% carbamide peroxide Nite White Excel induced significantly greater ${\Delta}L^*$ than other test edgroups except for 7.5% hydrogen peroxide Day White Excel, and significantly greater ${\Delta}E^*$ than other tested groups by 2 week bleaching agent treatments (p<0.01). 3. 16% carbamide peroxide Nite White Excel(${\Delta}L^*$=8.80, ${\Delta}E^*$=15.04) induced significantly greater ${\Delta}L^*$ and ${\Delta}E^*$ than 10% carbamide peroxide Nite White Excel(${\Delta}L^*$=5.01, ${\Delta}E^*$=10.16)(p<0.01), but significant difference between 10% carbamide peroxide Insta-Brite(${\Delta}L^*$=4.38, ${\Delta}E^*$=10.51) and 20% carbamide peroxide Insta-Brite(${\Delta}L^*$=5.63, ${\Delta}E^*$=11.23) was not shown in ${\Delta}L^*$ and ${\Delta}E^*$(p>0.01). 4. 16% carbamide peroxide Nite White Excel(${\Delta}L^*$=8.80, ${\Delta}E^*$=15.04) which were applied in night time induced significantly greater ${\Delta}L^*$ and ${\Delta}E^*$ than 7.5% hydrogen peroxide Day White Excel(${\Delta}L^*$=8.47, ${\Delta}E^*$=12.75) which were applied in day time. Conclusions: These results demonstrate that all the commercial home-tooth bleaching agents have appreciable bleaching effect on teeth, and the effects of home-tooth bleaching agents which are used during night time are affected by content of carbamide peroxide. Especially the whitening effect of home tooth bleaching agents that are used through night time is greater than that of short time-applying tooth bleaching agent.

  • PDF