• 제목/요약/키워드: Demonstration test

검색결과 412건 처리시간 0.032초

KIER의 열분해유화 공정 기술과 실증플랜트 소개 (Introduction of KIER Pyrolysis Process and 3,000 ton/yr Demonstration Plant)

  • 신대현;전상구;김광호;이경환;노남선;이기봉
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.479-482
    • /
    • 2008
  • Since late of 2000, KIER has developed a novel pyrolysis process for production of fuel oils from polymer wastes. It could have been possible due to large-scale funding of the Resource Recycling R&D Center. The target was to develop an uncatalyzed, continuous and automatic process producing oils that can be used as a fuel for small-scale industrial boilers. The process development has proceeded in three stages bench-scale unit, pilot plant and demonstration plant. As a result, the demonstration plant having capacity of 3,000 tons/year has been constructed and is currently under test operation for optimization of operation conditions. The process consisted of four parts ; feeding system, cracking reactor, refining system and others. Raw materials were pretreated via shredding and classifying to remove minerals, water, etc. There were 3 kind of products, oils(80%), gas(15%), carbonic residue(5%). The main products i.e. oils were gasoline and diesel. The calorific value of gas has been found to be about 18,000kcal/$m^3$ which is similar to petroleum gas and shows that it could be used as a process fuel. Key technologies adopted in the process are 1) Recirculation of feed for rapid melting and enhancement of fluidity for automatic control of system, 2) Tubular reactor specially-designed for heavy heat flux and prevention of coking, 3)Recirculation of heavy fraction for prevention of wax formation, and 4) continuous removal & re-reaction of sludge for high yield of main product (oil) and minimization of residue. The advantages of the process are full automation, continuous operation, no requirement of catalyst, minimization of coking and sludge problems, maximizing the product(fuel oil) yield and purity, low initial investment and operation costs and environment- friendly process. In this presentation, background of pyrolysis technology development, the details of KIER pyrolysis process flow, key technologies and the performances of the process will be discussed in detail.

  • PDF

KOGAS DME 공정의 실증 시험을 통한 최적화 기술개발 (Optimization of KOGAS DME Process From Demonstration Long-Term Test)

  • 정종태;조원준;백영순;이창하
    • 한국수소및신에너지학회논문집
    • /
    • 제23권5호
    • /
    • pp.559-571
    • /
    • 2012
  • Dimethyl ether (DME) is a new clean fuel as an environmentally-benign energy resource. DME can be manufactured from various energy sources including natural gas, coal, and biomass. In addition to its environmentally friendly properties, DME has similar characteristics to those of LPG. The aim of this article is to represent the development of new DME process with KOGAS's own technologies. KOGAS has investigated and developed new innovative DME synthesis process from synthesis gas in gaseous phase fixed bed reactor. DME has been traditionally produced by the dehydration of methanol which is produced from syngas, a product of natural gas reforming. This traditional process is thus called the two-step method of preparing DME. However, DME can also be manufactured directly from syngas (single-step). The single-step method needs only one reactor for the synthesis of DME, instead of two for the two-step process. It can also alleviate the thermodynamic limitations associated with the synthesis of methanol, by converting the produced methanol into DME, thereby potentially enhancing the overall conversion of syngas into DME. KOGAS had launched the 10 ton/day DME demonstration plant project in 2004 at Incheon KOGAS LNG terminal. In the mid of 2008, KOGAS had finished the construction of this plant and has successively finished the demonstration plant operation. And since 2008, we have established the basic design of commercial plant which can produce 3,000 ton/day DME.

중등 과학과 교사임용시험의 교과교육학 시험 개선 방안 탐색 (Exploring Ways to Improve Science Education Area Exam in Secondary School Teacher Employment Test)

  • 곽영순
    • 한국과학교육학회지
    • /
    • 제40권1호
    • /
    • pp.89-96
    • /
    • 2020
  • 본 연구에서는 현행 중등 과학과 교사임용시험의 2차 교과교육학 시험의 특징과 개선 방안을 탐구하였다. 임용시험 2차 교과교육학 시험인 교수학습지도안 작성 평가, 수업실연 평가, 교직적성 심층면접 평가, 과학실험시험 등을 중심으로 1차 지필시험과 차별화하면서 2차 실습형 과학교육학 시험의 개선 방안을 탐색하였다. 주요 연구결과로는 교수학습지도안 평가의 경우 1차 지필시험과는 평가초점이 달라서 2차 교수학습지도안 시험을 유지하되, 교수학습지도안 작성의 배점을 줄이고 수업실연의 비중을 높이는 방안 등을 제안하였다. 수업실연 평가의 경우 교사양성과정에서 수업실연을 학점화하여 임용시험에 반영하는 방안, 교육실습이나 실제 수업 상황에서 평가하는 방안, 교과 수업전문성에 초점을 두고 수업실연을 평가할 필요성 등을 제안하였다. 과학실험시험의 경우 모든 시·도교육청에서 과학실험시험을 필수화하고, 실험설계 능력과 실험기반 과학탐구 지도 능력 등을 평가할 필요성 등을 제안하였다. 연구결과를 토대로 수업실연이나 심층면접 등을 시·도교육청에서 자체 출제하는 방안, 수습교사제도 도입의 필요성, 교육전문대학원 도입 방안 등을 제언하였다.

태양열 냉.난방 및 급탕 시스템 열성능 (Evaluation of thermal performance for solar cooling and heating system)

  • 곽희열;주홍진;이호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.203-208
    • /
    • 2009
  • This paper presents demonstration study results derived through field testing of a solar assisted cooling and heating system for the library of a cultural center building located in Gwangju, Korea. The area of demanded cooling and heating for building was about 350m2. Solar hot water was delivered by means of a 200m2 array of evacuated tubular solar collector (ETSC) to drive a single-effect (LiBr/H2O) absorption chiller of 10RT nominal cooling capacity. From March in 2008 to February in 2009, demonstration test were performed for solar cooling and heating system. After experiments and analysis, this study found that solar thermal system was 84% for the solar hot water supply and 12% for space heating and 4% for space cooling.

  • PDF

배전용 STATCON 설치 사례-설치 및 평가 (Field Demonstration of the Distribution STATCON-Installation & Evaluation)

  • 차재덕;김준모;홍순욱;이학성;이기선;오관일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2641-2643
    • /
    • 1999
  • This paper describes the first field demonstration of the distribution STATCON in Korea including installation and its evaluation for improving power quality in distribution system. The purpose of installation is to verify functionally the voltage source inverter based equipment for voltage regulation and harmonic mitigation in distribution line. The operational data resulting from field test and the site figure are included.

  • PDF

사용후핵연료 차세대관리공정 운반취급계통 분석 (Analysis of Transportation and Handling system for Advanced spent fuel management process)

  • 홍동희;윤지섭;정재후;김영환;박병석;박기용;진재현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1438-1441
    • /
    • 2003
  • The project for "Development of Advanced Spent Fuel Management Technology" has a plan of a demonstration for the Advanced Management Process in the hot cell of IMEF. The Advanced Management Process are being developed for efficient and safe management of spent fuels. For the demonstration, several devices which are used to safely transport and handle nuclear materials without scattering have been derived by analyzing the Advanced Management Process, object nuclear material and modules of process equipment and performing graphical simulation of transportation/handling by computers. For verification, powder transportation vessel and handling device have been designed and manufactured. And several tests such as transporting, grappling, rotating the vessel have been performed. Also, the design requirements of transportation/handling equipment have been analyzed based on test results and process studies. The developed design requirements in this research will be used as the design data for the Advanced Management Process.

  • PDF

10kW급 지붕재용 태양전지모듈 실증연구 (Demonstration Study of 10kW Poly Metal Panel integrated PV Module)

  • 이소미;노지희;주만식
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.246-249
    • /
    • 2007
  • The application of photovoltaics into building as integrated building components has been paid more attention worldwide. Photovoltaics or solar electric modules are sol id state devices, directly converting solar radiation into electricity; the process does not require fuel and any moving parts, and produce no pollutants. And the prefab building method is very effective because the pre- manufactured building components is simply assembled to making up buildings in the construction fields especially the sandwich panel. So, this paper describes a design and performance test of the 10kW poly metal pv module(pmpp) system. It is concluded that the prediction of BIPV system's performance should be based on the more accurate PV module installation.

  • PDF

뇌졸중 환자의 주간호제공자를 위한 비디오재활교육의 효과 (Effects of Video-guided Education for Primary Family-caregivers of Stroke Patients)

  • 조복희
    • 기본간호학회지
    • /
    • 제18권2호
    • /
    • pp.237-246
    • /
    • 2011
  • Purpose: Family-caregivers of stroke patients usually go through hardship and life style changes during the protracted course of a family member's rehabilitation. There is need for programs to educate family-caregivers to better manage the medical crisis. In this study an evaluation was done of the degrees of burden and well-being experienced by primary family-caregivers following video-guided education (VGE) on rehabilitation and family lifestyle changes. Method: Fifty-eight primary family-caregivers of stroke patients on a neurological ward were divided into VGE (29) and control (29) groups. VGE was started within 7 days of patient admission. Interventions included VGE, counseling, and demonstration - re-demonstration. The control group received standard education but not VGE. Data were analyzed using Chi-square test, t-test, ANCOVA, and Pearson correlation coefficients with the SAS program. Results: The VGE group had a significantly lower score for total burden (F=7.19, p=.010) and for sub-scale of time-dependent burden (F=8.44, p=.005) than the control group. There was a negative correlation between primary family-caregiver burden and well-being (r=-.7151, p<.001). Conclusion: Results suggest that the rehabilitation program using VGE was an effective nursing intervention to reduce the burden of primary family-caregivers of stroke patients.

BIPV시스템의 건물적용 실증에 대한 구성요소별 발전성능 분석 (A study on the performance of various BIPV modules applied in a real building demonstration)

  • 이상문;허정호
    • 한국태양에너지학회 논문집
    • /
    • 제36권2호
    • /
    • pp.53-63
    • /
    • 2016
  • Building Integrated Photovoltaic (BIPV) is one of the best ways to generate electric power using the solar energy, which is clean and inexhaustible energy resources. The most of BIPV modules have the form of GtoG (Glass to Glass) photovoltaic in building applications. Degradation leading to failure in photovoltaic modules is very important factor in BIPV modules. This paper analyzed the performance of various BIPV modules through outdoor exposure tests. Performance of three BIPV modules(c-Si type, a-Si type and DSSC type) with three installation angles influenced by sun light, outdoor temperature, and wind velocity was monitored and analyzed. As a result, c-Si type BIPV module outperforms other BIPV modules(a-Si type). In terms of power efficiency of the module, the installed angle of $45^{\circ}$ is better than others(90 degree, 0 degree). In addition, more realistic data of various BIPV system performance could be available through the field test and integrated building test. In this study, relationship of the BIPV system is identified module's installation angle, power generation, architectural performance, etc.