• Title/Summary/Keyword: Density gradient

Search Result 645, Processing Time 0.027 seconds

Closed-form Expressions of Magnetic Field and Magnetic Gradient Tensor due to a Circular Disk (원판형 이상체에 의한 자력 및 자력 변화율 텐서 반응식)

  • Rim, Hyoungrea
    • Geophysics and Geophysical Exploration
    • /
    • v.25 no.1
    • /
    • pp.38-43
    • /
    • 2022
  • In case axial symmetrical bodies with varying cross sections such as volcanic conduits and unexploded ordnance (UXO), it is efficient to approximate them by adding the response of thin disks perpendicular to the axis of symmetry. To compute the vector magnetic and magnetic gradient tensor respones by such bodies, it is necessary to derive an analytical expression of the circular disk. Therefore, in this study, we drive closed-form expressions of the vector magnetic and magnetic gradient tensor due to a circular disk. First, the vector magnetic field is obtained from the existing gravity gradient tensor using Poisson's relation where the gravity gradient tensor due to the same disk with a constant density can be transformed into a magnetic field. Then, the magnetic gradient tensor is derived by differentiating the vector magnetic field with respect to the cylindrical coordinates converted from the Cartesian coordinate system. Finally, both the vector magnetic and magnetic gradient tensors are derived using Lipschitz-Hankel type integrals based on the axial symmetry of the circular disk.

Application Method of GIS for Planning of Forest Road Network (임도망의 계획에 있어서 GIS 활용방안)

  • Jeon, Kwon-Seok;Ma, Ho-Seop
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.5 no.3
    • /
    • pp.99-106
    • /
    • 2002
  • The application method of GIS for planning of forest road network can be save the efforts and cost by frequently change of forest road and evaluation the forest road route before construction. The purpose of this study is to suggest the proper method for planning an optimal forest road network in mountains forest using geographic information system(GIS) in the national forest of Mt. Kumsan at Namhae-gun, Gyungsangnam-do. In the forest road network planning by the minimum longitudinal gradient, The total length was 20.41km, and road density was 6.92m/ha. In the forest road network planning by mixed with the minimum longitudinal gradient and the maximization of investment effect, The total length was 21.15km, and road density was higher than that of the minimum longitudinal gradient as 7.17m/ha. The road length overlapped by cost path was more short than 3.52m/ha of the minimum longitudinal gradient as 1.73km. So, it appeared that forest road has an high effectiveness in yarding function. Therefore, it considered that the geographic information system could provide an effective and resonable solutions for planning of optimal forest road network.

  • PDF

Characterization of Polypeptides From Human Serum Very Low Density Lipoproteins by Isoelectric Focusing Fractionation (등전점초점(等電點焦點) 맞추기 획분법(劃分法)에 의(依)한 극저밀도(極低密度) 혈청(血淸) 지단백질(脂蛋白質) Polypeptide의 특성(特性))

  • Lim, Chang-Taik
    • Applied Biological Chemistry
    • /
    • v.16 no.3
    • /
    • pp.112-117
    • /
    • 1973
  • The very low density apolipoproteins were separated by a newly developed method of isoelectric focusing in a narrow pH gradient. Four polypeptides were isolated that differed from the major proteins of the high density or low density lipoproteins. Three of these proteins had indistinguishable amino acid compositions, but different isoelectric points, COOH-terminal alanine, no isoleucine, cysteine or cystine. Two of these polypeptides had $NH_2-terminal$ serine. The polymorphism of apolipoprotein-Ala, so designated from the COOH-terminal residue, was related to sialic acid content; one form contained 2 moles of sialic acid per mole of protein, the second, 1 mole of protein, and the third, no sialic acid. The fourth polypeptide had an amino acid composition different from the first three polypeptides and from other polypetides obtained from very low density lipoprotein. This polypeptide had $NH_2-terminal$ threonine, COOH-terminal resistant to carboxypeptidase A, no histidine, cysteine, cystine or sialic acid. These four polypeptides constituted approx. 40% of the total protein in very low density lipoprotein.

  • PDF

Studies of Density-Fractionated Human Ervthrocvte Membranes (농도분배에 따라 분리한 사람 적혈구 막에 관한 연구)

  • 정종문
    • The Korean Journal of Zoology
    • /
    • v.37 no.4
    • /
    • pp.597-604
    • /
    • 1994
  • Membranes obtained from the normal human RBC population were separated by continuous sucrose density gradient centrifugation and the density-fractionated membranes were then examined for changes in molecular markers. This study focuses on changes of (i) the membrane protein profile, (ii) differences in membrane-associsted enzyme activities, and (iii) the amount of autologous IgG bound. The following observations were made: (i) ratios for band 4. la over the sum of bands (4. la + 4.Ib) ranged from 0.58 to 0.79 for membranes of lowest density; (ii) significant changes in bound glyceraldehyde-3-phosphate dehydrogenase and acetvlcholinesterase activities were found; (iii) the amounts of autolosous IgG's attached to the red blood cells was highest in the membrane fraction of lowest density.

  • PDF

Microfluidic immunoassay using superparamagnetic nanoparticles in an enhanced magnetic field gradient (강화된 자기장 구배 하에서 나노자성입자를 이용한 미세유체 기반의 면역 측정)

  • Hahn, Young-Ki;Kang, Joo-H.;Kim, Kyu-Sung;Park, Je-Kyun
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.158-163
    • /
    • 2006
  • This paper reports a novel immunoassay method using superparamagnetic nanoparticles and an enhanced magnetic field gradient for the detection of protein in a microfluidic device. We use superparamagnetic nanoparticles as a label and fluorescent polystyrene beads as a solid support. Based on this platform, magnetic force-based microfluidic immunoassay is successfully applied to analyze the concentration of IgG as model analytes. In addition, we present ferromagnetic microstructure connected with a permanent magnet to increase magnetic flux density gradient (dB/dx, ${\sim}10^{4}$ T/m), which makes limit of detection reduced. The detection limit is reduced to about 1 pg/mL.

Frequency domain analysis of the urophonography for LUTS diagnosis (하부요로 폐색 진단을 위한 요류음 주파수 분석)

  • Jeong, Do-Un;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.202-210
    • /
    • 2007
  • The aim of this study is to acquire useful information of lower urinary tract symptom (LUTS) diagnosis through urophonography signal as a noninvasive method. The hardware and software which could evaluate the function of compensatory hypertrophy with noninvasive and comfortable method was implemented to measure uroflow and urophonography signal during urination. The PSD (power spectrum density) and the log-log plot gradient analysis were accomplished in frequency domain. For evaluation of the system and analysis method, a model system for the lower urinary system of men was used. From the evaluation of the model system, the PDS and the log-log plot gradient were dependent on the occlusion degree significantly. In a pilot study on normal and abnormal male subjects, the PSD and the log-log plot gradient were highly correlated with the artificial urethral obstruction.

Two-Paralleled PWM Power Amplifiers to Generate Highly Precise Gradient Magnetic Fields in MRI Systems

  • Watanabe, Shuji;Boyagoda, Prasanna;Takano, Hiroshi;Nakaoka, Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.569-574
    • /
    • 1998
  • This paper presents a two-paralleled 4 quadrant DC chopper type PWM power conversion circuit in order to generate a gradient magnetic field in the Magnetic Resonance Imaging (MRI) system. This power amplifier is connected in parallel with the conventional 4-quadrant DC chopper using IGBTs at their inputs/outputs to realize further high-power density, high speed current tracking control, and to get a low switching ripple amplitude in a controlled current in the Gradient Coils (GCs). Moreover, the power conversion circuit has to realize quick rise/fall response characteristics in proportion to various target currents in GCs. It is proposed in this paper that a unique control scheme can achieve the above objective. DSP-based control systems realize a high control facility and accuracy. It is proved that the new control system will greatly enlarge the diagnostic target and improve the image quality of MRI.

  • PDF

Analysis for Cracks of Functionally Gradient Materials by Photoelastic Experiment (광탄성실험에 의한 함수구배 재료 균열 해석)

  • Lee, Kwang-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.48-53
    • /
    • 2004
  • This paper suggested the method determing the stress intensity factor (SIF) for functionally gradient materials (FGMs) by photo elastic experimental method. The SIF for the center crack in a finite rectangulat plate with a linear variation of shear modulus with constant density and Poisson's ratio along the direction of the crack under mode I static loading is obtained. The exponential and linear variation of stress fields are used for obtaining the SIF. The greater crack length, the increaser the difference of the SIF between right and left side crack tip.

  • PDF

Dispersion of waves in FG porous nanoscale plates based on NSGT in thermal environment

  • Ebrahimi, Farzad;Seyfi, Ali;Dabbagh, Ali
    • Advances in nano research
    • /
    • v.7 no.5
    • /
    • pp.325-335
    • /
    • 2019
  • In the present study, nonlocal strain gradient theory (NSGT) is developed for wave propagation of functionally graded (FG) nanoscale plate in the thermal environment by considering the porosity effect. $Si_3N_4$ as ceramic phase and SUS304 as metal phase are regarded to be constitutive material of FG nanoplate. The porosity effect is taken into account on the basis of the newly extended method which considers coupling influence between Young's modulus and mass density. The motion relation is derived by applying Hamilton's principle. NSGT is implemented in order to account for small size effect. Wave frequency and phase velocity are obtained by solving the problem via an analytical method. The effects of different parameters such as porosity coefficient, gradient index, wave number, scale factor and temperature change on phase velocity and wave frequency of FG porous nanoplate have been examined and been presented in a group of illustrations.

Development of novel magnetic filter for paramagnetic particles in high gradient magnetic separation

  • Nishijima, Shigehiro;Nomura, Naoki
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.3
    • /
    • pp.7-11
    • /
    • 2022
  • We are conducting research and development of magnetic filters for magnetic separation targeting paramagnetic materials. In order to develop a new magnetic filter with a large magnetic gradient, stainless fiber (SUS430, 120 mm × 3 mm) with a triangular cross section was sintered with a high void ratio (~ 70%) and the magnetic filter (20 mm × 2 mm) was created. When this magnetic filter was used to perform magnetic separation of hematite (particle size 50 ㎛) under a maximum magnetic flux density of 1.49 T, high separation rates were obtained.