• 제목/요약/키워드: Delta-1

검색결과 5,380건 처리시간 0.034초

INJECTIVELY DELTA CHOOSABLE GRAPHS

  • Kim, Seog-Jin;Park, Won-Jin
    • 대한수학회보
    • /
    • 제50권4호
    • /
    • pp.1303-1314
    • /
    • 2013
  • An injective coloring of a graph G is an assignment of colors to the vertices of G so that any two vertices with a common neighbor receive distinct colors. A graph G is said to be injectively $k$-choosable if any list $L(v)$ of size at least $k$ for every vertex $v$ allows an injective coloring ${\phi}(v)$ such that ${\phi}(v){\in}L(v)$ for every $v{\in}V(G)$. The least $k$ for which G is injectively $k$-choosable is the injective choosability number of G, denoted by ${\chi}^l_i(G)$. In this paper, we obtain new sufficient conditions to be ${\chi}^l_i(G)={\Delta}(G)$. Maximum average degree, mad(G), is defined by mad(G) = max{2e(H)/n(H) : H is a subgraph of G}. We prove that if mad(G) < $\frac{8k-3}{3k}$, then ${\chi}^l_i(G)={\Delta}(G)$ where $k={\Delta}(G)$ and ${\Delta}(G){\geq}6$. In addition, when ${\Delta}(G)=5$ we prove that ${\chi}^l_i(G)={\Delta}(G)$ if mad(G) < $\frac{17}{7}$, and when ${\Delta}(G)=4$ we prove that ${\chi}^l_i(G)={\Delta}(G)$ if mad(G) < $\frac{7}{3}$. These results generalize some of previous results in [1, 4].

고압하에서 염화벤질의 가용매분해반응에 대한 속도론적 연구 (A Kinetic Study on the Solvolysis of Benzyl Chloride under High Pressure)

  • 권오천;경진범
    • 대한화학회지
    • /
    • 제31권3호
    • /
    • pp.207-214
    • /
    • 1987
  • 염화벤질의 가용매분해반응에 대한 속도를 $1{\sim}1600bar$ 압력범위까지 변화시켜 가면서 온도 30 및 $40^{\circ}C$에서 측정하였다. In k대 압력의 실험결과는 압력에 따라 이차함수형으로 변화하였으며, 이로부터 활성화부피(${\Delta}V^{\neq}$)와 활성화 압축율(${\Delta}{\beta}^{\neq}$)의 값을 얻었다. In k를 용매파라미터($Q_w$) 및 ln $C_w$의 함수로 도시한 결과 이들 사이의 관계는 본 연구의 반응이 $S_N$1메카니즘으로 진행됨을 나타내었다. 이 전에 연구된 결과들과 비교한 결과 ${\mid}{{\Delta}V_0}^{\neq}{\mid}$와 n 값의 증가 순은 각각 p-Cl>p-H>p-$CH_3\;와\;p-$CH_3>p-H>p-Cl$이었다. 이로부터 $p-CH_3$ 치환체는 $S_N1(1)$ 성격이 강하며, 반면 p-Cl는 ${S_N}1(2)$ 성격이 나타남을 알았다.

  • PDF

Ni(II)-거대고리 리간드 착이온 ($NiL_m{^{2+}}$) 과 $CN^-$ 이온간의 반응성 (Chemical Reactivity between Ni(II)-Macrocycle Complex Ions ($NiL_m{^{2+}}$) and $CN^-$)

  • 박유철;변종철
    • 대한화학회지
    • /
    • 제31권4호
    • /
    • pp.334-343
    • /
    • 1987
  • $NiL_m{^{2+}}$착이온 {$Ni(rac-1[14]7-diene)^{2+},\;Ni(meso-1[14]7-diene)^{2+},\;Ni(1[14]4-diene)^{2+},\;{\alpha}-Ni(rac-[14]-decane)^{2+},\;{\beta}-Ni(rac-[14]-decane)^{2+},\;and\;Ni(meso-[14]-decane)^{2+}$}과 $CN^-$이온 사이의 화학반응은 분광광도법으로 연구하였다. $NiL_m{^{2+}}$착이온과 $CN^-$이온으로부터 1:1착이온, $[NiLm(CN)]^+$생성반응의 평형상수$(K_1)$는 3 ~ $25^{\circ}C$ 범위에서 결정되었다. $NiL_m{^{2+}}$착이온이 $Ni(rac-1[14]7-diene)^{2+},\;Ni(meso-1[14]7-diene)^{2+},\;Ni(1[14]4-diene)^{2+},\;{\alpha}-Ni(rac-[14]-decane)^{2+},\;{\beta}-Ni(rac-[14]-decane)^{2+}$, 그리고 $Ni(meso-[14]-decane)^{2+}$일때 평형상수($K_1$)은 $15^{\circ}C$에서 각각 4.7, 5.3, 6.2, 7.5, 9.4, 및 9.8이었다. $K_1$값은 온도가 증가함에 따라 감소하였다. $K_1$에 대한 온도영향으로 부터 열역학적 파라메터 $({\Delta}G^{\circ},\;{\Delta}H^{\circ},\;{\Delta}S^{\circ})$를 계산하였으며, 이 결과 $[NiLm(CN)]^+$ 생성반응은 모두 발열반응으로 나타났다. $NiL_m{^{2+}}$ 착이온과 $CN^-$이온은 반응하여 Ni(CN)_4{^{2-}}$이온과 거대고리 리간드 (Lm)가 생성된다. $[CN^-],\;[HCN],\;and\;[OH^-]$ 변화에 따라 $Ni(CN)_4{^{2-}}$이온의 생성속도는 0.5M $NaClO_4$, 온도 3∼$25^{\circ}C$ 범위에서 연구되었다. $[CN^-]$가 일정할 때 [HCN]가 증가하면 $k_{obs}/[CN^-]^2$값은 선형으로 증가하였다. $OH^-$ 이온이 과량으로 존재할 때 [$OH^-$]에 따라 역시 $k_{obs}/[CN^-]^2$ 값은 선형으로 증가하였다. $NiL_m{^{2+}}$ 착이온과 $CN^-$이온 반응의 속도상수($k_{obs}$)에 대한 온도영향으로 부터 활성화 파라메터$({\Delta}H^{\neq},\;{\Delta}S^{\neq})$를 결정하였다. $Ni(rac-1[14]7-diene)^{2+},\;Ni(meso-1[14]7-diene)^{2+},\;{\alpha}-Ni(rac-[14]-decane)^{2+},\;{\beta}-Ni(rac-[14]-decane)^{2+}$, 그리고 $Ni(meso-[14]-decane)^{2+}$ 순서로 d-d 전이에너지, $ν(cm^{-1})$가 감소할수록, ${\Delta}H^{\neq}$도 점차적으로 감소하였다. 그리고 5가지의 $NiL_m{^{2+}}$ 착이온과 $CN^-$이온 사이의 반응은 동일한 경로로 반응이 진행되었다.

  • PDF

GENERALIZED Δ-COHERENT PAIRS

  • Kwon, K.H.;Lee, J.H.;F. Marcellan
    • 대한수학회지
    • /
    • 제41권6호
    • /
    • pp.977-994
    • /
    • 2004
  • A pair of quasi-definite linear functionals {u$_{0}$, u$_1$} is a generalized $\Delta$-coherent pair if monic orthogonal polynomials (equation omitted) relative to u$_{0}$ and u$_1$, respectively, satisfy a relation (equation omitted) where $\sigma$$_{n}$ and T$_{n}$ are arbitrary constants and $\Delta$p = p($\chi$+1) - p($\chi$) is the difference operator. We show that if {u$_{0}$, u$_1$} is a generalized $\Delta$-coherent pair, then u$_{0}$ and u$_{1}$ must be discrete-semiclassical linear functionals. We also find conditions under which either u$_{0}$ or u$_1$ is discrete-classical.ete-classical.

COMPOSITION OPERATORS ON THE PRIVALOV SPACES OF THE UNIT BALL OF ℂn

  • UEKI SEI-ICHIRO
    • 대한수학회지
    • /
    • 제42권1호
    • /
    • pp.111-127
    • /
    • 2005
  • Let B and S be the unit ball and the unit sphere in $\mathbb{C}^n$, respectively. Let ${\sigma}$ be the normalized Lebesgue measure on S. Define the Privalov spaces $N^P(B)\;(1\;<\;p\;<\;{\infty})$ by $$N^P(B)\;=\;\{\;f\;{\in}\;H(B) : \sup_{0 where H(B) is the space of all holomorphic functions in B. Let ${\varphi}$ be a holomorphic self-map of B. Let ${\mu}$ denote the pull-back measure ${\sigma}o({\varphi}^{\ast})^{-1}$. In this paper, we prove that the composition operator $C_{\varphi}$ is metrically bounded on $N^P$(B) if and only if ${\mu}(S(\zeta,\delta)){\le}C{\delta}^n$ for some constant C and $C_{\varphi}$ is metrically compact on $N^P(B)$ if and only if ${\mu}(S(\zeta,\delta))=o({\delta}^n)$ as ${\delta}\;{\downarrow}\;0$ uniformly in ${\zeta}\;\in\;S. Our results are an analogous results for Mac Cluer's Carleson-measure criterion for the boundedness or compactness of $C_{\varphi}$ on the Hardy spaces $H^P(B)$.

SiGe pMOSFET의 채널구조와 바이어스 조건에 따른 잡음 특성 (Low-Frequency Noise Characteristics of SiGe pMOSFET Depending upon Channel Structures and Bias Conditions)

  • 최상식;양현덕;김상훈;송영주;조경익;김정훈;송종인;심규환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.5-6
    • /
    • 2005
  • High performance SiGe heterostructure metal-oxide-semiconductor field effect transistors(MOSFETs) were fabricated using well-controlled delta-doping of boron and SiGe/Si heterostructure epitaxal layers grown by reduced pressure chemical vapor deposition. In this paper, we report 1/f noise characteristics of the SiGe MOSFETs measured under various bias conditions of the gate and drain voltages changing in linear operation regions. From the noise spectral density, we found that the gate and drain voltage dependence of the noise represented same features, as usually scaled with $f^1$. However, 1/f noise was found to be much lower in the device with boron delta-doped layer, by a factor of $10^{-1}\sim10^{-2}$ in comparion with the device fabricated without delta-doped layer. 1/f noise property of delta-doped device looks important because the device may replace bipolar transistors most commonly embedded in high-frequency oscillator circuits.

  • PDF

Development and Validation of Generalized Linear Regression Models to Predict Vessel Enhancement on Coronary CT Angiography

  • Masuda, Takanori;Nakaura, Takeshi;Funama, Yoshinori;Sato, Tomoyasu;Higaki, Toru;Kiguchi, Masao;Matsumoto, Yoriaki;Yamashita, Yukari;Imada, Naoyuki;Awai, Kazuo
    • Korean Journal of Radiology
    • /
    • 제19권6호
    • /
    • pp.1021-1030
    • /
    • 2018
  • Objective: We evaluated the effect of various patient characteristics and time-density curve (TDC)-factors on the test bolus-affected vessel enhancement on coronary computed tomography angiography (CCTA). We also assessed the value of generalized linear regression models (GLMs) for predicting enhancement on CCTA. Materials and Methods: We performed univariate and multivariate regression analysis to evaluate the effect of patient characteristics and to compare contrast enhancement per gram of iodine on test bolus (${\Delta}HUTEST$) and CCTA (${\Delta}HUCCTA$). We developed GLMs to predict ${\Delta}HUCCTA$. GLMs including independent variables were validated with 6-fold cross-validation using the correlation coefficient and Bland-Altman analysis. Results: In multivariate analysis, only total body weight (TBW) and ${\Delta}HUTEST$ maintained their independent predictive value (p < 0.001). In validation analysis, the highest correlation coefficient between ${\Delta}HUCCTA$ and the prediction values was seen in the GLM (r = 0.75), followed by TDC (r = 0.69) and TBW (r = 0.62). The lowest Bland-Altman limit of agreement was observed with GLM-3 (mean difference, $-0.0{\pm}5.1$ Hounsfield units/grams of iodine [HU/gI]; 95% confidence interval [CI], -10.1, 10.1), followed by ${\Delta}HUCCTA$ ($-0.0{\pm}5.9HU/gI$; 95% CI, -11.9, 11.9) and TBW ($1.1{\pm}6.2HU/gI$; 95% CI, -11.2, 13.4). Conclusion: We demonstrated that the patient's TBW and ${\Delta}HUTEST$ significantly affected contrast enhancement on CCTA images and that the combined use of clinical information and test bolus results is useful for predicting aortic enhancement.

6 시그마와 총 오차 허용범위의 개발에 대한 연구 (A Study of Six Sigma and Total Error Allowable in Chematology Laboratory)

  • 장상우;김남용;최호성;김영환;추경복;정혜진;박병옥
    • 대한임상검사과학회지
    • /
    • 제37권2호
    • /
    • pp.65-70
    • /
    • 2005
  • Those specifications of the CLIA analytical tolerance limits are consistent with the performance goals in Six Sigma Quality Management. Six sigma analysis determines performance quality from bias and precision statistics. It also shows if the method meets the criteria for the six sigma performance. Performance standards calculates allowable total error from several different criteria. Six sigma means six standard deviations from the target value or mean value and about 3.4 failures per million opportunities for failure. Sigma Quality Level is an indicator of process centering and process variation total error allowable. Tolerance specification is replaced by a Total Error specification, which is a common form of a quality specification for a laboratory test. The CLIA criteria for acceptable performance in proficiency testing events are given in the form of an allowable total error, TEa. Thus there is a published list of TEa specifications for regulated analytes. In terms of TEa, Six Sigma Quality Management sets a precision goal of TEa/6 and an accuracy goal of 1.5 (TEa/6). This concept is based on the proficiency testing specification of target value +/-3s, TEa from reference intervals, biological variation, and peer group median mean surveys. We have found rules to calculate as a fraction of a reference interval and peer group median mean surveys. We studied to develop total error allowable from peer group survey results and CLIA 88 rules in US on 19 items TP, ALB, T.B, ALP, AST, ALT, CL, LD, K, Na, CRE, BUN, T.C, GLU, GGT, CA, phosphorus, UA, TG tests in chematology were follows. Sigma level versus TEa from peer group median mean CV of each item by group mean were assessed by process performance, fitting within six sigma tolerance limits were TP ($6.1{\delta}$/9.3%), ALB ($6.9{\delta}$/11.3%), T.B ($3.4{\delta}$/25.6%), ALP ($6.8{\delta}$/31.5%), AST ($4.5{\delta}$/16.8%), ALT ($1.6{\delta}$/19.3%), CL ($4.6{\delta}$/8.4%), LD ($11.5{\delta}$/20.07%), K ($2.5{\delta}$/0.39mmol/L), Na ($3.6{\delta}$/6.87mmol/L), CRE ($9.9{\delta}$/21.8%), BUN ($4.3{\delta}$/13.3%), UA ($5.9{\delta}$/11.5%), T.C ($2.2{\delta}$/10.7%), GLU ($4.8{\delta}$/10.2%), GGT ($7.5{\delta}$/27.3%), CA ($5.5{\delta}$/0.87mmol/L), IP ($8.5{\delta}$/13.17%), TG ($9.6{\delta}$/17.7%). Peer group survey median CV in Korean External Assessment greater than CLIA criteria were CL (8.45%/5%), BUN (13.3%/9%), CRE (21.8%/15%), T.B (25.6%/20%), and Na (6.87mmol/L/4mmol/L). Peer group survey median CV less than it were as TP (9.3%/10%), AST (16.8%/20%), ALT (19.3%/20%), K (0.39mmol/L/0.5mmol/L), UA (11.5%/17%), Ca (0.87mg/dL1mg/L), TG (17.7%/25%). TEa in 17 items were same one in 14 items with 82.35%. We found out the truth on increasing sigma level due to increased total error allowable, and were sure that the goal of setting total error allowable would affect the evaluation of sigma metrics in the process, if sustaining the same process.

  • PDF

Efficiency and Midgut Histopathological Effect of the Newly Isolated Bacillus thuringiensis KS ${\delta}$-Endotoxins on the Emergent Pest Tuta absoluta

  • Jamoussi, Kais;Sellami, Sameh;Nasfi, Zina;Krichen-Makni, Saloua;Tounsi, Slim
    • Journal of Microbiology and Biotechnology
    • /
    • 제23권8호
    • /
    • pp.1099-1106
    • /
    • 2013
  • Tuta absoluta (Povolny, 1994) is a devastating moth to the Solanaceae plants. It is a challenging pest to control, especially on tomatoes. In this work, we studied the entomopathogenic activity of the Cry-forming ${\delta}$-endotoxins produced by Bacillus thuringiensis strain KS and B. thuringiensis kurstaki reference strain HD1 against T. absoluta. These strains carried the cry2, cry1Ab, cry1Aa/cry1Ac, and cry1I genes, and KS also carried a cry1C gene. The ${\delta}$-endotoxins of KS were approximately twofold more toxic against the third instar larvae than those of HD1, as they showed lower 50% and 90% lethal concentrations (0.80 and 2.70 ${\mu}g/cm^2$ (${\delta}$-endotoxins/tomato leaf)) compared with those of HD1 (1.70 and 4.50 ${\mu}g/cm^2$) (p < 0.05). Additionally, the larvae protease extract showed at least six caseinolytic activities, which activated the KS and HD1 ${\delta}$-endotoxins, yielding the active toxins of about 65 kDa and the protease-resistant core of about 58 kDa. Moreover, the histopathological effects of KS and HD1 ${\delta}$-endotoxins on the larvae midgut consisted of an apical columnar cell vacuolization, microvillus damage, and epithelial cell disruption. These results showed that the KS strain could be a candidate for T. absoluta control.

$Bi_2O_3$ 첨가에 의한 Ca[($Li_{1/3}Nb_{2/3}$)$_{1-x}$$Ti_{x}$$O_{3-{\delta}}$ 세라믹스의 마이크로파 유전 특성 (Microwave Dielectric Properties of Ca[($Li_{1/3}Nb_{2/3}$)$_{1-x}$$Ti_{x}$]$O_{3-{\delta}}$ with $Bi_2O_3$ Additives)

  • 하종윤;최지원;이동윤;윤석진;최두진;김현재
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.131-134
    • /
    • 2002
  • The effect of the addition on the densification, low temperature sintering, and microwave dielectric properties of the Ca[($Li_{1/3}Nb_{2/3}$)$_{1-x}$$Ti_{x}$]$O_{3-{\delta}}$/(CLNT) was investigated. $Bi_2O_3$ additives improved the dencification and reduced the sintering temperature from $1150^{\circ}C$ to $900^{\circ}C$ of CLNT microwave dielectric ceramics. As increasing $Bi_2O_3$ contents, the dielectric constants and bulk density were increased. The quality factor, however, was decreased slighty. The temperature coefficients of the resonant frequency shifted positive value as increasing $Bi_2O_3$ contents. The dielectric properties of Ca[($Li_{1/3}Nb_{2/3}$)$_{1-x}$$Ti_{x}$]$O_{3-{\delta}}$ and Ca[($Li_{1/3}Nb_{2/3}$)$_{0.8}Ti_{0.2}$]$O_{3-{\delta}}$ with 5wt% $Bi_2O_3$ sintered at $900^{\circ}C$ for 3h were $\varepsilon_{r}$=20, 35 Q.$f_{0}$=6500, 11,000 GHz, $\tau_{f}$=4, 13 ppm/$^{\circ}C$, respectively.

  • PDF