• Title/Summary/Keyword: Daylighting factor

Search Result 46, Processing Time 0.033 seconds

Study on Comparative Analysis of Daylight Evaluation Tools for Building Environment (건물 주광환경 평가도구의 비교분석에 관한 연구)

  • Park, K.E.;Kim, J.T.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.4
    • /
    • pp.26-34
    • /
    • 2002
  • Daylighting in building is very important as it has an effect on work performance as well as on their visual health. It is also regarded as a good energy conservation measure in saving energy used for lighting. There are many daylighting evaluation tools such as empirical equations, tables, nomograms, diagrams, protractors, computer simulation, scale models. This study conducted initial daylight measurements to analyze luminous environment in classrooms of elementary school and comparative analysis on three daylighting evaluation tools, such as daylight factor calculation formula, the graphic method with BRE Protractor and computer simulation with Adeline 3.0. It is found that the computer simulation tool produced the closest result to actual measurements of luminous environment in elementary school classroom, and the other simplified tools made appropriate results so that they can be used in the early stage of daylighting design process.

A Study on the Computer Simulation Estimate of Light Shelf Using Lightscape (Lightscape를 이용한 광선반의 시뮬레이션 평가 연구)

  • Cho, Yil-Sik;Kim, Ki-Se;Yoon, Jong-Ho;Lee, Jin-Sook
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.3
    • /
    • pp.93-102
    • /
    • 2003
  • One of the promising optical daylighting systems is light shelf type daylighting system, Two types of lighting performance analysis methods are 1) Ray-Tracing method and 2) Radiosity method. The purpose of this paper is to compare two methods in terms of advantages and disadvantages by further looking at the detail algorithm. Also. model verification with Lightscape simulations has been conducted. Effectiveness of light penetration factor in terms of daylighting factor has been investigated and quantified. In summer time. the performance of the light shelf was twice better than the case without it.

Development of Passive-Type Daylighting System for Large Space (대공간 적용을 위한 패시브형 자연채광시스템 개발)

  • Sung, Tae-Kyung;Park, Yeon-Min;Kim, Joung-Min;Lee, Chung-Sik;Lee, Euol-Young;Joung, Che-Bong;Kim, Byung-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.5
    • /
    • pp.1-10
    • /
    • 2015
  • Whereas recent domestic buildings and industrial facilities are being constructed as large as possible, the daylighting systems for the large space have rarely been developed. Domestic situation has been reported as only several small or medium sized daylighting systems have been developed, and the large scaled systems have entirely being imported from abroad. We have developed a large scaled daylighting system for the big space. The developed system have been evaluated in terms of the average system efficiency and daylighting factor. Each results are shown with tabulated experimental data.

Comparative Daylighting Performance of an Interior with Lightshelves and Conventional Glazing; A Mock-Up Experiment (Mock-up을 이용한 일반창호 및 경사형 광선반 창호의 채광성능에 관한 비교 실험)

  • Kim, Jeong Tai;Shin, Hwa Young
    • KIEAE Journal
    • /
    • v.6 no.2
    • /
    • pp.67-74
    • /
    • 2006
  • As sustainable design technologies, advanced daylighting systems with lightshelves have been developed and are currently under monitoring the daylighting performance. This study aims to evaluate the comparative daylighting performance of sloped lightshelf and conventional glazing window with mock-up model, reconstructed as a prototype of Korean office building, sized $12.0m{\times}7.3m{\times}3.7m$ ($w{\times}d{\times}h$) and $1.8m{\times}4.8m$($w{\times}h$) for the south facing side-window was installed on the rooftop of engineering building, Kyung Hee University in Korea. It has an identical configuration of reference room and the test room. For the test room, the sloped type lightshelf system was designed as 10mm transparency sheet glass, tilt angle degree $29^{\circ}$, and total sized 1.28m (interior length 0.88m, exterior length 0.49m). It consisted of daylighting collector, entrance glazing and reflector. To assess daylighting performance, the totally 37 measuring points for illuminance and 2 view points of luminance were monitored in every 30 minutes from 12:00 to 15:00. For the detailed analysis, photometric sensors of each room were installed at work-plane (8 points), wall (7 points), ceiling (3points), and exterior horizontal illuminance (1 point). Luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio, uniformity, and luminance are discussed.

Daylighting Performance of Lightpipe under Different Sky Conditions (천공상태에 따른 수직형 광파이프 시스템의 채광성능 평가)

  • Kong, Hyo Joo;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.3
    • /
    • pp.101-106
    • /
    • 2008
  • The use of daylighting has been increased recently due to energy and visual comfort. The aims of interior daylighting are to adequately illuminate visual tasks, to create an attractive visual environment, and to save electrical energy. Lightpipe can improve the distribution of light to interior spaces. This study aims to evaluate the comparative daylighting performance of lightpipe under different sky conditions with mock-up model, sized $6m{\times}6m{\times}4m$ ($w{\times}d{\times}h$). For the purpose, perpendicular lightpipe system was designed as 650 diameter, with an aspect ratio of 2. Totally 49 measuring points of and two of outdoor illuminance on the horizontal plane were monitored from 09:00 to 18:30 on April 29 and May 15 2008. Agilent data logger and photometric sensor were used. Light factor were used to analyse daylight performance under different sky condition. Under overcast sky condition and clear sky condition, the lightpipe system is suitable for KS recommendation level of illuminance.

Evaluation of the daylight performance of adjacent interior spaces in four-sided atrium according to the height ratio of atrium, and the transmittance of atrium canopy (4면형 아트리움의 높이비와 천창 투과율에 따른 인접 실내공간의 자연채광성능 평가)

  • Yu, Ha-Nui;Lee, Ju-Yun;Song, Kyoo-Dong
    • KIEAE Journal
    • /
    • v.10 no.5
    • /
    • pp.57-62
    • /
    • 2010
  • Studies on daylighting of buildings have been continuously increased due to the recent escalating oil price and low-carbon strategies in developed countries. Daylighting of buildings not only saves electric energy, but provide the occupants with a comfort visual environment. Atrium spaces are adopted by many modern buildings to improve daylight performance of deep interior spaces. Among the various types of atria, the four-sided type atrium is frequently adopted by library buildings, governmental buildings and office buildings. This study aims to suggest daylighting design data for adjacent occupied spaces by conducting dynamic simulations using Daysim program. Daylight Factor(DF), Daylight Autonomy(DA) and Useful Daylight Illuminance(UDI) levels for 12 measurement points in adjacent occupied spaces were calculated for square-shape four-sided atria with different SAR(Section Aspect Ratio) and different canopy transmittance.

A study on lighting Diffusion system of Daylight Duct System (광덕트방식 자연채광 시스템의 산광부에 대한 연구)

  • Song, Kyu-Ryol;Park, Gyeong-Woo;Ryu, Han-Ki
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05b
    • /
    • pp.99-104
    • /
    • 2011
  • Daylighting system is an alternative to the energy crisis and environment change. And it is possible improvement system of Architectural Space Environment. Accordingly, it is very useful system. Because Daylight Duct System of Daylighting System gives high performance for its price, distribution rate is very high. But Daylighting Duct System is hard to accurate control. Accordingly, it is difficult to maintain continuously Daylight Environment in Interior Spaces. Lighting Diffusion System has been developed that it is Applying the principle of Reflector and prism diffuser for maximize the efficiency of lighting of Daylight Duct Systems through this study. And then compare lighting performance of Existing System and new Lighting Diffusion System through producing a mock-up. Thus, this study was carried out for the purpose of verification for excellence. It is that installed Each Daylighting Duct System for performance evaluation in a laboratory of width 4m, length 10m, height 2.5m. And illuminance was measured at noon on winter solstice(December 22) under clean sky. The actual measurement result was in the following. Newly developed lighting Diffusion system was measured maximum illuminance 399, minimum illuminance 221, average illuminance 141. Synthetically, daylight factor, uniformity factor and illuminance distribution were improved more than existing system. As a result, it was confirmed that was improved lighting Environment in Interior Spaces.

  • PDF

Comparative Daylighting Performance Analysis of Offices in 1/10, 1/5 Scale Models and Mock-up Model (실물대모형 및 1/5, 1/10축소모형의 자연채광 성능평가에 관한 비교분석)

  • Baik, Seung Heon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.6 no.4
    • /
    • pp.25-32
    • /
    • 2006
  • Mock-up model can be applied to measure accurate performance data but difficult to apply the variables in experiment. There can be a slight experiment errors in Scale model, but various parameters can be applied for a objective experiment. This paper aims to compare the daylighting performance in 1, 1/5, 1/10 scale model of offices and analyze the experiment errors to certificate the influence of model experiment. To analyse daylighting performance, a comparison of a Mock-up model, sized $12.0m(w){\times}7.2m(l){\times}3.7m(h)$, designed for experimentation of daylighting systems and its 1:5, 1:10 scale model. It has an identical configuration of reference room and the test room. For the test room, the lightshelf system was designed as Micro-4 reflective material. To assess work plane illuminance and light factor, photometric sensors of each room were installed at work-plane(6 points) and exterior horizontal illuminance (1 point). And luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio and luminance are discussed.

Daylighting Performance of Topside Lighting Systems for Different Orientations (방위에 따른 정측창 시스템의 채광성능 평가)

  • Kong, Hyo-Joo;Lee, Jin-Seoung;Ahn, Hyun-Tae;Kim, Jeong-Tai
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.1
    • /
    • pp.11-17
    • /
    • 2009
  • Daylighting is core of sustainable design in most buildings. Well-designed daylighting systems can significantly reduce or even eliminate the electric lighting loads during the day time, including air conditioning energy loads. Among window systems. the topside lights systems including monitor lighting, sawtooth lighting, sunscoop and, lightscoop is one of the most popular apparatus to improve the lighting quantity. Also they are important both in terms of energy savings and visual quality. The objective of this study is to analyse daylighting performance of topside lighting system for different orientations. Four types of topside lighting system were tested and comparpd: monitor lighting, sawtooth lighting, lightscoop and sunscoop. Totally 25 measuring points of illuminance on the horizontal plane were monitored from 09:00 to 17:00 on October 6, 2008. Agilent data logger and photometric sensors Li-cor were used. Comparisons with a light factor is discussed. The results found in this study would mean that there were no significant differences in light factor between three cases.

Assessment of The Luminance Distribution from Daylighting window by Using Image Processing Methodology (이미지 프로세싱 기법을 활용한 채광창의 휘도분포 평가)

  • Park, Jong Myung;Lim, Hong Soo;Kim, Jeong Tai;Kim, Gon
    • KIEAE Journal
    • /
    • v.12 no.5
    • /
    • pp.77-84
    • /
    • 2012
  • Daylighting is the controlled admission of natural light into a space, reducing electric lighting and saving energy. By providing a direct link to the dynamic and perpetually evolving patterns of outdoor illumination, daylighting helps create a visually stimulating and comfort environment for building occupants, while reducing energy costs. Especially, however, glare is the most important factor in daylighting, which is issued by incoming direct sunlight into windows. This study analyzed the discomfort glare on a daylighting window by using Image processing methodology and found a solution to problems with glare source of occupants. There are several ways to evaluate discomfort glare such as UGR (Unified Glare Rating) of CIE, DGI (Daylight Glare Index, Hopkinson, 1972) and VCP (Visual Comfort Probability) of IES. These are used to apply to the relatively little artificial light source and they cannot cover discomfort glare from a real daylighting window. In this regarding, this paper aimed to calculate DGI index of the real daylighting window in a experimental space by using image processing methodology. The variables and outcomes are luminance distribution of non-shading window, effect of venetian blind installed on the window and locations related to position index of DGI.