• Title/Summary/Keyword: DSP(Digital Signal Processor) controller

Search Result 144, Processing Time 0.025 seconds

Real-Time Harmonic Parameters Analyzer for Evaluating Induction Motor Drive System (유도전동기 구동시스템 평가를 위한 실시간 고조피 파라미터 분석장치)

  • Lim, Young-Cheol;Jung, Young-Gook
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.479-483
    • /
    • 1997
  • In general, motor parameters can be divided into mechanical/electrical parameters and harmonic parameters. Mechanical/electrical parameters identification of motor have been studying systematically for a long time. But, systematical study on harmonic parameters analysis for efficient motor drive system are very poor. The goal of this paper is to propose analyzing method of harmonic parameters for motor drive system with various experimental graphic screens and numerical results and to develope harmonic parameters analyzer. A developed analyzer is made up 586-PC and DSP (digital signal processor) board, motor drive system, power and harmonic parameters analyzing software for windows. Harmonic parameters are analyzed using correlation signal processing techniques based on the correlation between voltage and current waveforms. Analysis results are visualized by 3-D current coordinates, and it is compared and evaluated with conventional time/frequency domain. To verify the validity of the proposed system, 1/4HP capacitor run type single phase induction motor and thyristor speed controller is used for analyzing. Harmonic parameters of motor drive system is analyzed and verified, with varying fire angle of thyristor speed controller, and the proposed approach is to confirm validity.

  • PDF

Development of the Natural Frequency Analysis System to Examine the Defects of Metal Parts (금속 부품의 결함 판단을 위한 고유 주파수 분석 시스템 개발)

  • Lee, Chung Suk;Kim, Jin Young;Kang, Joonhee
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.169-174
    • /
    • 2015
  • In this study, we developed a system to detect the various defects in the metallic objects using the phenomenon that the defects cause the changes of the natural resonant frequencies. Our system consists of a FFT Amp, an Auto Impact Hammer, a Hammer controller and a PC. Auto Impact Hammer creates vibrations in the metallic objects when tapped on the surface. These vibrational signals are converted to the voltage signals by an acceleration sensor attached to the metallic part surface. These analog voltage signals were fed into an ADC (analog-digital converter) and an FFT (fast fourier transform) conversion in the FFT Amp to obtain the digital data in the frequency domain. Labview graphical program was used to process the digital data from th FFT amp to display the spectrum. We compared those spectra with the standard spectrum to find the shifts in the resonant frequencies of the metal parts, and thus detecting the defects. We used PCB's acceleration sensor and TI's TMS320F28335 DSP (digital signal processor) to obtain the resolution of 2.93 Hz and to analyze the frequencies up to 44 kHz.

An Active Damping Device for a Distributed Power System (전력시스템을 위한 Active Damping Device)

  • La, Jae-Du
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.116-121
    • /
    • 2009
  • Distributed power systems (DPSs) has been widely used various industrial/military applications due to their various advantages. Furthermore, the "All electric" concept, in conjunction with DC DPS, appears to be more advanced and mature in the AEV(All-Electric Vehicular) industry. Generally, AEV carry many loads with varied functions. However, there may be large pulsed loads with short duty ratios which can affect the normal operation of other loads. In this paper, a converter with spilt capacitors and a simple adaptive controller is proposed as a active damping device to mitigate the voltage transients on the bus. The proposed converter allows the smaller capacitive storage. In addition, the proposed control approach has the advantage of requiring only one sensor and performing both the functions of mitigating the voltage bus transients and maintaining the level of energy stored. The control algorithm has been implemented on a TMS320F2812 Digital Signal Processor (DSP). Simulation and experimental results are presented which verify the proposed control principle and demonstrate the practicality of the circuit topology.

Numerical Analysis of a Flux-Reversal Machine with 4-Switch Converters

  • Lee, Byoung-Kuk;Kim, Tae-Heoung
    • Journal of Magnetics
    • /
    • v.17 no.2
    • /
    • pp.124-128
    • /
    • 2012
  • Many different converter topologies have been developed with a view to use the minimum number of switches in order to reduce construction costs. Among this research, the four-switch converter topology with a novel PWM control technique based on the current controlled PWM method is thought to be a good solution. In this paper, a two dimensional time-stepped voltage source finite-element method (FEM) is used to analyze the characteristics of a Flux-Reversal Machine (FRM) with a 4-switch converter. To validate the proposed computational method, a digital signal processor (DSP) installed controller and prototype FRM are built and experiments performed.

A study on a multi-input time control of multi-joint manipulator using sliding mode (슬라이딩 모드를 이용한 다관절 매니퓰레이터의 다입력 실시간 제어에 관한 연구)

  • 이민철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.652-657
    • /
    • 1992
  • This paper presents to accomplish successfully a multi-input real time control by applying control hierarchy for sliding mode of multi-joint manipulators whose nonlinear terms are regarded as disturbances. We- could simplify the dynamic equations of a manipulator and servo system, which are composed of linear elements and nonlinear elements, by assuming that nonlinear terms, which are Inertia term, gravity force term, Coriolis force term and centrifugal force term, are external disturbance. By simplifying that equation, we could easily obtain a control input which satisfy sliding mode of multi-input system. We proposed a new control input algorithm in order to decrease chattering by changing control input according as effect of disturbance if a control response become within allowance error range. In this experiments, we used DSP(Digital Signal Processor) controller to suppress chattering by time delay of calculation and to carry out real time control.

  • PDF

Design and Performance Test of Controller of Interlinking Converter in AC/DC Microgrid in Hardware-in-the-Loop Simulation Environment (HILS 환경에서 AC/DC 마이크로그리드의 연계 컨버터 제어기 설계 및 테스트)

  • Ji, Hyeon-Kyun;Yoo, Hyeong-Jun;Kim, Hak-Man;Lee, Byeong-Ha
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.527-528
    • /
    • 2015
  • 최근 다양한 디지털기기에 따른 DC 부하의 증가와 함께 기존 배전망과 연계하여 운용할 수 있는 AC 그리드와 태양광과 연료전지 같은 DC 전원에 직접적으로 연계하여 운용하는 DC 그리드를 통합하는 AC/DC 마이크로그리드에 대한 연구가 진행되고 있다. 본 논문에서는 AC 그리드와 DC 그리드를 연계 제어하는 연계(interlinking) 컨버터의 제어기를 설계하고 성능을 검토하기 위해 TMS320F28335 DSP(Digital Signal Processor)와 실시간 디지털 시뮬레이터인 eMEGAsim으로 구성된 HILS(Hardware-in-the-Loop Simulation) 시스템을 구축하고 설계된 제어기의 성능을 테스트하였다.

  • PDF

Design of a Fuzzy-Sliding Mode Controller for a SCARA Robot to Reduce Chattering

  • Go, Seok-Jo;Lee, Min-Cheol
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.339-350
    • /
    • 2001
  • To overcome problems in tracking error related to the unmodeled dynamics in the high speed operation of industrial robots, many researchers have used sliding mode control, which is robust against parameter variations and payload changes. However, these algorithms cannot reduce the inherent chattering which is caused by excessive switching inputs around the sliding surface. This study proposes a fuzzy-sliding mode control algorithm to reduce the chattering of the sliding mode control by fuzzy rules within a pre-determined dead zone. Trajectory tracking simulations and experiments show that chattering can be reduced prominently by the fuzzy-sliding mode control algorithm compared to a sliding mode control with two dead zones, and the proposed control algorithm is robust to changes in payload. The proposed control algorithm is implemented to the SCARA (selected compliance articulated robot assembly) robot using a DSP (digital signal processor) for high speed calculations.

  • PDF

Implementation of a Fast Current Controller using FPGA (FPGA를 이용한 고속 전류 제어기의 구현)

  • Jung, Eun-Soo;Lee, Hak-Jun;Sul, Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.223-225
    • /
    • 2007
  • 본 논문에서는 FPGA(Field Programmable Gate Array) 기반의 전류 제어기를 설계하고 구현하였다. 기존의 DSP (Digital Signal Processor) 기반의 전류 제어기는 알고리즘 연산으로 인해 일반적으로 한 샘플링의 디지털 시지연이 발생한다. 반면에, FPGA 기반의 전류제어기는 FPGA의 높은 연산 능력을 이용하여, 알고리즘 연산에 필요한 시간을 감소시킬 수 있다. 이는 시지연이 물리적으로 줄기 때문에, 어떠한 시지연 보상 알고리즘 없이 전류 제어기의 대역폭을 향상시킬 수 있다. 구현된 FPGA 기반의 전류 제어기의 성능은 실험을 통해 검증되었다.

  • PDF

Controller Design and Experiment to Levitate a Rotor in an Active Magnetic Bearing System (능동 자기 베어링 시스템의 제어기 설계 및 연구)

  • Chang, Yu;Shim, Sung-Hyo;Yang, Joo-Ho
    • Journal of Power System Engineering
    • /
    • v.6 no.4
    • /
    • pp.73-80
    • /
    • 2002
  • 이 논문은 MIMO 능동 자기 베어링 시스템에 있어서의 병진 및 회전(기울기)운동을 하는 횡축형 강체 로터의 동적 거동을 모델링하고, 로터 양 끝단의 간섭효과를 고려한 제어방법을 제안한다. 제어기는 DSP 보드를 이용하였으며, 설계된 제어기의 타당성을 시뮬레이션 및 실험을 통하여 검증하였다.

  • PDF

Fast Response and Versatility in Digitally Controlled Rolling Mill DC Drives (고성능, 다기능의 Rolling Mill DC전동기 제어 시스템 개발)

  • Kim, K.H.;Cho, W.J.;Park, I.Y.;Song, S.H.;Park, K.W.;Choi, C.H.;Sul, S.K.;Ji, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.595-602
    • /
    • 1994
  • PERISTOR-3000 loaded with 32 bit DSP(Digital Signal Processor) is a technically advanced versatile dc motor controller in applications with very high requirements for rapid response, control accuracy and reliability. The current controller of PERISTOR-3000 is of the predictive type and gives fast control with both discontinuous and continuous current compared to the conventional PI current control. The speed controller gain is compensated to improve response behavior. PERISTOR-3000 communicates with its host computer, POSTAR-3200, or any IBM or compatible PC and can be controlled. Dedicated monitoring system for MMI is introduced.

  • PDF