• Title/Summary/Keyword: Dental Computer-Aided Design

Search Result 200, Processing Time 0.023 seconds

Comparison of crown designs of different dental occupational groups, using CAD-CAM (CAD-CAM을 이용하여 디자인한 금관의 치과 직업군에 따른 형태 비교)

  • Kim, TaeHyeon;Kim, Jong-Eun;Lee, Ah-Reum;Park, Young-Bum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.234-238
    • /
    • 2016
  • Purpose: Increasing use of computer aided design-computer aided manufacturing (CAD-CAM) system and number of design software made design of restoration easy and quick. Outcome of restoration has been dependent on dental technician's wax up proficiency, dentists can design restoration for themselves now. This study aims to investigate the outcome of restoration designs, according to handling skill of CAD-CAM design tool. Materials and methods: A patient's mandibular right 1st molar was prepared. After taking impression, stone model was made, scanned the stone model with 3 shape intra-oral scanner, stereolithography (STL) file was extracted. With 3shape dental designer, one dental technician with more than 5 years work experience (designer 0) and three dental technicians with less than 2years work experience (designer 1, 2, 3-group DT) and 4 1st year residents (designer 4, 5, 6, 7-group RT) designed gold crown on the same STL file. Designed crown's MD (mesio-distal) and BL (bucco-lingual) diameter, height of crown, inter-cuspal distance, number of occlusal contact points were compared. Statistical analysis was carried out, test of normality within each group, using independent t-test. Number of contact points were compared, using Wilcoxon signed-rank test. Results: There was no significant difference between group DT and group RT. Number of contact points also resulted in no significant difference. Conclusion: The outcome of each designed crowns showed no statistical differences, in values which can be expressed as numbers. Subjective factors were different. With increasing proficiency in handling designing software, fabrication of restorations according to each designer's occlusal concept can be made easy.

Chairside computer-aided design/computer-aided manufacturing (CAD/CAM)-based restoration of anterior teeth with customized shade and surface characterization: a report of 2 cases (CAD/CAM을 이용한 전치부 수복시 색조 및 표면 특성의 개별화를 시행한 증례)

  • Kim, Hyun-Jung;Jang, Ji-Hyun;Ryu, Gil-Joo;Choi, Kyoung-Kyu;Kim, Duck-Su
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.128-137
    • /
    • 2020
  • Over the last 30 years, the use of chairside computer-aided design (CAD) and computer-aided manufacturing (CAM) systems has evolved and has become increasingly popular in dentistry. Although CAD/CAM restorations have been used in the anterior dentition, satisfying the esthetic requirements of clinicians and patients, where the restorations are limited to the chairside, remains a challenge. To reproduce multi-shades of CAD/CAM restorations in the clinic, a preliminary experiment to express several shades on A2 lithium disilicate (LS2) blocks using a staining kit was performed. After measurement of the CIE L*a*b* value of specimens, it was compared with that of the commercial shade guide. This report presents two cases with individual customization of shade and surface characterization of the CAD/CAM restorations using predictable methods based on the preliminary experimental data. The anatomical shape of restoration was obtained from 'copy and paste technique' and 'mirror image acquisition technique'. All treatment procedures and fabrication of restorations performed in this report were executed in the clinic itself.

Sinus floor elevation and implant-supported fixed dental prosthesis in the posterior area, with full-digital system: a case report (완전 디지털 시스템을 이용한 상악동 거상술 및 구치부 임플란트 고정성 보철 수복 증례)

  • Gang Soo Park;Sunjai Kim;Se-Wook Pyo;Jae-Seung Chang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.157-164
    • /
    • 2024
  • A variety of digital technologies are being used throughout the entire implant treatment process of diagnosis, surgery, impression, design, and fabrication of prostheses. In this case, using a digital surgical guide, sinus floor elevation was performed without complications, and the implants were placed in the planned position. After the healing period for osseointegration, CAD-CAM (Computer-aided design-Computer-aided manufacturing) customized abutments and provisional prostheses were delivered. While using the provisional prosthesis, occlusal change was observed. To transfer the intermaxillary relationship and abutment position that reflect occlusal change and axial displacement, double scanning and abutment-level digital impressions were taken. Abutment superimposition was used to capture the subgingival margin without gingival retraction. Then, the definitive prosthesis was designed and fabricated with digital system. We report a case applying digital system, to achieve the predictable result as well as the efficient treatment process from implant surgery to fabricating prosthesis in the posterior area.

An alternative method to convert fractured metal ceramic surveyed crown into a complete contour zirconia surveyed crown using CAD-CAM technology under anticancer treatments: a clinical report (항암치료 중인 환자에서 파절된 금속-도재관을 CAD/CAM으로 제작된 complete contour zirconia surveyed crown(완전한 윤곽을 가진 지르코니아 써베이드 전장관) 보철 수복: 증례 보고)

  • Lee, Seon-Ki;Yang, Hong-So;Park, Sang-Won;Yun, Kwi-Dug;Lim, Hyun-Pil
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.1
    • /
    • pp.45-49
    • /
    • 2015
  • In this clinical report, a simple and convenient conversion of a fractured metal-ceramic surveyed crown into a complete contour zirconia surveyed crown by using computer-aided design and computer-aided manufacturing technology for an existing partial removable dental prosthesis is described. The duplication of the original contours, morphology, and the rest seat of the existing metal-ceramic surveyed crown, into a complete contour zirconia surveyed crown under anticancer treatments were reported.

Superimposition: a simple method to minimize occlusal adjustment of monolithic restoration (디지털 장비의 중첩기능을 이용하여 단일체 수복물의 교합조정을 최소화한 증례)

  • Choi, Changhun;Kim, Sunjai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.253-258
    • /
    • 2016
  • The development of translucent zirconia enabled clinicians to choose a monolithic zirconia crown as one treatment modality in the posterior dentition. Careful occlusal adjustments are recommended for monolithic zirconia crowns because grinding zirconia inevitably causes phase transformation, which may deteriorate mechanical properties. intraoral scanners enable the clinician to scan and superimpose a complete tooth structure before preparation onto the prepared abutment. This technique helps to reproduce the original tooth form and occlusion of the patient. In this case report, prostheses were fabricated for patients with cracked or fractured tooth by applying intraoral scanner, Computer aided design-computer aided manufacturing (CAD-CAM) and monolithic zirconia crown to reproduce the occlusion of original tooth and to minimize occlusal adjustment. The clinical results were satisfactory in both esthetic and functional aspects.

Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot

  • Choi, Kyu-Hyung;Son, KeunBaDa;Lee, Du-Hyeong;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.381-387
    • /
    • 2018
  • PURPOSE. Cement-retained implant prostheses can lack proper retrievability during repair, and residual cement can cause peri-implantitis. The purpose of this in vitro study was to evaluate the influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with lingual slots, known as retrievable cement-type slots (RCS). MATERIALS AND METHODS. We fabricated six types of titanium abutments (10 of each type) with two different heights (4 mm and 6 mm), three different convergence angles ($8^{\circ}$, $10^{\circ}$, and $12^{\circ}$), a sloped shoulder margin (0.6 mm depth), a rectangular shape ($6mm{\times}6.5mm$) with rounded edges, and a rectangular ledge ($2mm{\times}1mm$) for the RCS. One monolithic zirconia crown was fabricated for each abutment using a dental computer-aided design/computer-aided manufacturing system. The abutments and crowns were permanently cemented together with dual-curing resin cement, followed by 24 hours in demineralized water at room temperature. Using a custom-made device with a slot driver and torque gauge, we recorded the torque ($N{\cdot}cm$) required to remove the crowns. Statistical analysis was conducted using multiple regression analysis and Mann-Whitney U tests (${\alpha}=.05$). RESULTS. Removal torques significantly decreased as convergence angles increased. Multiple regression analysis showed no significant interaction between the abutment height and the convergence angle (Durbin-Watson ratio: 2.186). CONCLUSION. Within the limitations of this in vitro study, we suggest that the retrievability of cement-retained implant prostheses with RCS can be maintained by adjusting the abutment height and convergence angle, even when they are permanently cemented together.

CAD/CAM splint based on soft tissue 3D simulation for treatment of facial asymmetry

  • Tominaga, Kazuhiro;Habu, Manabu;Tsurushima, Hiroki;Takahashi, Osamu;Yoshioka, Izumi
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.4.1-4.6
    • /
    • 2016
  • Background: Most cases of facial asymmetry involve yaw deformity, and determination of the yaw correction level is very difficult. Methods: We use three-dimensional soft tissue simulation to determine the yaw correction level. This three-dimensional simulation is based on the addition of cephalometric prediction to gradual yaw correction. Optimal yaw correction is determined visually, and an intermediate splint is fabricated with computer-aided design and computer-aided manufacturing. Application of positioning devices and the performance of horseshoe osteotomy are advisable. Results: With this procedure, accurate repositioning of jaws was confirmed and patients obtained fairly good facial contour. Conclusions: This procedure is a promising method for a widespread, predictable treatment of facial asymmetry.

The reliability of an easy measuring method for abutment convergence angle with a computer-aided design (CAD) system

  • Seo, Yong-Joon;Kwon, Taek-Ka;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.3
    • /
    • pp.185-193
    • /
    • 2014
  • PURPOSE. The purpose of this study was to evaluate the intra-rater reliability and inter-rater reliability of three different methods using a drawing protractor, a digital protractor after tracing, and a CAD system. MATERIALS AND METHODS. Twenty-four artificial abutments that had been prepared by dental students were used in this study. Three dental students measured the convergence angles by each method three times. Bland-Altman plots were applied to examine the overall reliability by comparing the traditional tracing method with a new method using the CAD system. Intraclass Correlation Coefficients (ICC) evaluated intra-rater reliability and inter-rater reliability. RESULTS. All three methods exhibited high intra-rater and inter-rater reliability (ICC>0.80, P<.05). Measurements with the CAD system showed the highest intra-rater reliability. In addition, it showed improved inter-rater reliability compared with the traditional tracing methods. CONCLUSION. Based on the results of this study, the CAD system may be an easy and reliable tool for measuring the abutment convergence angle.

A Digital Approach to a Definitive Immediate Denture: A Clinical Report

  • Lee, Ju-Hyoung;Kim, Hyung Gyun
    • Journal of Korean Dental Science
    • /
    • v.9 no.2
    • /
    • pp.74-80
    • /
    • 2016
  • Even though an immediate denture (ID) is a practical prosthesis, fabricating an ID may be challenging, as unexpected removals of periodontally compromised teeth may occur during an impression procedure. This clinical report introduces a digital approach to a maxillary ID. An intraoral scanner was applied to prevent accidental extraction. A physical cast and a resin pattern of a framework were fabricated with rapid prototyping technology. A proper border and retention was also achieved by an altered cast impression.

Procera System : a Review of Literature (Procera System의 역사적 고찰)

  • Shin, Soo-yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.4
    • /
    • pp.309-315
    • /
    • 2006
  • The availability of high-technology systems that use computer-aided design(CAD) and computer-aided machining(CAM) is on the increase. One such system is the Procera system, which fabricates an all-ceramic crown composed of a densely sintered, high-purity aluminum oxide coping combined with a compatible veneering porcelain. Strength, precision of fit, esthetics, cementation, and biocompatibility are among the many factors that concern clinicians when fabricating all-ceramic restorations with this system. This paper reviews the long history and background development of technical, laboratory and clinical applications and presents, in summary form, the data from the many studies on the Procera system.