• Title/Summary/Keyword: Data Value Analysis

Search Result 7,427, Processing Time 0.049 seconds

A Study on Health Status of the 1,559 Korean Applicants Applying for the Coal Miners in West Germany during the Year of 1972 and 1973 (우리나라 독일광부(獨逸鑛夫) 지원자(志願者)에 대(對)한 건강상태(健康狀態)에 관(關)한 조사연구(調査硏究))

  • Jun, Hyun-Sook;Choi, Sam-Sup
    • Journal of Preventive Medicine and Public Health
    • /
    • v.7 no.2
    • /
    • pp.383-393
    • /
    • 1974
  • The importance of the health care for the miners not only concerns the productivity of the enterprises but also as a fundamental human right, it has to be secured and protected by the society and the government. The Korean coal miners began to find their works at overseas since 1963 when the Korean government selected and dispatched its miners to West Germany. As years go by, the demand and the supply of the coal miners, the program of the coal miners health care became the important tasks to be solved and the further studies and research were necessary to support these tasks achievement. The writers made a statistical analysis on health status of the 1,559 Korean applicants applying for the coal miners in West Germany during the year of 1972 and 1973 by the using of the data of physical examination which were directed by the Korea Overseas Development Cooperation. The standard of physical examination which was applied for coal miners applying the jobs in West Germany was authorized by the Government Office of Labor in 1967. The results are as following; 1. The applicants were from the various provinces throughout Korea; Gang Weon 50.2%, Jeon-Nam 16.8%, Chung-Nam 13.7%, Gyeong-Nam 10.5%, City of Seoul 5.4%, and others 3.7%. 2. The ages of the applicants were from 20 to 44. The age group of 25-29(36.3%) and of 30-34(55.2%) together occupied the 91.5 per cent of the total applicants. 3. Among the 1,559 applicants 52.1 per cent passed the physical examinations. The tendency were shown that as the age increased, the passing rate decreased, and the married applicnts had lower passing rates compared to the unmarried applicants. 4. The height of the applicants averaged $168.4{\pm}4.74(cm)$ and the weight averaged $61.3{\pm}5.65(kg)$. 5. The average vision of the left eye of the applicants was $0.92{\pm}0.23$ and the right eye was $0.91{\pm}0.30$. 6. The mean value of the systolic blood pressure of the applicants was $145{\pm}13(mmHg)$ and the diastolic blood pressure was $85{\pm}8(mmHg)$. 7. Fifteen hundred and fifty-nine applicants were taken chest X-ray and 17.2 per cent were found abonrmal. For each 1,000 applicants, 46 Pulmonary calcification and fibrosis, 45 chronic bronchitis, 27 pleural thickening and adhesion, 20 pulmonary tuburculosis, 11 anomalies of the rib, 10 pulmonary infiltration and 21 others diseases were found. 8. Lumber X-ray examination showed that 23.9 per cent (372 applicants) were found abnormal. For each 1,000 applicants, 77 osteoarthritis, 56 lumbarization, 15 fracture of vertebrae, 15 spondyloarthritis, 14 deformity of vertebrae, 13 spina bifida, 12 sacralization, 12 spondylolysis, and 5 others diseases were found. 9. In total, 47.9 per cent of 1,559 applicants failed the physical examinations, and the main causes for the failure were shown to be 7.1% of anomalies of spine, 6.3% of osteoarthritis, 4.7% of pulmonary calcification and fibrosis, 4.6% of chronic brochitis, 3.6% of hypertension (only), 3.4% of fracture of vertebrae. 3.1% of underweight(under 57.0kg), 2.0% of spondyloarthritis, 2.0% oe pulmonary tuberculosis, 1.7% of pleurisy, 1.0% of spina bifida, 1.5% of syphilis, 1.5% of color blindess, and 1.0% of underheight(under 160.0cm).

  • PDF

GnRH Agonist Stimulation Test (GAST) for Prediction of Ovarian Response in Controlled Ovarian Stimulation (COH) (난소기능평가를 위한 Gonadotropin Releasing Hormone Agonist Stimulation Test (GAST)의 효용성에 관한 연구)

  • Kim, Mee-Ran;Song, In-Ok;Yeon, Hye-Jeong;Choi, Bum-Chae;Paik, Eun-Chan;Koong, Mi-Kyoung;Song, Il-Pyo;Lee, Jin-Woo;Kang, Inn-Soo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.26 no.2
    • /
    • pp.163-170
    • /
    • 1999
  • Objectives: The aims of this study are 1) to determine if GAST is a better indicator in predicting ovarian response to COH compared with patient's age or basal FSH level and 2) to evaluate its role in detecting abnormal ovarian response. Design: Prospective study in 118 patients undergoing IVF-ET using GnRH-a short protocol during May-September 1995. Materials and Methods: After blood sampling for basal FSH and estradiol $(E_2)$ on cycle day two, 0.5ml (0.525mg) GnRH agonist ($Suprefact^{(r)}$, Hoechst) was injected subcutaneously. Serum $E_2$ was measured 24 hours later. Initial $E_2$ difference $({\Delta}E_2)$ was defined as the change in $E_2$ on day 3 over the baseline day 2 value. Sixteen patients with ovarian cyst or single ovary or incorrect blood collection time were excluded from the analysis. The patients were divided into three groups by ${\Delta}E_2$; group A (n=30):${\Delta}E_2$<40 pg/ml, group B (n=52): 40 pg/ml${\leq}{\Delta}E_2$<100 pg/ml, group C (n=20): ${\Delta}E_2{\leq}100$ pg/ml. COH was done by GnRH agonist/HMG/hCG and IVF-ET was followed. Ratio of $E_2$ on day of hCG injection over the number of ampules of gonadotropins used ($E_2hCGday$/Amp) was regarded as ovarian responsiveness. Poor ovarian response and overstimulation were defined as $E_2$ hCGday less than 600 pg/ml and greater than 5000 pg/ml, respectively. Results: Mean age $({\pm}SEM)$ in group A, B and C were $33.7{\pm}0.8^*,\;31.5{\pm}0.6\;and\;30.6{\pm}0.5^*$, respectively ($^*$: p<0.05). Mean basal FSH level of group $A(11.1{\pm}1.1mlU/ml)$ was significantly higher than those of $B(7.4{\pm}0.2mIU/ml)$ and C $(6.8{\pm}0.4mIU/ml)$ (p<0.001). Mean $E_2hCGday$ of group A was significantly lower than those of group B or C, i.e., $1402.1{\pm}187.7pg/ml,\;3153.2{\pm}240.0pg/ml,\;4078.8{\pm}306.4pg/ml$ respectively (p<0.0001). The number of ampules of gonadotropins used in group A was significantly greater than those in group B or C: $38.6{\pm}2.3,\;24.2{\pm}1.1\;and\;18.5{\pm}1.0$ (p<0.0001). The number of oocytes retrieved in group A was significantly smaller than those in group B or C: $6.4{\pm}1.1,\;15.5{\pm}1.1\;and\;18.6{\pm}1.6$, respectively (p<0.0001). By stepwise multiple regression, only ${\Delta}E_2$ showed a significant correlation (r=0.68, p<0.0001) with $E_2HCGday$/Amp, while age or basal FSH level were not significant. Likewise, only ${\Delta}E_2$ correlated significantly with the number of oocytes retrieved (r=0.57, p<0.001). All four patients whose COH was canceled due to poor ovarian response belonged to group A only (Fisher's exact test, p<0.01). Whereas none of 30 patients in group A (0%) had overstimulation, 14 patients among 72 patients (19.4%) in group B and C had overstimulation (Fisher's exact test, p<0.01). Conclusions: These data suggest that initial $E_2$ difference after GAST may be a better prognostic indicator of ovarian response to COH than age or basal FSH level. Since initial $E_2$ difference demonstrates significant association with abnormal ovarian response such as poor ovarian response necessitating cycle cancellation or overstimulation, GAST may be helpful in monitoring and consultation of patients during COH in IVF-ET cycle.

  • PDF

Analysis of the Mean Uranium Valence of $U_{1-y}Er_{y}O_{2{\pm}x}$ Solid Solutions in terms of Lattice Parameter and Oneen Potential (격자상수 및 산소포텐샬에 의한 $U_{1-y}Er_{y}O_{2{\pm}x}$ 고용체의 평균우라늄원자가 분석)

  • Kim, Han-Soo;Sohn, Dong-Seong
    • Nuclear Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.118-128
    • /
    • 1996
  • The lattice parameters of stoichiometric $UO_2$ and $U_{1-y}Er_{y}O_2$ in the range of y=0.01 to y =0.33 were determined with use of X-ray diffraction data. Oxygen potentials have been measured by means of a thermogravimetric method in the range of 1200~$1500^{\circ}C$ and $10^{-14}$ $\leq$ $Po_2$ $\leq$ $10^{-3}$ for pure $UO_2$ and $U_{1-y}Er_{y}O_{2{\pm}x}$ solid solutions with y=0.02, y=0.06 and y=0.20, respectively. Their oxygen partial pressures were maintained by controlling $CO_2$/CO mixture atmosphere, and the $Po_2$ values corresponding to x of $U_{1-y}Er_{y}O_{2{\pm}x}$ solid solutions were measured with an electrolyte oxygen sensor. The lattice parameter decreases linearly with an increase in the erbium content. The change of the lattice parameter can be expressed in a linear equation of y as a($\AA$) =5.4695-0.220y for 0 $\leq$y$\leq$0.33. The experimental coefficient of y -0.220 in $U_{1-y}Er_{y}O_2$ was an intermediate value between the calculated values -0.273 and -0.156 in the case of $U^{5+}$ and $U^{6+}$, respectively. The (equation omitted) has been found to undergo abrupt increase in the range of -360 to -270 kJ/mole for y=0.06 and -320 to -220 H/mole for y=0.20, respectively, in the temperature range of 1200-$1500^{\circ}C$. (equation omitted) increases with erbium content, but the effect of the dopant for x =0.01 is less significant than that for stoichiometry. The oxygen potentials for $UO_2$ and $U_{0.98}Er_{0.02}O_{2+x}$ can be approximately represented by the $U^{5+}$/$U^{4+}$ model but those for y$\geq$ 0.06 in $U_{1-y}Er_{y}O_{2{\pm}x}$ solid solutions cannot be interpreted by the mean uranium valence model.

  • PDF

The Influence of Iteration and Subset on True X Method in F-18-FPCIT Brain Imaging (F-18-FPCIP 뇌 영상에서 True-X 재구성 기법을 기반으로 했을 때의 Iteration과 Subset의 영향)

  • Choi, Jae-Min;Kim, Kyung-Sik;NamGung, Chang-Kyeong;Nam, Ki-Pyo;Im, Ki-Cheon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.122-126
    • /
    • 2010
  • Purpose: F-18-FPCIT that shows strong familiarity with DAT located at a neural terminal site offers diagnostic information about DAT density state in the region of the striatum especially Parkinson's disease. In this study, we altered the iteration and subset and measured SUV${\pm}$SD and Contrasts from phantom images which set up to specific iteration and subset. So, we are going to suggest the appropriate range of the iteration and subset. Materials and Methods: This study has been performed with 10 normal volunteers who don't have any history of Parkinson's disease or cerebral disease and Flangeless Esser PET Phantom from Data Spectrum Corporation. $5.3{\pm}0.2$ mCi of F-18-FPCIT was injected to the normal group and PET Phantom was assembled by ACR PET Phantom Instructions and it's actual ratio between hot spheres and background was 2.35 to 1. Brain and Phantom images were acquired after 3 hours from the time of the injection and images were acquired for ten minutes. Basically, SIEMENS Bio graph 40 True-point was used and True-X method was applied for image reconstruction method. The iteration and Subset were set to 2 iterations, 8 subsets, 3 iterations, 16 subsets, 6 iterations, 16 subsets, 8 iterations, 16 subsets and 8 iterations, 21 subsets respectively. To measure SUVs on the brain images, ROIs were drawn on the right Putamen. Also, Coefficient of variance (CV) was calculated to indicate the uniformity at each iteration and subset combinations. On the phantom study, we measured the actual ratio between hot spheres and back ground at each combinations. Same size's ROIs were drawn on the same slide and location. Results: Mean SUVs were 10.60, 12.83, 13.87, 13.98 and 13.5 at each combination. The range of fluctuation by sets were 22.36%, 10.34%, 1.1%, and 4.8% respectively. The range of fluctuation of mean SUV was lowest between 6 iterations 16 subsets and 8 iterations 16 subsets. CV showed 9.07%, 11.46%, 13.56%, 14.91% and 19.47% respectively. This means that the numerical value of the iteration and subset gets higher the image's uniformity gets worse. The range of fluctuation of CV by sets were 2.39, 2.1, 1.35, and 4.56. The range of fluctuation of uniformity was lowest between 6 iterations, 16 subsets and 8 iterations, 16 subsets. In the contrast test, it showed 1.92:1, 2.12:1, 2.10:1, 2.13:1 and 2.11:1 at each iteration and subset combinations. A Setting of 8 iterations and 16 subsets reappeared most close ratio between hot spheres and background. Conclusion: Findings on this study, SUVs and uniformity might be calculated differently caused by variable reconstruction parameters like filter or FWHM. Mean SUV and uniformity showed the lowest range of fluctuation at 6 iterations 16 subsets and 8 iterations 16 subsets. Also, 8 iterations 16 subsets showed the nearest hot sphere to background ratio compared with others. But it can not be concluded that only 6 iterations 16 subsets and 8 iterations 16 subsets can make right images for the clinical diagnosis. There might be more factors that can make better images. For more exact clinical diagnosis through the quantitative analysis of DAT density in the region of striatum we need to secure healthy people's quantitative values.

  • PDF

Usefulness of Region Cut Subtraction in Fusion & MIP 3D Reconstruction Image (Fusion & Maximum Intensity Projection 3D 재구성 영상에서 Region Cut Subtraction의 유용성)

  • Moon, A-Reum;Chi, Yong-Gi;Choi, Sung-Wook;Lee, Hyuk;Lee, Kyoo-Bok;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.18-23
    • /
    • 2010
  • Purpose: PET/CT combines functional and morphologic data and increases diagnostic accuracy in a variety of malignancies. Especially reconstructed Fusion PET/CT images or MIP (Maximum Intensity Projection) images from a 2-dimensional image to a 3-dimensional one are useful in visualization of the lesion. But in Fusion & MIP 3D reconstruction image, due to hot uptake by urine or urostomy bag, lesion is overlapped so it is difficult that we can distinguish the lesion with the naked eye. This research tries to improve a distinction by removing parts of hot uptake. Materials and Methods: This research has been conducted the object of patients who have went to our hospital from September 2008 to March 2009 and have a lot of urine of remaining volume as disease of uterus, bladder, rectum in the result of PET/CT examination. We used GE Company's Advantage Workstation AW4.3 05 Version Volume Viewer program. As an analysis method, set up ROI in region of removal in axial volume image, select Cut Outside and apply same method in coronal volume image. Next, adjust minimum value in Threshold of 3D Tools, select subtraction in Advanced Processing. It makes Fusion & MIP images and compares them with the image no using Region Cut Definition. Results: In Fusion & MIP 3D reconstruction image, it makes Fusion & MIP images and compares them by using Advantage Workstation AW4.3 05's Region Cut Subtraction, parts of hot uptake according to patient's urine can be removed. Distinction of lesion was clearly reconstructed in image using Region Cut Definition. Conclusion: After examining the patients showing hot uptake on account of volume of urine intake in bladder, in process of reconstruction image, if parts of hot uptake would be removed, it could contribute to offering much better diagnostic information than image subtraction of conventional method. Especially in case of disease of uterus, bladder and rectum, it will be helpful for qualitative improvement of image.

  • PDF

Usefulness of Flow Composite Image in Raynaud Scan ($^{201}Tl$) ($^{201}Tl$을 이용한 레이노 검사에서 동적 Composite 영상의 유용성)

  • Kim, Dae-Yeon;Shin, Gyoo-Seol;Oh, Eun-Jung;Kim, Gun-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.101-104
    • /
    • 2010
  • Purpose: Raynaud scan is divided to flow, blood pool and local-delay image. Usually, we evaluate comparison through blood pool and local-delay image. We will evaluate about usability when comparative observe blood image and local-delay image in Raynaud scan that used $^{201}Tl$ as making flow image to one sheet of images. Materials and Methods: We have selected 29 Raynaud phenomenon patients aged 14~68 years who visited department of vascular surgery between Feb. 2008 and Aug. 2009. An intravenous injection $^{201}Tl$ of 111 MBq (3 mCi) to opposite side diagonal line limbs above an internal auditing department. Equipment used Philips gamma camera forte A-Z, and collimator used LEHR. Matrix size set up to each $64{\times}64$, $128{\times}128$, $256{\times}256$ and zoom factor used to full field. Protocol of dynamic is 2 second to 155 frames. Blood pool and delay count to 300 second. We set up ROI by a foundation to data acquired in PEGASYS processing program. Each results were analyzed with the SPSS 12.0 statistical software. Results: Each averages of count ratio (Rt / Lt) to have been given at composite image, a blood pool image, delay images analyzed at Raynaud phenomenon patients is $1.25{\pm}0.39$, $1.20{\pm}0.33$, $1.11{\pm}0.17$. The sample analysis results of blood pool image and delay image contented itself with p<0.029. Also, there don't have been each difference, and blood pool image, delay image regarding composite image was able to know. Conclusion: We were able to give help for comparison to evaluate a blood pool image and a local delay image at the Raynaud scan which used $^{201}Tl$ while making a flow image to one sheet image. Identification to be visual too was possible. If you are proceeded a researcher that there was further depth, you are more appropriate for, and you may get useful information.

  • PDF

Signal to Noise Ratio of MR Spectrum by variation echo time : comparison of 1.5T and 3.0T (Echo time에 따른 MR spectrum의 SNR: 1.5T와 3.0T비교)

  • Kim, Sung-Gil;Lee, Kyu-Su;Rim, Che-Pyeong
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.401-407
    • /
    • 2011
  • The purpose of this study is to know the differences of MR spectra, obtained from normal volunteers by variable TE value, through the quantitative analysis of brain metabolites by peak integral and SNR between 1.5T and 3.0T, together with PRESS and STEAM pulse sequence. Single-voxel MR proton spectra of the human brain obtained from normal volunteers at both 3.0T MR system (Magnetom Trio, SIEMENS, Germany) and 1.5T MR system (Signa Twinspeed, GE, USA) using the STEAM and PRESS pulse sequence. 10 healthy volunteers (3.0T:3 males, 2 females; 1.5T : 3 males, 2 females) with the range from 22 to 30 years old (mean 26 years) participated in our study. They had no personal or familial history of neurological diseases and had a normal neurological examination. Data acquisition parameters were closely matched between the two field strengths. Spectra were recorded in the white matter of the occipital lobe. Spectra were compared in terms of resolution and signal-to-noise ratio(SNR), and echo time(TE) were estimated at both field strengths. Imaging parameters was used for acquisition of the proton spectrum were as follow : TR 2000msec, TE 30ms, 40ms, 50ms, 60ms, 90ms, 144ms, 288ms, NA=96, VOI=$20{\times}20{\times}20mm3$. As the echo times were increased, the spectra obtained from 3.0T and 1.5T show decreased peak integral and SNR at both pulse sequence. PRESS pulse sequence shows higher SNR and signal intensity than those of STEAM. Especially, Spectra in normal volunteers at 3.0T demonstrated significantly improved overall SNR and spectral resolution compared to 1.5T(Fig1). The spectra acquired at short echo time, 3T MR system shows a twice improvement in SNR compared to 1.5T MR system(Table. 1). But, there was no significant difference between 3.0Tand 1.5T at long TE It is concluded that PRESS and short TE is useful for quantification of the brain metabolites at 3.0T MRS, our standardized protocol for quantification of the brain metabolites at 3.0T MRS is useful to evaluate the brain diseases by monitoring the systematic changes of biochemical metabolites concentration in vivo.

Determination of Short Term Prognosis Among Chronic Obstructive Lung Disease with Acute Respiratory Failure According to Simplified Acute Physiology Score (만성 폐쇄성 폐질환에서 급성 호흡부전 발생시 Simplifed Acute Physiology Score에 따른 단기예후의 평가)

  • Lee, Sang-Pyo;Sung, Yun-Up;Kim, Sang-Hoon;Kim, Bong-Sik;Kim, Young-Jun;Park, In-Won;Choi, Byung-Whui;Hue, Sung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.5
    • /
    • pp.532-539
    • /
    • 1993
  • Background: Physician's estimates of patient survival often influence clinical decisions, especially those near the end of life. In addition. clinical decisions frequently reflect trade-offs between morbidity and length of survival. As a result, accurate estimates of survival can be extremely useful in clinical decision. When the episode of acute respiratory failure in chronic obstructive lung disease, evaluation of the severity of the condition and short term prognosis is difficulit based on the available clinical or paraclinical data at the time of admission. Method: In this study, we performed a retrospective study in Chung Ang University Hospital, 74 patients (51 males, 23 females), who were hospitalized with chronic obstructive lung disease with acute respiratory failure from 1980 to 1992. We evaluated these patients to determine lung prognostic factors at time of admission in the Intensive Care Unit (ICU) that predict short term survival, and to determine the possible application of the Simplified Acute Phsiology Score (SAPS) to this population, All patients were treated with similar regimen during the hospitalization. Results: The results were as follows: 1) Hospital mortality was 34%(25/74 patients) and surival rate was 66%(49/74 patients) in COPD with acute respiratory failure. The prognosis of the older age was much poorer than those of the young age. 2) There was no difference in mortality according to the results of basal pulmonary test and arterial blood gas analysis. 3) The SAPS at admission was higher in those patients who expired(10.8) than the survived(6.5), and there was positive correlation between SAPS and mortality (r=0.91, p<0.05). 4) Prognostic factors in acute respiratory failure complicating COPD which were identifiable at time of admission to the ICU were as follows: cachexia, encephalopathy, serum creatinine and phosphate. Conclusion: In conclusion, the SAPS might have a good prognostic value for determination of short term survival among chronic obstructive lung disease with acute respiratory failure.

  • PDF

Utility of CoaguChek XS for Monitoring the Prothrombin Time (프로트롬빈시간 모니터링을 위한 CoaguChek XS의 유용성)

  • Park, Rojin;Kim, Yong-Hyun;Kwon, Kyung Ock;Na, Jongsung;Won, Yong Soon;Sung, Ki Bum;Lee, Nae-Hee;Choi, Tae Youn;Shin, Jeong Won;Shin, Hee Bong;Lee, Yong-Wha;Lee, You Kyeong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.65 no.6
    • /
    • pp.471-475
    • /
    • 2008
  • Background: In order to achieve a maintenance level and to prevent hemorrhagic complications, regular monitoring of the INR is mandatory for patients on oral anticoagulation therapy (OAT). A point-of-care instrument for INR monitoring is convenient for users, but the accuracy of the results has been controversial, and so this calls for exact evaluation of the point-of-care instrument that is used for INR monitoring. Methods: From Aug 2007 through Feb 2008, 85 patients on OAT among the all the patients who were admitted to Soonchunhyang University Bucheon Hospital were involved in this study. Parallel measurements of the PT INR were performed using a CoaguChek-XS and, a CA-7000 laboratory reference instrument and the results were analyzed. In addition, the patients' clinical data, including the diagnosis and the frequency and interval of the INR measurements, were also analyzed. Results: Of the 85 patients, 25 were admitted more than once to undergo INR testing and the mean interval between testing was 8.6 weeks with 39% and 38% of the tests being less than INR 2 units with using the CoaguChek-XS and the reference method, respectively. The coefficients of variation of CoaguChek-XS were 4.50 and 2.45 for the high and low INR patients, respectively. An excellent correlation was found between the two methods with a $R^2$ of 0.966 (p<0.001). Through Bland-Altman analysis, the mean INR difference between the two methods was 0.13 with the limit of agreement being -0.47~+0.72 with a 95% confidence interval. CoaguChek-XS was shown to overestimate the INR value for patients with an increasing INR, as compared to the reference method. Conclusion: CoaguChek-XS demonstrated great precision and accuracy for patients on OAT when compared to the laboratory INR results. Accordingly, the instrument should help to monitor the INR in the patients on OAT.

Influence of bone loss pattern on stress distribution in bone and implant: 3D-FEA study (주변 골흡수 양상에 따른 임플란트와 골의 응력분산에 관한 유한요소 분석)

  • Lee, Jong-Hyuk;Kim, Sung-Hun;Lee, Jae-Bong;Han, Jung-Suk;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.111-121
    • /
    • 2010
  • Purpose: This 3D-FEA study was performed to investigate the influence of marginal bone loss pattern around the implant to the stress distribution. Material and methods: From the right second premolar to the right second molar of the mandible was modeled according to the CT data of a dentate patient. Teeth were removed and an implant ($\Phi\;4.0{\times}10.0mm$) was placed in the first molar area. Twelve bone models were created; Studied bone loss conditions were horizontal bone loss and vertical bone loss, assumed bone loss patterns during biologic width formation, and pathologic vertical bone loss with or without cortification. Axial, buccolingual, and oblique force was applied independently to the center of the implant crown. The Maximum von Mises stress value and stress contour was observed and von Mises stresses at the measuring points were recorded. Results: The stress distribution patterns were similar in the non-resorption and horizontal resorption models, but differed from those in the vertical resorption models. Models assuming biologic width formation showed altered stress distribution, and weak bone to implant at the implant neck area seams accelerates stress generation. In case of vertical bone resorption, contact of cortical bone to the implant may positively affect the stress distribution.