A Study on the Development of Remotely CP Potential Measuring Method by using Vehicle  

Ryou, Young-Don (Korea Gas Safety Corporation)
Jo, Young-Do (Korea Gas Safety Corporation)
Kim, Jin-Jun (Hoseo University)
Seo, Min-Sung (SOFTLAB Co.,Ltd.)
Publication Information
Journal of the Korean Institute of Gas / v.20, no.5, 2016 , pp. 64-71 More about this Journal
Abstract
According to the urban gas business law, electrical corrosion prevention measures shall be installed to the buried gas pipelines and the pipe-to-soil potentials should be measured at the test box at least once a year. Most of the test boxes installed in urban area are usually located on the road where the vehicle travels, therefore, it is difficult to measure the CP potentials at the test boxes. That is, we need traffic control when carrying out the measurement of the CP potentials on daytime when the traffic is heavy, or we have to measure the potentials in the late night when the traffic is light. To solve these difficulties, we have studied remotely CP potential measuring method by using the patrol car. We have installed solid reference electrodes and data loggers under the test boxes on the site and received the CP potentials from the data loggers when the vehicle moves. It was difficult to send and receive the data because the data logger was located under the ground. We have applied 3 different method including 2 antenna systems to achieve best effective way in receiving the data. We have found the remote CP measuring method by using a car can save more 20 times of measuring time than conventional measuring methods.
Keywords
Cathodic Protection System; Remote CP Measurement; Data Logger; Reference Electrode;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 KETE, "Development of solid reference electrode and testing system for cathodic protection of underground pipelines based on IoT", (2013)
2 Antenna Terminology Defined http://www.mobilemark.com/engineering/antenna-terminologydefined/
3 Hosokawa, Y., "Cathodic Protection Management", International seminar, (2014)
4 KGS GC202 Code for Cathodic Protection of Gas Facilities, (2015)
5 Ryou, Y. D., Kim, J. H., Jo, Y. D., and Kim, J. J., "A Study on the Amendments of the Cathodic Protection Criteria Considering IR Drops", KIGAS, Vol 20, No. 4, 50-57, (2016)
6 Ryou, Y. D., Kim, J. J., and Kim, D, K., "A Study on the Development of Solid Reference Electrode and Remote Protection Potential Measuring System", KIGAS, Vol 19, No. 3, 38-43, (2015)
7 Kim, J. J., Seo M. S., and Kim, D. K., "A Study on Development of Cathodic Protection on Underground Pipeline Measuring System", KIGAS, Vol 18, No. 5, 66-71, (2014)
8 Ryou, Y. D., Kim, J. H., Jo, Y. D., Kim, J. J., and Kim, D. K., "Development of a Remote Cathodic Protection Potential Measuring System Based on the IoT", PTC conference, (2016)
9 AS 2832.1, "Cathodic protection of metals - Part 1 : Pipes and cables", (2004)