• 제목/요약/키워드: Dental Implantation

Search Result 265, Processing Time 0.024 seconds

Fabrication of Glass Ceramics for Dental Artificial Tooth(II) -Biocompatibility- (인공 치아용 결정화 유리의 제조(II) - 생체적합성)

  • 유기수;한복섭
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.257-264
    • /
    • 1993
  • A study on the biocompatibility of two types of new glass-ceramics materials, metal disc and dental porcelain that were already made for dental artificial tooth in the previous study, have been attempted. The chemical behavior and the Victor's hardness change in she artificial saliva and Ringer's solution have been also investigated. From the experiment of Implantation of glass-ceramics Into dorsal subcutaneous tissue of Sprague-Dawley rats, glass-cerarmics did not show any particular system of rejection for histrocompatibility.

  • PDF

Bone Healing around Screw - shaped Titanium Implants with Three Different Surface Topographies (임플란트의 표면처리 유형에 따른 골 치유 양상)

  • Koh, Young-Han;Kim, Young-Jun;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.1
    • /
    • pp.41-57
    • /
    • 2001
  • It is well known that the apposition of bone at implant surface would be influenced by the microstructure of titanium implants. The purpose of this study was to compare bone healing around the screw-shaped titanium implant with three different surface topographies in the canine mandibles by histological and biomechanical evaluation. All mandibular premolars of six mongrel dogs were extracted and implants were placed one month later. The pure titanium implants had different surface topographies: smooth and machined ($Steri-OSS^{(R)}$: Group II); sandblasted and acid-etched ($ITI^{(R)}$, SLA: Group III) surface. The fluorescent dyes were injected on the 2nd (calcein), 4th (oxytetracycline HCI) and 12th (alizarin red) weeks of healing. Dogs were sacrificed at 4 and 12 weeks after implantation. The decalcified and undecalcified specimens were prepared for histological and histo-metrical evaluation of implant-bone contact. Some specimens at 12 weeks after implantation were used for removal torque testing. Histologically, direct bone apposition to implant surface was found in all of the treated groups. More mature and dense bone was observed at the implant-bone interface at 12 weeks than that at 4 weeks after implantation. Under the fluorescent microscope, thick regular green fluorescent lines which mean early bone apposition were observed at the implant-bone interface in Group III, while yellow and red fluorescent areas were found at the implant-bone interface in Group I and II. The average implant-bone contact ratios at 4 weeks of healing were 54.3% in Group I, 57.7% in Group II and 66.2% in Group III. In Group I, implant-bone contact ratio was significantly lower than Group II and III(p<0.05). The average implant-to-bone contact ratios at 12 weeks after implantation were 64.3% in Group I, 66.7% in Group II and 71.2% in Group III. There was no significant difference among the three groups. In Group I and II, the implant-bone contact ratio at 12 weeks increased significantly in comparison to ratio at 4 weeks(p<0.05). The removal torque values at 12 weeks after implantation were 90.9 Ncm in Group I, 81.6 Ncm in Group II and 77.1 Ncm in Group III, which were significantly different(p<0.05). These results suggest that bone healing begin earlier and be better around the surface-treated implants compared to the smooth surface implants. The sandblasted and acid-etched implants showed the most favorable bone response among the three groups during the early healing stage and could reduce the waiting period prior to implant loading.

  • PDF

Zirconia ceramic fixed dental prosthesis with all-on-4 concept implants for irradiated maxilla: A case report (방사선 조사된 상악골에서 all-on-4 임플란트에 의해 지지되는 지르코니아 고정성 보철물 수복 증례)

  • Choi, Eun-Joo;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.218-224
    • /
    • 2017
  • The implant-supported fixed dental prosthesis in irradiated maxilla needs meticulous treatment planning due to low bone healing capacity. All-on-4 concept implantation can reduce the number of implants to be placed avoiding bone grafting procedure. Conventionally, prefabricated angled abutments for tilted implants have been used. However, in this case, it was replaced with computer-aided design and computer-aided manufacturing (CAD/CAM) abutment. This case report described all-on-4 concept implantation and fabrication of CAD/CAM zirconia fixed dental prostheses using CAD/CAM titanium abutments.

ASSESSMENT OF BONE DENSITY ON MAXILLA AFTER IMPLANTATION WITH CONE BEAM COMPUTED TOMOGRAPHY (Cone Beam Computed Tomography를 이용한 상악 임플란트 식립 전후의 골밀도 변화에 관한 연구)

  • Choi, Jeong-Hun;Lee, Ju-Min;Kim, Yong-Deok;Shin, Sang-Hun;Chung, In-Kyo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.3
    • /
    • pp.229-235
    • /
    • 2010
  • Purpose: This study examined the significance of increased bone density according to time after implantation on maxilla using demographic data with CBCT and compared the bone density between before vs. after implantation using the Hounsfield index. Materials and Methods: Twenty-five implant site on maxilla were selected. Cone-beam computerized tomography (CBCT) scans were used for the analysis. The implant sites were evaluated digitally using the Hounsfield scale with EzImplant TM and the results were compared over time. Statistical data over time was carried out to determine the correlation between the recorded Hounsfield unit (HU) over time and gender difference using repeated ANOVA. Results: The bone density of implantation site over time showed an increase in the HU mean values. Immediately after implantation, bone density was significantly increased than bone density before implantation. Until 6 month follow-up, bone density showed stable increasement. There is no significant difference on gender. Conclusions: Using CBCT, bone density increased over time after implantation on maxilla. Bone density measurements using CBCT might provide an objective assessment of the bone quality as well as the correlation between bone density and stability of implant.

Consideration of Vertical Position for predictable posterior implant - Deep implantation for Implant Biologic width (예지성 있는 구치부 임플란트를 위한 임플란트의 수직적 깊이에 대한 고려 Implant Biologic width를 위한 Deep Implantation)

  • Yun, Woo-Hyuk
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.27-41
    • /
    • 2019
  • For predictable posterior implants, appropriate soft tissue thickness, called the biologic width, is required around the implant for crestal bone stability. In order to do so, it seems that there are many cases where the implant should be positioned deeper than the depth that we previously thought was appropriate or inevitable limit. I would like to share my clinical experience about the vertical position of the posterior implant with the case reports and the related surgical technique.

Effect of Cytochalasin B in Activation Medium on the Development of Rat Somatic Cell Nuclear Transfer Embryos

  • Roh, Sang-Ho
    • Reproductive and Developmental Biology
    • /
    • v.31 no.2
    • /
    • pp.109-113
    • /
    • 2007
  • This study was conducted to evaluate the effect of cytochalasin B (CB) treatment in the activation medium on the development of somatic cell nuclear transfer (SCNT) rat embryos. Fetal fibroblast cells were isolated from a Day 14.5 fetus, and the oocytes for recipient cytoplasm were recovered from 4-week old Sprague Dawley rats. After enucleation and nuclear injection, the reconstructed oocytes were immediately exposed to activation medium consisting of 10 mM $SrCl_2$ with or without CB for 4 hr, and formation of pseudo-pronucleus (PPN) was checked at 18 hr after activation. Then, they were transferred into day 1 pseudopregnant recipients (Hooded Wistar) or cultured for 5 days to check their developmental competence in vivo or in vitro. The number of PPN was not affected by CB treatment during the activation. However, CB treatment supported pre-implantation development of rat SCNT embryos. Embryos generated by the procedures of SCNT were also capable of implanting, with 1 implantation scar found from a recipient following the transfer of 87 SCNT embryos to four foster mothers. The result of the present study shows that rat SCNT embryo can develop to post-implantation stage following treatment with CB.

Evaluation of Osseointegration around Tibial Implants in Rats by Ibandronate-Treated Nanotubular Ti-32Nb-5Zr Alloy

  • Nepal, Manoj;Li, Liang;Bae, Tae Sung;Kim, Byung Il;Soh, Yunjo
    • Biomolecules & Therapeutics
    • /
    • v.22 no.6
    • /
    • pp.563-569
    • /
    • 2014
  • Materials with differing surfaces have been developed for clinical implant therapy in dentistry and orthopedics. This study was designed to evaluate bone response to titanium alloy containing Ti-32Nb-5Zr with nanostructure, anodic oxidation, heat treatment, and ibandronate coating. Rats were randomly assigned to two groups for implantation of titanium alloy (untreated) as the control group and titanium alloy group coated with ibandronate as the experimental group. Then, the implants were inserted in both tibiae of the rats for four weeks. After implantation, bone implant interface, trabecular microstructure, mechanical fixation was evaluated by histology, micro-computed tomography (${\mu}CT$) and the push-out test, respectively. We found that the anodized, heat-treated and ibandronate-coated titanium alloy triggered pronounced bone implant integration and early bone formation. Ibandronate-coated implants showed elevated values for removal torque and a higher level of BV/TV, trabecular thickness and separation upon analysis with ${\mu}CT$ and mechanical testing. Similarly, higher bone contact and a larger percentage bone area were observed via histology compared to untreated alloy. Furthermore, well coating of ibandronate with alloy was observed by vitro releasing experiment. Our study provided evidences that the coating of bisphosphonate onto the anodized and heat-treated nanostructure of titanium alloy had a positive effect on implant fixation.

STABILITY OF SIMULTANEOUS IMPLANTATION WITH AUTOGENOUS ILIAC BONE GRAFT IN THE SEVERELY ATROPHIC MAXILLA (심하게 흡수된 상악골에서 자가 장골 이식술과 동시에 시행한 임프란트 치료의 안정성에 대한 연구)

  • Byun, June-Ho;Park, Bong-Wook;Jeong, Hee-Chan;Kim, Jong-Ryoul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.6
    • /
    • pp.570-578
    • /
    • 2006
  • A severely atrophic maxilla may disturb the proper implant placement. The various bone graft techniques are required for simultaneous or delayed implantation in the cases of atrophic alveolar ridges. We present 11 consecutive patients treated with simultaneous implantation using the autogenous inlay and/or onlay bone grafts from iliac crest to the floor of the maxillary sinus and the alveolar crest. In the cases of atrophic maxilla, a total 69 implants were simultaneously placed with autogenous iliac bone graft. 40 fixtures were inserted in the sinus floor simultaneously with subantral block bone graft, the other 29 fixtures were placed in the anterior or premolar areas with block or particulate bone graft. The vertical alveolar bone height was measured with Dental CT at the preoperation and 6 months postoperation. Moreover, the implant stability quotients (ISQ) were measured by $Osstell^{TM}$ during second implant surgery at 6 months later of first implantation. All implants were obtained successful osseointegration with the grafted bone. The mean vertical increases were 3.9mm in the anterior ridges and 12.8mm in the posterior ridges. During the second implant surgery, mean ISQ were 62.95 in the anterior ridge and 61.32 in the posterior ridge. We concluded that the simultaneous implantation with autogenous iliac bone graft were stable and available methods for severely atrophic maxilla.

하악골에 발생한 황문근육종의 일례보고

  • Bak, Chan-Wun
    • The Journal of the Korean dental association
    • /
    • v.18 no.5 s.134
    • /
    • pp.343-347
    • /
    • 1980
  • A case of 35-year-man with a rhabdomyosarcoma in the mandible has been presented. Chief complaints are dull sensation and growing mass at the area of the right mandible. In order to make diagnosis, roentgenograms were taken which revealed some sort of radiopaque and punched appearane at the area from right body to angle of the mandible, and biopsy was made, by which rhabdomyosarcoma was observed. The author treated this patient in terms of hemimandiblectomy, neck dissection and resin-made mandible implantation, and has observed this patient for two and half years after operation. The author satisfy that this patient has been recovered.

  • PDF

Management of peri-implantitis associated with tear-like implant fracture: case reports (열리형 임플란트 파절과 연관된 임플란트 주위염의 관리: 증례 보고)

  • Kim, Yeon-Tae;Lee, Jae-Hong;Jeong, Seong-Nyum
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.138-144
    • /
    • 2020
  • Implant fracture is rare, but one of the most serious problem in implantation. Treatment of implant fracture can be different according to the extent of the fracture and on the state of the surrounding prosthetic restoration. Maintaining or submerging implant after treatment of peri-implantitis can be useful options for cases of tear-like fracture on the coronal area of an implant.