• 제목/요약/키워드: Daylighting performance

검색결과 125건 처리시간 0.023초

LCC 기법을 통한 자연채광의 경제성 분석에 대한 연구 (A Feasibility Study on the Benefit of Daylighting by LCC Analysis)

  • 김정태;김곤
    • KIEAE Journal
    • /
    • 제6권1호
    • /
    • pp.3-10
    • /
    • 2006
  • As has been expected, economic factors are a major consideration in almost every decision in building design process. Assuming that improving a lighting system, existing or proposed, will reduce operating cost, what preliminary economic guidelines can be established to determine whether any proposed investment appears cost effective? In such a case a reasonable technique to compare system costs is by life-cycle costing. Stated simply, a life-cycle cost represents the total cost of a system over its entire life cycle, that is, the sum of first cost and all future costs. This paper aims to exemplify the benefit of daylighting in term of economic consideration. Four different electric lighting system designs are proposed and a lighting control system that is continuously operating according to the level of daylight in the space has been adapted. The accumulated performance of electric and daylighting is figured out to declare the effective depth of daylight in the space. The analysis on the saving amount of lighting energy due to daylight has been undertaken in answer to the question, that is, several projects are being considered, which is the most desirable from the cost-effectiveness viewpoint. The result shows clearly that although denser layout of lighting fixtures might be more effective to interface to the level of daylight ceaselessly changeable, its economic benefit may not meet the expected criterion the reason of increased initial investment and maintenance cost for the fixtures and control hardware.

생애주기비용분석 기법을 이용한 채광기능성 창호시스템의 경제성 평가에 관한 연구 (Economic Probation on the Benefit of Daylighting by a Light-Guide System)

  • 김곤;김정태
    • KIEAE Journal
    • /
    • 제6권3호
    • /
    • pp.11-18
    • /
    • 2006
  • Attention on daylighting should be focused not so much on a simple maximization of the natural light available in a space, as on improving the quality of lighting by ensuring as even but intense distribution of illumination in inner areas. An architectural means of optimal daylight distribution is by using so-called light shelf systems, horizontal shading and redirecting devices. The overall performance of the daylighting system can be improved by the incorporation with electric lighting control devices. This paper aims to exemplify the benefit of daylighting in term of economic consideration. In such a case a reasonable technique to compare system costs is by life-cycle costing. Stated simply, a life-cycle cost represents the total cost of a system over its entire life cycle, that is, the sum of first cost and all future costs. Four different electric lighting system designs are proposed and a lighting control system that is continuously operating according to the level of daylight in the space has been adapted. The result shows clearly that although denser layout of lighting fixtures might be more effective to interface to the level of daylight ceaselessly changeable, its economic benefit may not meet the expected criterion the reason of increased initial investment and maintenance cost for the fixtures and control devices.

자연채광 성능평가용 인공천공돔(Sky Simulator)의 개발 및 신뢰성 검증 (Development and its Validation of Sky Simulator Facilities for Daylighting Evaluation)

  • 김정태;김곤;유인혜
    • KIEAE Journal
    • /
    • 제5권4호
    • /
    • pp.51-57
    • /
    • 2005
  • For the evaluating daylighting performance, field measurement, scale model test and a set of computer tools can be applied. For the scale model measurements, the sky simulator is a vital facility to represent the desired sky conditions consistently. Recently K university has developed a large size sky simulator, 6m-diameter and 3.7m-height, that is suitable for the international standard. To verify the reliability of the sky simulator, the luminance distribution on the inner sky surface was measured and compared with the CIE standard overcast sky model. It is found that the sky simulator can be reproduced the CIE standard overcast sky condition with 4.3% as mean difference. K university sky simulator is fully validated for usability and accuracy for daylighting researches.

경북북부지역 전통 양반가옥의 채광조절 기능에 관한 연구 -처마, 창호(窓戶), 창호지(窓戶紙)를 중심으로- (Daylighting Controls of Korean Traditional Houses built in Chosun Dynasty especially on examples located in northern Gyeongbuk province)

  • 김곤;구재오
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.79-85
    • /
    • 2004
  • There is something valuable in Korean traditional architecture that does not change even after more than a number of years. Each design element of traditional houses has its own role to embody natural, healthy, and environment-friendly architectural planning. With traditional already-built examples located in the northern area of Gyeongbuk province, this study attempts to untangle some of the daylighting control issues in opening design. By looking at more than just photometric materials, at some threshold level, the whole of daylighting control characteristics of their openings is being surveyed from the viewpoint of geometric relationship between their roof structures and windows. As a glazing material, in addition, Korean traditional window covering paper, Changhoji, is evaluated for its transmittal performance under artificial and real skies as well.

초등학교 교실의 빛 환경 실측에 관한 연구 (A Study on the Experiment of Luminous Environment in Classroom of An Elementary School)

  • 박경은;김준태
    • 교육시설
    • /
    • 제9권5호
    • /
    • pp.13-21
    • /
    • 2002
  • Daylighting in educational environment is very important as it has an effect on students' performance as well as in their visual health. It is regarded as a good energy conservation method in saving energy used for lighting. This study conducted initial daylight measurements to analyze luminous environment in classrooms of Korean elementary school. The results indicated that the typical classroom had a reasonable level of daylight. However, it also found that the classroom had some problems of the uniformity of illuminance and the contrast of brightness of surfaces in the classroom. It is argued that daylighting design for school classroom should consider these aspects to make daylit classrooms ideal so as to provide comfortable visual environment.

실내조명용 화이버 광학 집광기의 성능에 관한 실험적 평가 (Experimental Evaluation of a Fiber Optic Concentrator for Daylighting)

  • 한현주;김정태
    • 한국태양에너지학회 논문집
    • /
    • 제28권3호
    • /
    • pp.27-34
    • /
    • 2008
  • A series of outdoor tests were conducted on a fiber optic solar concentrator system for its performance on daylighting. The system is comprised of four main components - a parabolic dish reflector, a convex mirror, a homogenizer tube and an optical fiber cable. Results show that the system could be successfully applied for indoor lighting if some improvements are made for light transmiting (optical) cables. A maximum concentration ratio of 90 was observed delivering the illuminance of 4,800 lux at a distance of 1.2m from the diffuser for the outdoor illuminance of 102,100 lux.

Atrium Builing의 자연채광특성에 관한 기초적 연구 (A Fundamental Study on the Daylighting Characters of Atrium Building)

  • 김회서;최인창;서정호
    • 태양에너지
    • /
    • 제12권3호
    • /
    • pp.21-27
    • /
    • 1992
  • 본 연구는 아트리움 빌딩에 대한 자연채광의 영향을 모델에 의해서 실험하였다. 이러한 방법에 의하여 아트리움 빌딩에서의 자연채광의 단계를 예측하는 방법은 여러 가지가 있으나, 그러나 지금까지는 선형아트리움 건물에서 실내자연채광의 다양한 영향을 예측하기에는 충분치 못하였다. 본 연구에서는 효율적인 방법의 제시를 위하여 선형아트리움의 자연채광에 대한 환경 평가를 위해 모형을 제작하고, 평가모델에서의 천공상태, 방위, 종횡비, 층의 변화를 주어 전부 80가지의 변화에 대한 모형측정을 하여, 층높이의 변화와 공간비를 사용하여 분석하였다.

  • PDF

도서관 열람공간의 방위 및 루버시스템에 따른 주광성능 평가 (An Evaluation of Daylight Performance in the Reading Room of a Library according to Different Azimuths and Louver Systems)

  • 박주현;김강수
    • 한국태양에너지학회 논문집
    • /
    • 제26권3호
    • /
    • pp.45-51
    • /
    • 2006
  • Recently, various kinds of daylight system are recognized as an important and useful strategy in energy-efficient building designs. However, a large amount of direct sunlight can make many problems. Therefore, it is necessary to control daylighting through louver systems for high quality visual environment. The purpose of this study is to analyze daylighting performance in the reading room of a library according to different azimuths and louver systems. The results evaluated daylight performance based on the RADIANCE lighting software.

축소모형을 이용한 가변 유리투과체의 채광유형별 성능평가 비교 (Comparative Performance Evaluation of Advanced Daylighting Glazing Systems by Scale Model Measurements)

  • 정인영;김정태
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.27-35
    • /
    • 2004
  • The conventional way to acquire sufficient amount of daylight in interiors is to provide large openings with clear glass. The use of clear glass on the whole facade, however, might cause a sort of visual problem because of the harness of direct sun and brighter sky surface than expected. They should be filtered in opticalway or bounced in the architectural. One of the common solutions for the problem might be the use of photometric glasses with various transmittances for the glass walls. This paper deals with performance data related to the impact of various transmittal glazing materials for window systems in terms of daylighting. A series of scale model measurements was carried out with the fundamental configuration of a commonly used all-glass facades. Additionally some experimental performance index was issued for the better expression of the need of natural lighting.

채광 및 차음성능을 고려한 초등학교 교실의 환경계획적 연구 (A Study on the Environmental Design of the classroom in Elementary Schools with Particular Reference to Natural Lighting and Sound Insulation Performance)

  • 손창환;최영준;이경회
    • 교육시설
    • /
    • 제4권2호
    • /
    • pp.13-20
    • /
    • 1997
  • The total evaluation of educational environment is needed with the rapid growth of the number of students. Especially it is very important to evaluate the physical environment of the classroom in elementary schools where the students spend their whole school life. This study aims to evaluate the daylighting and sound insulation performance of the classroom in elementary school, considering factors such as ceiling height and Wi/Wa (Window/Wall) ratio and then to plan the classroom. Analytic results of the daylighting and sound insulation performance show that the optimum Wi/Wa ratio is $35{\sim}45%$. Reduction of the ceiling height from 3.3m has little influence on the distribution of the indoor daylight factor and sound insulation performance

  • PDF