DOI QR코드

DOI QR Code

The reliability of an easy measuring method for abutment convergence angle with a computer-aided design (CAD) system

  • Seo, Yong-Joon (Department of Prosthodontics, Seoul National University School of Dentistry) ;
  • Kwon, Taek-Ka (Department of Dentistry, St. Catholic Hospital, Catholic University of Korea) ;
  • Han, Jung-Suk (Department of Prosthodontics, Seoul National University School of Dentistry) ;
  • Lee, Jai-Bong (Department of Prosthodontics, Seoul National University School of Dentistry) ;
  • Kim, Sung-Hun (Department of Prosthodontics, Seoul National University School of Dentistry) ;
  • Yeo, In-Sung (Department of Prosthodontics, Seoul National University School of Dentistry)
  • Received : 2013.10.17
  • Accepted : 2014.03.14
  • Published : 2014.06.30

Abstract

PURPOSE. The purpose of this study was to evaluate the intra-rater reliability and inter-rater reliability of three different methods using a drawing protractor, a digital protractor after tracing, and a CAD system. MATERIALS AND METHODS. Twenty-four artificial abutments that had been prepared by dental students were used in this study. Three dental students measured the convergence angles by each method three times. Bland-Altman plots were applied to examine the overall reliability by comparing the traditional tracing method with a new method using the CAD system. Intraclass Correlation Coefficients (ICC) evaluated intra-rater reliability and inter-rater reliability. RESULTS. All three methods exhibited high intra-rater and inter-rater reliability (ICC>0.80, P<.05). Measurements with the CAD system showed the highest intra-rater reliability. In addition, it showed improved inter-rater reliability compared with the traditional tracing methods. CONCLUSION. Based on the results of this study, the CAD system may be an easy and reliable tool for measuring the abutment convergence angle.

Keywords

References

  1. No authors listed. The glossary of prosthodontic terms. J Prosthet Dent 2005;94:10-92. https://doi.org/10.1016/j.prosdent.2005.03.013
  2. Jorgensen KD. The relationship between retention and convergence angle in cemented veneer crowns. Acta Odontol Scand 1955;13:35-40. https://doi.org/10.3109/00016355509028171
  3. Kaufman EG, Coelho DH, Colin L. Factors influencing the retention of cemented gold castings. J Prosthet Dent 1961; 11:487-502. https://doi.org/10.1016/0022-3913(61)90232-3
  4. Goodacre CJ, Campagni WV, Aquilino SA. Tooth preparations for complete crowns: an art form based on scientific principles. J Prosthet Dent 2001;85:363-76. https://doi.org/10.1067/mpr.2001.114685
  5. Wilson AH Jr, Chan DC. The relationship between preparation convergence and retention of extracoronal retainers. J Prosthodont 1994;3:74-8. https://doi.org/10.1111/j.1532-849X.1994.tb00132.x
  6. Weed RM. Determining adequate crown convergence. Tex Dent J 1980;98:14-6.
  7. Al-Omari WM, Al-Wahadni AM. Convergence angle, occlusal reduction, and finish line depth of full-crown preparations made by dental students. Quintessence Int 2004;35:287-93.
  8. el-Ebrashi MK, Craig RG, Peyton FA. Experimental stress analysis of dental restorations. VI. The concept of proximal reduction in compound restorations. J Prosthet Dent 1969; 22:663-70. https://doi.org/10.1016/S0022-3913(69)80010-7
  9. Weed RM, Baez RJ. A method for determining adequate resistance form of complete cast crown preparations. J Prosthet Dent 1984;52:330-4. https://doi.org/10.1016/0022-3913(84)90437-2
  10. Lewis RM, Owen MM. A mathematical solution of a problem in full crown construction. J Am Dent Assoc 1959;59: 943-7. https://doi.org/10.14219/jada.archive.1959.0249
  11. Shillingburg HT, Hobo S, Whitsett LD, Brackett SE. Fundamentals of fixed prosthodontics. In Bateman LA, eds. Principles of tooth preparations. 3rd ed. Chicago; Quintessence Pub. Co.; 1997. p 119-38.
  12. Chandra Shekar S, Giridhar K, Suhas Rao K. An in vitro study to evaluate the retention of complete crowns prepared with five different tapers and luted with two different cements. J Indian Prosthodont Soc 2010;10:89-95. https://doi.org/10.1007/s13191-010-0017-x
  13. Annerstedt A, Engstrom U, Hansson A, Jansson T, Karlsson S, Liljhagen H, Lindquist E, Rydhammar E, Tyreman- Bandhede M, Svensson P, Wandel U. Axial wall convergence of full veneer crown preparations. Documented for dental students and general practitioners. Acta Odontol Scand 1996; 54:109-12. https://doi.org/10.3109/00016359609006014
  14. Mack PJ. A theoretical and clinical investigation into the taper achieved on crown and inlay preparations. J Oral Rehabil 1980;7:255-65. https://doi.org/10.1111/j.1365-2842.1980.tb00443.x
  15. Ohm E, Silness J. The convergence angle in teeth prepared for artificial crowns. J Oral Rehabil 1978;5:371-5. https://doi.org/10.1111/j.1365-2842.1978.tb01256.x
  16. Leempoel PJ, Lemmens PL, Snoek PA, van 't Hof MA. The convergence angle of tooth preparations for complete crowns. J Prosthet Dent 1987;58:414-6. https://doi.org/10.1016/0022-3913(87)90265-4
  17. Smith CT, Gary JJ, Conkin JE, Franks HL. Effective taper criterion for the full veneer crown preparation in preclinical prosthodontics. J Prosthodont 1999;8:196-200. https://doi.org/10.1111/j.1532-849X.1999.tb00035.x
  18. Velasquez-Plata D, Andres CJ. The art of crown preparation: a review of principles. J Indiana Dent Assoc 1996;75:6-11.
  19. Ayad MF, Maghrabi AA, Rosenstiel SF. Assessment of convergence angles of tooth preparations for complete crowns among dental students. J Dent 2005;33:633-8. https://doi.org/10.1016/j.jdent.2004.12.008
  20. Dodge WW, Weed RM, Baez RJ, Buchanan RN. The effect of convergence angle on retention and resistance form. Quintessence Int 1985;16:191-4.
  21. Nordlander J, Weir D, Stoffer W, Ochi S. The taper of clinical preparations for fixed prosthodontics. J Prosthet Dent 1988; 60:148-51. https://doi.org/10.1016/0022-3913(88)90304-6
  22. Noonan JE Jr, Goldfogel MH. Convergence of the axial walls of full veneer crown preparations in a dental school environment. J Prosthet Dent 1991;66:706-8. https://doi.org/10.1016/0022-3913(91)90457-8
  23. Kent WA, Shillingburg HT Jr, Duncanson MG Jr. Taper of clinical preparations for cast restorations. Quintessence Int 1988;19:339-45.
  24. Okuyama Y, Kasahara S, Kimura K. Quantitative evaluation of axial wall taper in prepared artificial teeth. J Oral Sci 2005; 47:129-33. https://doi.org/10.2334/josnusd.47.129
  25. Dorriz H, Nokar S, Baghai Naini R, Madadi A. The convergence angle of full-coverage crown preparations made by dental students. J Dent Tehran Univ Med Sci 2008;5:37-41.
  26. de Vet HC, Terwee CB, Knol DL, Bouter LM. When to use agreement versus reliability measures. J Clin Epidemiol 2006; 59:1033-9. https://doi.org/10.1016/j.jclinepi.2005.10.015
  27. Shrout PE, Fleiss JL. Intraclass correlations: uses in assessing rater reliability. Psychol Bull 1979;86:420-8. https://doi.org/10.1037/0033-2909.86.2.420
  28. Weir JP. Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. J Strength Cond Res 2005;19:231-40.
  29. Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics 1977;33:159-74. https://doi.org/10.2307/2529310

Cited by

  1. Convergence Angles of Clinical Tooth Preparations for Metal Ceramic Restorations Among Dental Students and General Practitioners vol.9, pp.2, 2014, https://doi.org/10.5812/ajdr.13106