• Title/Summary/Keyword: Data logger

Search Result 177, Processing Time 0.032 seconds

Displacement Current in a Parallel Plate Capacitor Biased by DC Voltages (직류전압을 건 평행판 축전기에서 변위전류 고찰)

  • Kim, Jae-Dong;Jang, Taehun;Ha, Hye Jin;Sohn, Sang Ho
    • Journal of Science Education
    • /
    • v.45 no.2
    • /
    • pp.219-230
    • /
    • 2021
  • In this study, we derived several formulas for magnetic fields and induced voltages in a parallel plate capacitor biased by DC voltages. The computer simulation based on the derived formulas reveals that the magnetic fields due to the displacement current fall within the range of 10-10T to 10-9T and thence the experiment for the displacement current is not possible because the magnetic field sensor used in Data Logger could measure the magnetic fields of above 10-5T range. Contrary to this, the computer simulation confirms that the induced voltages in a toroidal coil due to the displacement current range measurable values of 0.002~0.021V. The results imply that the displacement current can be confirmed by measuring the induced voltages in a toroidal coil inserted into a parallel plate capacitor under DC biasing.

Development of ECG Monitoring System on Mobile Platform (모바일 기반의 심전도 모니터링 시스템 개발)

  • Kim M.H.;Yoon J.H.;Lee T.Y.;Lee S.R.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.265-266
    • /
    • 2006
  • In this paper, the ECG monitoring system on mobile platform was proposed, which is very useful to gather, storage and diagnose ECG signal. The existing ECG monitoring system is for indoor environment but this system is for outdoor environment, especially for automobile system. The developed system consisted of data logger using microprocessor and data server fur diagnosis ECG signal. We develop the data acquisition system hardware and data monitoring system for ECG signal.

  • PDF

Water loss Control in DMA Monitoring System Used Wireless Technology

  • Malithong, P.;Gulphanich, S.;Suesut, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.773-777
    • /
    • 2005
  • This article is about using information technology to apply with water loss inspection system in District Metering Area (DMA). Inspector can check Flow rate and Minimum Night Flow; NMF via Smart Phone or PDA include sending SMS Alert in case the Pressure, Flow rate and NMF is over the range of controlling. This will be used as equipment to implement water loss in international proactive and can keep on water loss reduction more efficiency. The system consists of Data Logger which collects data of Flow rate from DMA Master Meter. PC is Wap Server which dial via modem in order to get data through FTP Protocal that will convert text file to Microsoft Access Database. Wappage will use xhtml language to show database on Wapbrowser and can show the result on Smart Phone or PDA by graph and table for system analysis.

  • PDF

Development of Battle Space Model Based on Combined Discrete Event and Discrete Time Simulation Model Architecture for Underwater Warfare Simulation (수중운동체 교전 시뮬레이션을 위한 이산 사건 및 이산 시간 혼합형 시뮬레이션 모델 구조 기반의 전투 공간 모델 개발)

  • Ha, Sol;Ku, Namkug;Lee, Kyu-Yeul;Roh, Myung-Il
    • Journal of the Korea Society for Simulation
    • /
    • v.22 no.2
    • /
    • pp.11-19
    • /
    • 2013
  • This paper presents the battle space model, which is capable of propagating various types of emissions from platforms in underwater warfare simulation, predicting interesting encounters between pairs of platforms, and managing environmental information. The battle space model has four components: the logger, spatial encounter predictor (SEP), propagator, and geographic information system (GIS) models. The logger model stores brief data on all the platforms in the simulation, and the GIS model stores and updates environmental factors such as temperature and current speed. The SEP model infers an encounter among the platforms in the simulation, and progresses the simulation to the time when this encounter will happen. The propagator model receives various emissions from platforms and propagates these to other "within-range" platforms by considering the propagation losses and delays. The battle space model is based on the discrete event system specification (DEVS) and the discrete time system specification (DTSS) formalisms. To verify the battle space model, simple underwater warfare between a battleship and a submarine was simulated. The simulation results with the model were the same as the simulation results without the model.

Development of Underwater Positioning System using Asynchronous Sensors Fusion for Underwater Construction Structures (비동기식 센서 융합을 이용한 수중 구조물 부착형 수중 위치 인식 시스템 개발)

  • Oh, Ji-Youn;Shin, Changjoo;Baek, Seungjae;Jang, In Sung;Jeong, Sang Ki;Seo, Jungmin;Lee, Hwajun;Choi, Jae Ho;Won, Sung Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.352-361
    • /
    • 2021
  • An underwater positioning method that can be applied to structures for underwater construction is being developed at the Korea Institute of Ocean Science and Technology. The method uses an extended Kalman filter (EKF) based on an inertial navigation system for precise and continuous position estimation. The observation matrix was configured to be variable in order to apply asynchronous measured sensor data in the correction step of the EKF. A Doppler velocity logger (DVL) can acquire signals only when attached to the bottom of an underwater structure, and it is difficult to install and recover. Therefore, a complex sensor device for underwater structure attachment was developed without a DVL in consideration of an underwater construction environment, installation location, system operation convenience, etc.. Its performance was verified through a water tank test. The results are the measured underwater position using an ultra-short baseline, the estimated position using only a position vector, and the estimated position using position/velocity vectors. The results were compared and evaluated using the circular error probability (CEP). As a result, the CEP of the USBL alone was 0.02 m, the CEP of the position estimation with only the position vector corrected was 3.76 m, and the CEP of the position estimation with the position and velocity vectors corrected was 0.06 m. Through this research, it was confirmed that stable underwater positioning can be carried out using asynchronous sensors without a DVL.

The Development of the Monitoring System for Power performance using the Lab View (LabView를 이용한 풍력발전 성능평가용 모니터링 시스템 개발)

  • Ko, Seok-Whan;Jang, Moon-Seok;Ju, Young-Chul;Lee, Yoon-Sub
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.6
    • /
    • pp.69-74
    • /
    • 2009
  • Monitoring system is an absolutely-required system for assessing a performance and fatigue load of the wind turbine in an on-shore wind energy experimental research complex. It was implemented for the purpose of monitoring the wind information measured from a meteorological tower at the monitoring house, and of utilizing the measured data(fatigue data and electric analyzing data of wind turbine)for the performance assessment, by using the LabVIEW program. Then, by adding the performance assessment-related data acquired from the wind turbine during the performance assessment and the data recorder for synchronizing the data of meteorological tower, the system(BusDAQ) was implemented. Because it transmitted the data by converting the output 'RS-232' of data logger which measures the wind condition into CAN protocol, the data error rate was minimized. Also, This paper is introduced to make the best use of the developed monitoring system and to explain about construct of the system and detailed data communication of its system.

Design and Implementation of Seismic Data Acquisition System using MEMS Accelerometer (MEMS형 가속도 센서를 이용한 지진 데이터 취득 시스템의 설계 및 구현)

  • Choi, Hun;Bae, Hyeon-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.851-858
    • /
    • 2012
  • In this paper, we design a seismic data acquisition system(SDAS) and implement it. This system is essential for development of a noble local earthquake disaster preventing system in population center. In the system, we choose a proper MEMS-type triaxial accelerometer as a sensor, and FPGA and ARM processor are used for implementing the system. In the SDAS, each module is realized by Verilog HDL and C Language. We carry out the ModelSim simulation to verify the performances of important modules. The simulation results show that the FPGA-based data acquisition module can guarantee an accurate time-synchronization for the measured data from each axis sensor. Moreover, the FPGA-ARM based embedded technology in system hardware design can reduce the system cost by the integration of data logger, communication sever, and facility control system. To evaluate the data acquisition performance of the SDAS, we perform experiments for real seismic signals with the exciter. Performances comparison between the acquired data of the SDAS and the reference sensor shows that the data acquisition performance of the SDAS is valid.

A Study on the Development of Remotely CP Potential Measuring Method by using Vehicle (차량을 이용한 원격전위 측정방법 개발에 관한 연구)

  • Ryou, Young-Don;Jo, Young-Do;Kim, Jin-Jun;Seo, Min-Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.5
    • /
    • pp.64-71
    • /
    • 2016
  • According to the urban gas business law, electrical corrosion prevention measures shall be installed to the buried gas pipelines and the pipe-to-soil potentials should be measured at the test box at least once a year. Most of the test boxes installed in urban area are usually located on the road where the vehicle travels, therefore, it is difficult to measure the CP potentials at the test boxes. That is, we need traffic control when carrying out the measurement of the CP potentials on daytime when the traffic is heavy, or we have to measure the potentials in the late night when the traffic is light. To solve these difficulties, we have studied remotely CP potential measuring method by using the patrol car. We have installed solid reference electrodes and data loggers under the test boxes on the site and received the CP potentials from the data loggers when the vehicle moves. It was difficult to send and receive the data because the data logger was located under the ground. We have applied 3 different method including 2 antenna systems to achieve best effective way in receiving the data. We have found the remote CP measuring method by using a car can save more 20 times of measuring time than conventional measuring methods.

Experimental Study on Heat Losses from Receiver of Solar Thermal Power (태양열발전용 흡수기 설게 및 열손실 특성실험)

  • Kim, Jong-Kyu;Kang, Yong-Heack;Kim, Jin-Soo;Lee, Sang-Nam;Yu, Chang-Kyun;Yun, Hwan-Ki
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.672-675
    • /
    • 2007
  • Experimental data are presented which describe heat losses of cavity type receiver in wind tunnel. Experiments are conducted at various conditions such as the heater temperature in cavity changes from 300, 400, and 500 oC, wind speed in tunnel from 2 to 8 m/s, and four different tilt angle of 30, 50, 70, 90o. The power consumption including temperature, voltage and current for each experimental conditions are measured and stored in data logger at everyone second interval. The experimental results show that heat losses increase with increasing wind speed and with tilt angle. However, heat losses for the tilt angle of 70 and 90o is almost same at each heater temperature. In addition, the effects of natural convection in combined convection heat losses vary in according to the tilt angle.

  • PDF

Development of a Load Spectrum of Tractor Transmission (트랙터 변속기의 부하 스펙트럼 개발)

  • 김대철;김경욱;이주완
    • Journal of Biosystems Engineering
    • /
    • v.23 no.6
    • /
    • pp.539-548
    • /
    • 1998
  • This study was intended to develop a load spectrum acting on a transmission of agricultural tractors. Transmission loads were measured at the input shaft of the transmission and final drive shaft of the tractors. The measurement were conducted in five field conditions at two speed levels under plowing operations in Korea. Two torque transducers were developed for the respective load measurements and other necessary instrumentations were made to collect the data and store them in a data logger. The time-histories of the torque loads were analyzed and transformed into the load spectra using the rainflow counting and Smith-Watson-Topper methods. Comparisons of the load spectra developed under different conditions were made to investigate their characteristics. The effects on the load levels of soil and plowing speeds were also investigated. Finally, a load spectrum combining the results of the spectrum analysis was developed and proposed as a load source for the reliability test of transmissions.

  • PDF