• Title/Summary/Keyword: Daily Dose

Search Result 894, Processing Time 0.031 seconds

Superovulation in Rabbits with a Single Injection of FSH Dissolved in Polyvinylpyrrolidone (토끼에서 FSH제의 Single Injection에 따른 과배란유기 효과)

  • 최상용;노규진;최창용;강태영;윤희준;손우진;이효종;박충생
    • Journal of Embryo Transfer
    • /
    • v.11 no.3
    • /
    • pp.211-216
    • /
    • 1996
  • A series of experiments were designed to determine the feasibility of single dose of FSH as an effective superovulation method in rabbits. The superovulation treatments examined comparatively were as follows: 1) a single injection of 100 IU PMSG, 2) Multiple injections of 1 IU Super-OV of 2X daily for 3 days, 3) Multiple injections of 6.6 rng Folltropin-V 2X daily for 3 days, 4) Multiple injections of 13.3 rng Folltropn-V l$\times$ daily for 3 days, 5) Single injection of 40 mg Folltropin-V solved in 10% PVP, and 6) Single injection of 40 mg Folltropin-V dissolved in 25% PVP. The results obtained were as follows: The nurnher of ovulation points in the single injection of 40 mg Folltropin-V dissolved in 25% PVP and multiple injections of 6.6 mg Folltropin-V 2X daily for 3 days was averaged 44.6 and 39.2, respectively, which were significantly (P<0.05) more than in a single dose of PMSG or multiple doses of Super-OV. The number of total ova recovered in the single injection of 40 mg Folltropin-V dissolved in 25% PVP and multiple injections of 6.6 mg Folltropin-V 2X daily for 3 days was averaged 30.4 and 25.9, respectively, which were significantly (P<0.05) more than in the single dose of PMSG or multiple doses of Super-OV. A similar result was obtained for the number of fertilized ova recovered from the above six treatments. From the above results it was concluded that a single injection of 40 mg Folltropin-V dissolved in 25% PVP could be an effective and simple method for superovulation in rabbits.

  • PDF

A Smart Setup for Craniospinal Irradiation

  • Peterson, Jennifer L.;Vallow, Laura A.;Kim, Siyong;Casale, Henry E.;Tzou, Katherine S.
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.230-236
    • /
    • 2013
  • Our purpose is to present a novel technique for delivering craniospinal irradiation in the supine position using a perfect match, field-in-field (FIF) intrafractional feathering, and simple forward-optimization technique. To achieve this purpose, computed tomography simulation was performed with patients in the supine position. Half-beam, blocked, opposed, lateral, cranial fields with a collimator rotation were matched to the divergence of the superior border of an upper-spinal field. Fixed field parameters were used, and the isocenter of the upper-spinal field was placed at the same source-to-axis distance (SAD), 20 cm inferior to the cranial isocenter. For a lower-spinal field, the isocenter was placed 40 cm inferior to the cranial isocenter at a constant SAD. Both gantry and couch rotations for the lower-spinal field were used to achieve perfect divergence match with the inferior border of the upper-spinal field. A FIF technique was used to feather the craniospinal and spinal-spinal junction daily by varying the match line over 2 cm. The dose throughout the target volume was modulated using the FIF simple forward optimization technique to obtain homogenous coverage. Daily, image-guided therapy was used to assure and verify the setup. This supine-position, perfect match craniospinal irradiation technique with FIF intrafractional feathering and dose modulation provides a simple and safe way to deliver treatment while minimizing dose inhomogeneity.

Physical Dependence on DA-5018, a Non-narcotic Analgesic Agent (비 마약성 진통제 DA-5018의 신체의존성)

  • 강경구;김동환;백남기;김원배;양중익
    • Biomolecules & Therapeutics
    • /
    • v.4 no.3
    • /
    • pp.232-238
    • /
    • 1996
  • The physical dependence potency of DA-5018, a non-narcotic analgesic agent, was tested in mice dosed with 0.5 and 4 mg/kg/day for 2 months and daily increasing doses of 1, 2, 4, 6, 8 and 10 mg/kg over 10 days. Physical dependence was assessed taking natural withdrawal induced morphine-type abstinence (jumping, falling, biting or backward locomotion, rearing etc.) as well as barbiturates-type abstinence (body weight reduction, convulsion, ataxia etc.) into consideration. The results were compared with those after the same daily increasing doses of morphine. DA-5018 did not show evidence of physical dependence liability or abuse potential as measured by morphine-type or barbiturate-type abstinence signs following daily increasing or 2-month repeated administration. On the other hand, daily increasing doses of morphine produced physical dependence and the dependent state disappeared about 6 hours after the start of withdrawal signs. In the single dose suppression test, a single dose of morphine completely suppressed natural withdrawal signs that appeared in morphine-dependent animals. Therefore, these results indicate that DA-5018 does not have abuse potential and physical dependence liability.

  • PDF

The Usefulness Assessment of Verifying Daily Output by Using CHECKMATE$^{TM}$ (CHECKMATE$^{TM}$를 이용한 일일 출력 검증의 유용성 평가)

  • Cho, Han-Sang;Nam, Sang-Soo;Park, Hae-Jin;Kim, Mi-Hwa;Park, An-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.51-58
    • /
    • 2011
  • Purpose: In this study, we tried to check the usefulness of two Linear Accelerators, Clinac IX and 21EX (Varian, Palo Alto, CA), which are equipped in Ajou Medical Center. From 2008 to 2010, we evaluated the error range of Absolute Dose based on the daily output, which was measured by CHECKMATE$^{TM}$ (Sun Nuclear, Melbourne, FL). Materials and Methods: For Daily Q.A, photon beams of two linear accelerators, 21EX and IX (6 MV and 10 MV, respectively) were measured daily by using CHECKMATE$^{TM}$ just before the treatment began, while the absolute dose was measured biweekly by using water phantom. We analyzed the data of measured values from the daily Q.A and the absolute dose from 2008 to 2010 for 21EX, and from 2009 to 2010 for IX. We utilized Excel 2007 (Microsoft, USA) to evaluate Average, Standard deviation and Confidence level of the data. Furthermore, in order to check the measured values of CHECKMATE$^{TM}$ and the significance of absolute dose, each error value was compared and analyzed. Results: During the observation period, the output of two equipment's absolute dose increased in process of time and in both 6 MV and 10 MV, there was a similar increasing trend. In addition, the error rate of the measured value of CHECKMATE$^{TM}$ and the value of absolute dose were under 0.34, which means that there is a similarity relationship between the two measured values. After checking that the measured value of CHECKMATE$^{TM}$ increased, We measured the absolute dose to adjust that. When the error range was close to 2~3%, the number of changing the output was four for 21EX and three for IX. Conclusion: As a result of measuring and analyzing the daily output changes for two years by using CHECKMATE$^{TM}$, we could find that there is a significance between the output which we should obey during Q.A, and the measured value of absolute dose within the error tolerance of 2~3%. Thus, the use of CHECKMATE$^{TM}$ can be positively considered for more efficient and reliable daily output verification of linear accelerator. It can also be a good standard for other medical centers to understand the trends of linear accelerator and to refer to for the correction of each output.

  • PDF

Improving the Accuracy of a Heliocentric Potential (HCP) Prediction Model for the Aviation Radiation Dose

  • Hwang, Junga;Yoon, Kyoung-Won;Jo, Gyeongbok;Noh, Sung-Jun
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.4
    • /
    • pp.279-285
    • /
    • 2016
  • The space radiation dose over air routes including polar routes should be carefully considered, especially when space weather shows sudden disturbances such as coronal mass ejections (CMEs), flares, and accompanying solar energetic particle events. We recently established a heliocentric potential (HCP) prediction model for real-time operation of the CARI-6 and CARI-6M programs. Specifically, the HCP value is used as a critical input value in the CARI-6/6M programs, which estimate the aviation route dose based on the effective dose rate. The CARI-6/6M approach is the most widely used technique, and the programs can be obtained from the U.S. Federal Aviation Administration (FAA). However, HCP values are given at a one month delay on the FAA official webpage, which makes it difficult to obtain real-time information on the aviation route dose. In order to overcome this critical limitation regarding the time delay for space weather customers, we developed a HCP prediction model based on sunspot number variations (Hwang et al. 2015). In this paper, we focus on improvements to our HCP prediction model and update it with neutron monitoring data. We found that the most accurate method to derive the HCP value involves (1) real-time daily sunspot assessments, (2) predictions of the daily HCP by our prediction algorithm, and (3) calculations of the resultant daily effective dose rate. Additionally, we also derived the HCP prediction algorithm in this paper by using ground neutron counts. With the compensation stemming from the use of ground neutron count data, the newly developed HCP prediction model was improved.

Antimicrobial resistance rates changes according to the amount of the antimicrobial agent in clinically important strain isolated from blood cultures (혈액배양에서 분리된 임상적 주요 균주의 항균제사용량에 따른 내성률 변화)

  • Kim, Jae-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.653-659
    • /
    • 2016
  • The purpose of the study is to investigate the correlation between the amount of antimicrobial agent (Defined Daily Dose, DDD) and antimicrobial resistance rate (%). The treatment of infectious diseases is becoming increasingly difficult, due to the increase in the number of multi-drug resistant bacteria, making it a clinically significant problem. Among the various factors, antimicrobial abuse is a major cause of antimicrobial resistance. The study was conducted on inpatients in a secondary university hospital in the central region utilizing the hospital's computerized statistical data and microbiological program of laboratory medicine from January 2010 to December 2014 pertaining to the dose of antimicrobial drugs for Acinetobacter baumannii, Pseudomonas aeruginosa, Klebsiella pneumoniae, and Escherichia coli strains isolated from blood culture. We analyzed the antimicrobial resistance rate per dose with the Pearson correlation coefficient. A significant (positive?) correlation was detected between the cefepime dose and the resistance of E. coli (P<0.033; r=0.907), while a significant negative correlation was found between the tobramycin dose and the resistance of E.coli. (P<0.028; r=-0.917). The aminoglycoside resistance of A. baumannii showed a significant negative correlation (P<0.048; r=-0.881), and the aminoglycoside resistance of E. coli showed a significant negative correlation as well (P<0.001; r=-0.992). In conclusion, the amount of antimicrobial agent (Defined Daily Dose, DDD) (is partly related to) the bacterial strain and its antimicrobial resistance rate (%).

Study on the Dose Characteristics of the PTW-LinaCheck Dosimeter and Its Application to Daily Output Measurement (PTW-LinaCheck 측정기의 선량 특성과 일일 출력측정 응용에 관한 연구)

  • Jeong, Dong-Hyeok;Lee, Kang-Kyoo;Moon, Un-Chul;Kim, Hyun-Jin;Kim, Young-Seok;Moon, Sun-Rock
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.56-62
    • /
    • 2008
  • In this study, we have investigated the dose characteristics of PTW-LinaCheck designed to detect output of medical LINAC and discussed clinical use of the detector. The reproducibility, linearity, and dose rate dependency of the dosimeter were measured for photons of 6 and 15MV and the electrons of 4, 6, 9, 12, and 16MeV. To know the error ranges of the measured data in daily output measurement, the response variations due to geometrical setup errors were measured. As a result of measurement, the error range from the geometrical setup and the reproducibility was less than ${\pm}0.6%$ for given beam qualities in daily output measurement, where the errors from the linearity and the dose rate dependency were negligible. Finally, we concluded that the LinaCheck dosimeter has a good characteristics in terms of dose and setup convenience in daily output measurement. In addition we have shown an examples of clinical use of this dosimeter for measuring daily output more than 60 days.

  • PDF

A Cosideration on Physical Aspects in Teleradiotherapy Chart QA (원격방사선치료 기록부의 QA 에서 물리적 측면의 고찰)

  • 강위생;허순녕
    • Progress in Medical Physics
    • /
    • v.10 no.2
    • /
    • pp.95-101
    • /
    • 1999
  • The aims of this report are to classify the incorrect data of patients and the errors of dose and dose distribution observed in QA activities on teleradiotherapy chart, and to analyze their frequency. In our department, radiation physicists check several sheets of patient chart to reduce numeric errors before starting radiation therapy and at least once a week, which include history, port diagram, MU calculation or treatment planning summary and daily treatment sheet. The observed errors are classified as followings. 1) Identity of patient, 2) Omitted or unrecorded history sheet even though not including the item related to dose, 3) Omission of port diagram, or omitted or erroneous data, 4) Erroneous calculation of MU and point dose, and important causes, 5) Loss of summary sheet of treatment planning, and erroneous data of patient in the sheet, 6) Erroneous record of radiation therapy, and errors of daily dose, port setup, MU and accumulated dose in the daily treatment sheet, 7) Errors leading inexact dose or dose distribution, errors not administerd even though its possibility, and simply recorded errors, 8) Omission of sign. Number of errors was counted rather than the number of patients. In radiotherapy chart QA from Jun 17, 1996 to Jul 31, 1999, no error of patient identity had been observed. 431 Errors in 399 patient charts had been observed and there were 405 physical errors, 9 cases of omitted or unrecorded history sheet, and 17 unsigned. There were 23 cases (5.7%) of omitted port diagram, 21 cases (5.2%) of omitted data and 73 cases (18.0 %) of erroneous data in port diagram, 13 cases (3.2 %) treated without MU calculation, 68 cases (16.3 %) of erroneous MU, 8 cases (2.0%) of erroneous point dose, 1 case (0.2 %) of omitted treatment planning summary, 11 cases (2.7%) of erroneous input of patient data, 13 cases (3.2%) of uncorrected record of treatment, 20 cases (4.9%) of discordant daily doses in MU calculation sheet and daily treatment sheet, 33 cases (8.1%) of erroneous setup, 52 cases (12.8%) of MU setting error, 61 cases (15.1%) of erroneous accumulated dose. Cases of error leading inexact dose or dose distribution were 239 (59.0 %), cases of error not administered even though its possibility were 142 (35.1 %), and cases of simply recorded error were 24 (5.9 %). The numeric errors observed in radiotherapy chart ranged over various items. Because errors observed can actually contribute to erroneous dose or dose distribution, or have the possibility to lead such errors, thorough QA activity in physical aspects of radiotherapy charts is required.

  • PDF

Comparison of the Equivalent Dose of the Lens Part and the Effective Dose of the Chest in the PET/CT Radiation Workers in the Nuclear Medicine Department (핵의학과 PET/CT실 방사선작업종사자의 수정체 부위의 등가선량과 흉부의 유효선량의 측정 비교)

  • Son, Sang-Joon;Park, Jeong-Kyu;Jung, Dong-Kyung;Park, Myeong-Hwan
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.209-215
    • /
    • 2019
  • Comparison of the effective dose of the chest and the equivalent dose of the lens site in the radiation workers working at four medical institutions with the PET / CT room located in one metropolitan city and province from April 1 to June 30, 2018 Respectively. Radioactive medicine were measured at the time of dispensing and at the time of injection. In this experiment, the average dispensing time per patient was 5.7 minutes and the average injection time was 3.1 minutes. The equivalent dose at the lens site was $0.78{\mu}Sv/h$ for 1 mCi, and the effective dose for chest was $0.18{\mu}Sv/h$ per 1 mCi. The equivalent dose at the lens site during injection was $0.88{\mu}Sv/h$ per mCi and the effective dose of chest was $0.20{\mu}Sv/h$ per mCi. The daily effective dose of the chest was $0.9{\pm}0.6{\mu}Sv$ and the equivalent dose of the lens site was $3.6{\pm}1.4{\mu}Sv$ during daily dosing for 20 days. The effective dose of the chest during the day was $0.6{\pm}0.5{\mu}Sv$ and the equivalent dose of the lens was $2.2{\pm}1.0{\mu}Sv$. At the time of dispensing, the equivalent dose of the lens was $0.187{\pm}0.035mSv$, the effective dose of the chest was $0.137{\pm}0.055mSv$, the equivalent dose of the lens was $0.247{\pm}0.057mSv$, and the effective dose of the monthly chest was $0.187{\pm}0.021mSv$. As a result of the corresponding sample test, the equivalent dose and the effective dose of the chest, the effective dose of the chest, the effective dose of the chest, the effective dose of the chest, The equivalent dose of the lens and the effective dose of the chest were statistically significant (p<0.05) with a significance of 0.000. However, there was no statistically significant difference (p>0.05) between the equivalent dose and the effective dose of the chest, the equivalent dose of the lens at the time of injection, and the effective dose of the chest at 0.138 and 0.230, respectively.

Recommended Rice Intake Levels Based on Average Daily Dose and Urinary Excretion of Cadmium in a Cadmium-Contaminated Area of Northwestern Thailand

  • La-Up, Aroon;Wiwatanadate, Phongtape;Pruenglampoo, Sakda;Uthaikhup, Sureeporn
    • Toxicological Research
    • /
    • v.33 no.4
    • /
    • pp.291-297
    • /
    • 2017
  • This study was performed to investigate the dose-response relationship between average daily cadmium dose (ADCD) from rice and the occurrence of urinary cadmium (U-Cd) in individuals eating that rice. This was a retrospective cohort designed to compare populations from two areas with different levels of cadmium contamination. Five-hundred and sixty-seven participants aged 18 years or older were interviewed to estimate their rice intake, and were assessed for U-Cd. The sources of consumed rice were sampled for cadmium measurement, from which the ADCD was estimated. Binary logistic regression was used to examine the association between ADCD and U-Cd (cut-off point at $2{\mu}g/g$ creatinine), and a correlation between them was established. The lowest estimate was $ADCD=0.5{\mu}g/kg\;bw/day$ [odds ratio (OR) = 1.71; with a 95% confidence interval (CI) 1.02-2.87]. For comparison, the relationship in the contaminated area is expressed by $ADCD=0.7{\mu}g/kg\;bw/day$, OR = 1.84; [95 % CI, 1.06-3.19], while no relationship was found in the non-contaminated area, meaning that the highest level at which this relationship does not exist is $ADCD=0.6{\mu}g/kg\;bw/day$ [95% CI, 0.99-2.95]. Rice, as a main staple food, is the most likely source of dietary cadmium. Abstaining from or limiting rice consumption, therefore, will increase the likelihood of maintaining U-Cd within the normal range. As the recommended maximum ADCD is not to exceed $0.6{\mu}g/kg\;bw/day$, the consumption of rice grown in cadmium-contaminated areas should not be more than 246.8 g/day. However, the exclusion of many edible plants grown in the contaminated area from the analysis might result in an estimated ADCD that does not reflect the true level of cadmium exposure among local people.