Comparing Fitness of Casting Crowns with Various Investments and Casting Metals

각종매몰재와 주조 금속에 따른 주조관의 적합도에 관한 실험적 연구

  • Lee, Byoung-Ki (Dept. of Dental Laboratory Technology Dea Jun Junior Health College) ;
  • Cha, Sung-Soo (Dept. of Dental Laboratory Technology Dea Jun Junior Health College) ;
  • Kim, Won-Tai (Dept. of Dental Laboratory Technology Dea Jun Junior Health College)
  • 이병기 (대전보건전문대학 치기공과) ;
  • 차성수 (대전보건전문대학 치기공과) ;
  • 김원태 (대전보건전문대학 치기공과)
  • Published : 1983.07.01

Abstract

The experimental investication wax performed to study fitness of casting crowns with various investment widely used in Korea. 36 wax patterns were invested and casted according to the regular casting method. The result were as follow : 1. Casting with cristobalite investments of Shofu were seen apart, 0.04mm the tightest space in the linguo and bucco-cervical margin. And the largest deviation, 0.1mm was shown in the central groove 0.1mm was shown in the central groove area of occlusal surface(Jensen Metal) 2. Casting with cristobalite investments of kerr were seen apart, 0.04mm the tightest space in the linguo and bucco-cervical margin And the largest deviation, 0.09 was shown in the central groove area of occlusal surface(Jensen Metal) 3. Casting with Quartz investments of G-C were seen apart, 0.04mm the tightest space in the linguo-cervical margin, And the largest deviation, 0.1mm was shown in the central groove area of occlusal surface(Jensen Metal) 4. Casting with cristobalite investments of shofu were seen apart, 0.01mm the tightest space in the linguo-cervical margin, And the largest deviation, 0.03mm was shown in the central groove of occusal surface(Bo-sung A type gold alloy) 5. Casting with cristobalite investments of kerr showed the best fintness in linguo-cervical margin. And the largest deviation, 0.02mm was shown in the central groove area of occlusal surface(Bosung A type gold alloy) 6. Casting with Quartz investments of G-C were Seen apart, 0.02mm the tightest space in the linguo-cervical margin, And the largest deviation, 0.04mm was shown in the central groove area of occlusal surface(Bo-sung A type gold alloy) 7. Casting with cristobalite investments of shofu were seen apart, 0.01mm the tightest space in the linguo-cervical margin. And the largest deviation, 0.08mm was shown in the buccal cusp area of occlusal surface(Bo-sung B type gold alloy) 8. Casting with cristobalite investments of kerr shown the best fitness in linguo-cervical margin. And the largest deviation, 0.04mm was shown in the central groove atea of occlusal surface(Bosung B type gold alloy) 9. Casting with Quartz investments of G-C were seen apart, 0.03mm the tightest space in the linguo-cervical margin. And the largest deviation, 0.04mm was shown in the central groove area of occlusal surface(Bo-sung B type gold alloy) 10. Casting with cristobalite investments of kerr shown the best fitness and Bo-sung A type gold alloy showed the best fitness.

Keywords