• Title/Summary/Keyword: Defected elements

Search Result 18, Processing Time 0.02 seconds

Influence to the Doppler Images by the Defects of SAE in the Probe of Medical Ultrasonic Scanners (초음파 프로브에서 인접 단위 소자군(SAE) 결함이 도플러 영상에 미치는 영향)

  • Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.7-15
    • /
    • 2015
  • A ultrasonic probe is very important in medical ultrasonic image, but the frequency of probe defects are often. Therefore practical tools for probe based ultrasonic QA should be developed. Advanced research on the effects of the probe defects on the quality of ultrasonic images is required. This study has investigated the effects of the defects in the probe elements influence Doppler images in the medical ultrasonic scanners. Especially the defects in a set of adjacent elements(SAE) electrically disconnected influence Doppler images were tested. The results show Doppler brightness and velocity became rapidly reduced as the defected elements is located centrally, as the defected elements is activated. The more the defected elements increased, the more Doppler brightness and velocity increased. As a set of the element disconnected moved, it appeared Doppler velocity starting to decrease and then was followed by brightness. The strength is not consistent with the velocity in the number and location of the defected elements. The defects in the probe elements influence Doppler velocity when the defected elements got out of the elements activated at Doppler mode.

A Study for the Equivalent Circuit and Slow-Wave Factor of Defected Ground Structure Transmission Line (DGS 전송선로의 등가회로와 전파지연계수에 대한 재고찰)

  • Lim, Jong-Sik;Koo, Ja-Kyung;Han, Sang-Min;Jeong, Yong-Chae;Ahn, Dal
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.2041-2046
    • /
    • 2008
  • A frequency-dependent slow-wave factor (SWF) and equivalent circuit model of transmission line with defected ground structures (DGS) is described. Once S-parameters of a DGS transmission line are given, the conventional frequency -independent equivalent circuit elements are extracted using 3dB cutoff and resonant frequencies (Fc and Fo) as the first step. Using the initial equivalent elements and simple transmission line theories, a frequency-dependent equivalent transmission line model is established through an analytical method, and finally the frequency dependent SWF is calculated. The proposed equivalent circuit model and SWF are frequency-dependent and more reliable because even small insertion loss within available passband is considered, while they have been independent of frequency.

A design of a lowpass filter using Quad-Spiral Defected Ground Structure (Quad-Spiral Defected Ground Structure를 이용한 저역통과 여파기 설계)

  • Jeong, Yong-Woo;Kim, Chul-Soo;Park, Kyu-Ho;Ahn, Dal
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.343-346
    • /
    • 2003
  • A new structure to design low pass filters (LPFs) is presented rho proposed structure has the etched shape of Quad-Spiral DGS(Defected Ground Structure) on microstrip transmission lines. By extracting the equivalent circuit elements of unit Quad-Spiral DGS, LPFs are designed easily. The equivalent circuit of Quad-Spiral DGS consists of a step impedance resonator and lumped elements. The proposed LPF provided steep rejection characteristics with 5-poles. Experimental results show excellent agreements with circuit simulation results in wide band and the validity of our circuit modeling for LPF design. The result shows another possibility of Quad Spiral DGS for microwave devices.

  • PDF

The Impacts of Piezoelectric Elements' Defects On Color & Power Doppler Images (초음파 프로브에서 소자결함이 컬러 및 파워 도플러 영상에 미치는 영향)

  • Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.443-449
    • /
    • 2015
  • An ultrasound probe has a big impact on Doppler images even though it has very high risk of frequent function-breakdowns occurring in medical ultrasound scanners. This study experimentally analyses the impacts of an ultrasonic probe's defected elements on power & color Doppler images. The results show that, the bigger the size of defected probe elements is, and the closer a group of action elements is to the center, the more the brightness of images and the velocity of Doppler diminish. When elements' defects increase in color & power Doppler images, false images are formed to be mistaken for blood-vessel plaque in neighboring regions. Accordingly, whenever element defects are suspected, we need check-up process in B-mode. From this respective, it is advisable to have primary interest in a probe and carry out continuous probe QA for ultrasonography.

Influence to the Doppler Images by the Defects of Piezoelectric Elements of the Probe of Medical Ultrasonic Scanners (Focusing on the Impact of an Increase in the Defects of Piezoelectric Elements) (초음파 프로브 소자 결함이 도플러 영상에 미치는 영향 (소자 결함 증가에 따른 영향을 중심으로))

  • Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.117-124
    • /
    • 2014
  • This study has investigated the effects of the defects in the probe elements influence Doppler images in the medical ultrasonic scanners. This work was implemented that the quality of Doppler images depended on the extent and location of the probe element defected. The probe performance was rated in terms of the number of piezoelectric elements lost and this was studied in the experiment by electrical disconnection to the elements. The results showed that Doppler velocity became rapidly reduced as the defected elements encountered with the element group activated at the Doppler mode, not as the flow velocity. The effect of the probe defect is decreased when the defects occurred at the element group activated for Doppler mode, as was increased the number of the elements. It was observed that the higher the flow velocity of Doppler flow phantom is, the wider the spectrum of Doppler is. And the Doppler velocity soared up and the dispersion of image brightness is increased when the defected elements got out of the elements activated at Doppler mode. The result showed that TADVP(time-average-Doppler-velocity-profile) is decreased with the increase of the probe element defect, especilly in the region of high frequency. It is expected that the research of various defects of probe elements are needed, and this study can be practical tools for probe based ultrasonic QA in the future.

A Study on the Characteristics of Microwave Transmission Lines Having Defected Ground Structures and Lumped Elements (결함접지구조와 집중소자를 지닌 초고주파 전송선로의 전기적 특성 연구)

  • Lim Jong-Sik;Bae Ju-Seok;Choi Kwan-Sun;Ahn Dal
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.4
    • /
    • pp.616-624
    • /
    • 2006
  • In this paper, the transfer characteristics of high frequency transmission line having defected ground structure (DGS) and lumped elements are described. When a DGS, which is a kind of periodic structure, is inserted into a transmission line, its equivalent inductance and capacitance elements are added to the characteristics of the standard transmission line. This generates resonance, 3dB cut-off frequency, low-pass, band rejection, and band pass characteristics, and causes a slow-wave and enlarged electrical length of the transmission line. In addition, if the DGS is combined by a lumped element such as resistor, capacitor, and inductor, the resonant and cut-off frequencies moves up or down and other changes occur in the transmission characteristics. The variation of the transmission characteristics is described with the qualitative prediction and measured data.

  • PDF

A Parasitic Elements Extraction of the Distributed Elements and an Application of the BPF Using the Short-Open Calibration Method (단락 개방 Calibration 방법을 이용한 분포 정수 소자의 기생 소자 추출 및 대역 통과 필터에의 응용)

  • Kim, Yu-Seon;Nam, Hun;Lim, Yeong-Seog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.2
    • /
    • pp.115-123
    • /
    • 2009
  • In this paper, we extract the parasitic elements of the transmission line with the defected ground structure(DGS) and the short-circuited comb line section using the Short-Open Calibration(SOC). The scattering matrixes of short, open and the distributed elements in microstrip line are measured by full electro-magnetic(EM) simulator and Vector Network Analyser(VNA). The electro-magnetic effects of the proposed structures are considered by the II and T equivalent circuits with frequency independent elements, and the relations between the measured scattering parameters and the elements in the circuits are shown by performing 2 port network analysis. Moreover, to design the 2.4 GHz bandpass filter with second order butterworth prototype, the proposed methods are applied. As results, the measured $S_{11}$ and $S_{21}$ indicate -20 dB and -1.3 dB at center frequency, and these are shown within 5 % error compare to the predicted results at $0.5{\sim}5\;GHz$.

A New Type of 5-Pole Low Pass Filter Using Defected Ground Structure (결함 접지 구조를 이용한 새로운 5-단 저역 통과 여파기)

  • Lim Jong-Sik;Kim Chul-Soo;Ahn Dal;Jeong Yong-Chae;Nam Sangwook;Kim Kwangsoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.6 s.97
    • /
    • pp.594-602
    • /
    • 2005
  • In this paper, a new type of 5-pole low pass filter(LPF) having defected ground structure(DGS) and very wide transmission line elements is proposed. The previously presented design method of 3-stage LPF using DGS is generalized to design N-pole LPFs for $N\geq5$. As an example, a 5-pole LPF having DGS is designed and measured. The accurate curve-fitting method to determine the series inductors in the prototype filter, and ultimately the size of DGS is described. The proposed 5-pole LPF has transmission line elements with a very low impedance to realize the required shunt capacitance instead of open stubs. Therefore, open stub. Therefore, open stub, Tee-junction, Cross-junction, and high impedance line are not required for the proposed LPF, while they all have been essential in conventional LPFs.

A Study on the Characteristic of Variable Impedance Line using DGS (DGS를 이용한 가변 임피던스 선로 특성에 관한 연구)

  • Kim Young-Ju;Joung Myoung-Sub;Park Jun-Seok;Cho Hong-Goo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.1
    • /
    • pp.35-40
    • /
    • 2005
  • In this paper, we designed and fabricated the variable impedance line by using the DGS(Defected Ground Structure) which is useful in mounting the external lumped elements. Also we used a varactor diode as Control device stuff at the proposed variable impedance line. We are able to change the impedance of transmission line as varied the capacitance of varactor diode by adjusting DC bias. The impedance variation of the proposed DGS line is about maximum 70 Ω. We will study about the application of DAM(Direct antenna modulation) in the future work.

An Equivalent Circuit Model for a Dumbbell-Shaped DGS Microstrip Line

  • Woo, Duk-Jae;Lee, Taek-Kyung
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.4
    • /
    • pp.415-418
    • /
    • 2014
  • This paper presents an equivalent circuit model for a dumbbell-shaped defected ground structure (DGS) in a microstrip line. The effects of equivalent circuit elements of a dumbbell-shaped DGS and their magnetic coupling to the host transmission line are modeled as a simple lumped-element circuit. In addition, simple approximate expressions to determine the main circuit parameters for this model are presented. The transfer characteristic calculated by the proposed circuit model is compared with the results of EM simulation and measurement.