• Title/Summary/Keyword: Delay measurement

Search Result 641, Processing Time 0.029 seconds

A Jitter Suppressed DLL-Based Clock Generator (지연 고정 루프 기반의 지터 억제 클록 발생기)

  • Choi, Young-Shig;Ko, Gi-Yeong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.7
    • /
    • pp.1261-1266
    • /
    • 2017
  • A random and systematic jitter suppressed delay locked loop (DLL)-based clock generator with a delay-time voltage variance converter (DVVC) and an averaging circuit (AC) is presented. The DVVC senses the delay variance of each delay stage and generates a voltage. The AC averages the output voltages of two consecutive DVVCs to suppress the systematic and random delay variance of each delay stage in the VCDL. The DVVC and AC averages the delay time of successive delay stages and equalizes the delay time of all delay stages. In addition, a capacitor with a switch working effectively as a negative feedback function is introduced to reduce the variation of the loop filter output voltage. Measurement results of the DLL-based clock generator fabricated in a one-poly six-metal $0.18{\mu}m$ CMOS process shows 13.4-ps rms jitter.

Performance Analysis of Low-Order Surface Methods for Compact Network RTK: Case Study

  • Song, Junesol;Park, Byungwoon;Kee, Changdon
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.4 no.1
    • /
    • pp.33-41
    • /
    • 2015
  • Compact Network Real-Time Kinematic (RTK) is a method that combines compact RTK and network RTK, and it can effectively reduce the time and spatial de-correlation errors. A network RTK user receives multiple correction information generated from reference stations that constitute a network, calculates correction information that is appropriate for one's own position through a proper combination method, and uses the information for the estimation of the position. This combination method is classified depending on the method for modeling the GPS error elements included in correction information, and the user position accuracy is affected by the accuracy of this modeling. Among the GPS error elements included in correction information, tropospheric delay is generally eliminated using a tropospheric model, and a combination method is then applied. In the case of a tropospheric model, the estimation accuracy varies depending on the meteorological condition, and thus eliminating the tropospheric delay of correction information using a tropospheric model is limited to a certain extent. In this study, correction information modeling accuracy performances were compared focusing on the Low-Order Surface Model (LSM), which models the GPS error elements included in correction information using a low-order surface, and a modified LSM method that considers tropospheric delay characteristics depending on altitude. Both of the two methods model GPS error elements in relation to altitude, but the second method reflects the characteristics of actual tropospheric delay depending on altitude. In this study, the final residual errors of user measurements were compared and analyzed using the correction information generated by the various methods mentioned above. For the performance comparison and analysis, various GPS actual measurement data were collected. The results indicated that the modified LSM method that considers actual tropospheric characteristics showed improved performance in terms of user measurement residual error and position domain residual error.

A time delay measurement of a chirped fiber grating by using bidirectional modulation of an optical intensity modulator (광변조기의 양방향 변조를 이용한 chirped fiber grating의 시간지연 측정법)

  • Jeon, Geum-Soo;Lee, Yong-Gu;Ban, Jae-Kyung;Heo, Hyun
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.6
    • /
    • pp.510-514
    • /
    • 2002
  • A simple method for a time delay measurement of a chirped fiber grating by using bidirectional modulation of a Mach-Zehnder modulator has been proposed. The bidirectionally modulated light with time difference makes an interference fringe in the RF domain. The time delay of a chirped fiber grating can be obtained by measuring the period of the RF interference fringe for different wavelengths. We have measured the time delay of a chirped fiber grating with a chirped length of 5 cm and a bandwidth of 3.16 nm. The average slope of the time delay has been measured to be 183 ps/nm and its uncertainty has been less than $\pm$1.7%.

Integrated Navigation System Design of Electro-Optical Tracking System with Time-delay and Scale Factor Error Compensation

  • Son, Jae Hoon;Choi, Woojin;Oh, Sang Heon;Hwang, Dong-Hwan
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.11 no.2
    • /
    • pp.71-81
    • /
    • 2022
  • In order for electro-optical tracking system (EOTS) to have accurate target coordinate, accurate navigation results are required. If an integrated navigation system is configured using an inertial measurement unit (IMU) of EOTS and the vehicle's navigation results, navigation results with high rate can be obtained. Due to the time-delay of the navigation results of the vehicle in the EOTS and scale factor errors of the EOTS IMU in high-speed and high dynamic operation of the vehicle, it is much more difficult to have accurate navigation results. In this paper, an integrated navigation system of EOTS which compensates time-delay and scale factor error is proposed. The proposed integrated navigation system consists of vehicle's navigation system which provides time-delayed navigation results, an EOTS IMU, an inertial navigation system (INS), an augmented Kalman filter and integration Kalman filter. The augmented Kalman filter outputs navigation results, in which the time-delay of the vehicle's navigation results is compensated. The integration Kalman filter estimates position, velocity, attitude error of the EOTS INS and accelerometer bias, accelerometer scale factor error, gyro bias and gyro scale factor error from the difference between the output of the augmented Kalman filter and the navigation result of the EOTS INS. In order to check performance of the proposed integrated navigation system, simulations for output data of a measurement generator and land vehicle experiments were performed. The performance evaluation results show that the proposed integrated navigation system provides more accurate navigation results.

Identification of continuous time-delay systems using the genetic algorithm

  • Hachino, Tomohiro;Yang, Zi-Jiang;Tsuji, Teruo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10b
    • /
    • pp.1-6
    • /
    • 1993
  • This report proposes a novel method of identification of continuous time-delay systems from sampled input-output data. By the aid of a digital pre-filter, an approximated discrete-time estimation model is first derived, in which the system parameters remain in their original form and the time delay need not be an integral multiple of th sampling period. Then an identification method combining the common linear least squares(LS) method or the instrumental variable(IV) method with the genetic algorithm(GA) is proposed. That is, the time-delay is selected by the GA, and the system parameters are estimated by the LS or IV method. Furthermore, the proposed method is extended to the case of multi-input multi-output systems where the time-delays in the individual input channels may differ each other. Simulation resutls show that our method yields consistent estimates even in the presence of high measurement noises.

  • PDF

Wavelet Compression Method with Minimum Delay for Mobile Tele-cardiology Applications (이동형 Tele-cardiology 시스템 적용을 위한 최저 지연을 가진 웨이브릿 압축 기법)

  • Kim Byoung-Soo;Yoo Sun-Kook;Lee Moon-Hyoung
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.11
    • /
    • pp.786-792
    • /
    • 2004
  • A wavelet based ECG data compression has become an attractive and efficient method in many mobile tele-cardiology applications. But large data size required for high compression performance leads a serious delay. In this paper, new wavelet compression method with minimum delay is proposed. It is based on deciding the type and compression ratio(CR) of block organically according to the standard deviation of input ECG data with minimum block size. Compression performances of the proposed algorithm for different MIT ECG Records were analyzed comparing other ECG compression algorithm. In addition to the processing delay measurement, compression efficiency and reconstruction sensitivity to error were also evaluated via random noise simulation models. The results show that the proposed algorithm has both lower PRD than other algorithm on same CR and minimum time in the data acquisition, processing and transmission.

A Study on In-Process Performance Diagnosis of Hydraulic Servovalves - First Report : Position Control System - (유압서보밸브의 인-프로세스 성능 진단에 관한 연구 I - 유압실린더 위치제어계의 경우 -)

  • Kim S.D.;Kim K.H.;Song J.S.;Ham Y.B.;Lee J.C.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.1
    • /
    • pp.7-14
    • /
    • 2006
  • In this paper, an in-process diagnosis method for performance of position control servo system was studied, which was based upon null bias, slew-rate ratio and delay time measurement. Slew-rate ratio and delay time were analyzed by theoretical analysis, computer simulation and experiment. As a result of these analysis, when spool of servovalve was weared, slew-rate ratio was decreased and delay time was increased.

  • PDF

A Low-Jitter DLL-Based Clock Generator with Two Negative Feedback Loops

  • Choi, Young-Shig;Park, Jong-Yoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.4
    • /
    • pp.457-462
    • /
    • 2014
  • This letter proposes a low-jitter DLL-based clock generator with two negative feedback loops. The main negative feedback loops suppress the jitter of DLL. The additional negative feedback loops suppress the delay-time variance of each delay stages. Both two negative feedback loops in a DLL results in suppressing the jitter of clock signal further. Measurement results of the DLL-based clock generator with two negative feedback loops fabricated in a one-poly six-metal $0.18{\mu}m$ CMOS process show 5.127-ps rms jitter and 47.6-ps peak-to-peak jitter at 1 GHz.

Development of Signal Monitoring Platform for Sound Source Localization System

  • Myagmar, Enkhzaya;Kwon, Soon Ryang;Lee, Dong Myung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.04a
    • /
    • pp.961-963
    • /
    • 2012
  • The sound source localization system is used to some area such as robotic system, object localization system, guarding system and medicine. So time delay estimation and angle estimation of sound direction are studied until now. These days time delay estimation is described in LabVIEW which is used to create innovative computer-based product and deploy measurement and control systems. In this paper, the development of signal monitoring platform is presented for sound source localization. This platform is designed in virtual instrument program and implemented in two stages. In first stage, data acquisition system is proposed and designed to analyze time delay estimation using cross correlation. In second stage, data obtaining system which is applied and designed to monitor analog signal processing is proposed.

Adaptive Control of Multiplexed Closed Circuit Anesthesia

  • Jee, Gyu-In;Roy, Rob
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.79-81
    • /
    • 1992
  • This paper describes the design of an adaptive closed circuit anesthesia controller based on a multiplexed mass spectrometer system. The controller deals with measurement deterioration caused by measurement delay and rise time through a tong catheter as well as long sampling times due to the multiplexed measurements. Measurement data is extrapolated between sampling periods to increase the estimation convergence rate. A multiple-step-ahead predictive control algorithm is used to calculate intermediatc control inputs between sampling intervals. Simulations are used to validate the designed controller.

  • PDF