복부일반촬영시 선원과 검출기간의 거리변화에 따른 영상 화질 및 피폭선량에 관한 연구 (A Study on Patients Dose and Image Quality according to Source to Image receptor Distance in Abdomen Radiography: comparison of ESD measured and DRLs in other countries)

  • 장지성;최원근;정재연;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.39-46
    • /
    • 2012
  • Purpose : The purpose of this study was to reduce Entrance Surface Dose and maintain image quality by changing Source to Image receptor Distance. And we'd like to compare ESD on this study to DRLs in other contries. Materials and Methods : We used indirect DR system(Definium 8000, General Electric, USA)and phantom(ART-200X, Flukebiomedical, USA),glass dosimeters(GD-352M, Asahi Techno Glass, Japan)for this study. The imagies were obtained throuh 80kVp fixed, and different tube currents using AEC mode in $16{\times}16$(inch) field size and changing Source to Image receptor Distance from 100 cm to 130 cm per 10 cm unit. The phantom with attaching 5 glass dosimeters on abdomonal skin was set at supine and erect position as a anterioposterial projection on detector For measuring Entrance Surface Dose. Image analysis was conducted by histograms of Image J(1.46r) which was given from National Institutes of Health(NIH). Results : Due to inverse square law of distance, the tube currents were increasing 42.6 % in supine position and 32.6 % in erect position according to the change of Source to Image receptor Distance. While Entrance Surface Doses were rapidly decreasing 14.2 % in supine position and 29.4 % in erect position according to the change of Source to Image receptor Distance. As the results of histogram using Image J, pixel mean values from 100 cm to 110 cm, 120 cm and 130 cm were decreasing each 1.4%, 2.5%, 2.7%, 4.5%, 2.2 %, 5.8 % in supine, erect position. While standard deviations from 100 cm to 110 cm, 120 cm and 130 cm were increasing each 1.4 %, 2.5 %, 2.5 %, 4.0 %, 2.0 %, 4.9 % Consequently, there are no significant differences in abdomen images taken. Conclusion: As the results described above, we strongly recommend using long Sourceto Image receptor Distance than 100cm that we have been using. So, we should deliver less Entrance Surface Dose to the patients while maintaining image quality in abdomen radiography.

  • PDF

나노크기 TiO2의 제조에 미치는 첨가제 영향 (The Effect of Additives on the Preparation of Nanosized TiO2 Particles)

  • 김석현;나석은;김시영;김성수;주창식
    • Korean Chemical Engineering Research
    • /
    • 제51권4호
    • /
    • pp.426-431
    • /
    • 2013
  • 비교적 낮은 온도와 상압에서 전구체 Titanium(IV) sulfate와 염기성 용액을 반응시키는 수열합성법을 이용하여 소성과정을 거치지 않고 $TiO_2$ 나노입자를 제조하였다. 염기성 용액의 종류(NaOH, $NH_4OH$, Monoethanolamine, Diethanolamine, Triethanolamine), 첨가되는 계면활성제의 종류(CTAB, Span 20, SDBS)와 농도, 제조 온도, pH 등을 변화시켜 $TiO_2$를 제조하였고, 생성되는 입자의 결정성, 입자크기 등과 같은 물리적 특성은 XRD, SEM, Zeta-potential 등을 사용하여 분석하였다. 또한, 광촉매적 특성을 확인하기 위하여 DRS를 통해 흡광면적을 측정, 비교하였다. 침전제로 사용된 염기성 물질 중 NaOH가 결정성이 우수하고 입자크기가 작은 $TiO_2$를 제조하는데 가장 효과적임을 확인할 수 있었다. 계면활성제는 양이온성 계면활성제인 CTAB를 첨가한 경우 다른 계면활성제보다 작은 크기의 $TiO_2$를 제조할 수 있었다. 그리고 동일한 조건에서 전구체인 $Ti(SO_4)_2$와 CTAB의 농도비를 10 : 1로 조절한 경우 CTAB를 첨가하지 않은 경우보다 제조되는 $TiO_2$ 입자의 크기는 약 1/10인 5.8 nm로 감소하였다.

Al-Si-Cu 알루미늄 주조 합금의 열간 균열 민감성에 미치는 Cu 함량의 영향 (Effect of Cu content on Hot Tearing Susceptibility in Al-Si-Cu Aluminum Casting Alloy)

  • 오승환;친밧 문크대거;김헌주
    • 한국주조공학회지
    • /
    • 제41권5호
    • /
    • pp.419-433
    • /
    • 2021
  • Al-Si-Cu 합금은 구리 첨가에 따른 석출경화로 경도와 강도가 현저하게 강한 합금을 생성하는 장점이 있습니다. 그러나 구리를 첨가하면 Al-Si-Cu 합금의 응고 범위가 확장되고 합금은 응고 중에 발생하는 가장 흔하고 심각한 파단 현상 중 하나 열간 균열이 발생하기 쉽습니다. 합금의 열간 균열 특성에 대한 기존의 평가 방법은 이 특성에 대한 정량적 데이터를 제공하지 않는 상대적이고 정성적인 분석 방법입니다. 이 연구에서 Al-Si-Cu 주조 합금의 열간 균열 특성에 대한 더 신뢰할 수있는 정량 데이터를 얻기 위해 Instone et. al 이 개발 한 장치를 부분적으로 수정되었습니다. Cu 원소의 영향을 평가하기 위해 Al-Si-Cu 계 합금에서 4 가지 수준의 Cu 함량을 (0.5, 1.0, 3.0, 5.0) wt. %로 설정하고 각 합금에 대해 열간 균열 특성을 평가했습니다. Cu 함량이 증가함에 따라 열간 균열 강도는 (2.26, 1.53, 1.18, 1.04) MPa)로 감소했습니다. 열간 균열이 발생하는 시점, Cu 함량이 증가함에 따라 고액 공존 범위가 증가하여 동일 온도에서 해당 고상율 및 응고 속도가 감소하였다. 파단면의 형태는 수상 돌기에서 잔류 액상으로 덮인 수상 돌기로 바뀌었고, 열간 균열 발생 인근에서 CuAl2 상이 관찰되었다.

Glial Cell Line-Derived Neurotrophic Factor, S-100 Protein and Synaptophysin Expression in Biliary Atresia Gallbladder Tissue

  • Gurunluoglu, Semra;Ceran, Canan;Gurunluoglu, Kubilay;Kocbiyik, Alper;Gul, Mehmet;Yildiz, Turan;Bag, Harika Gozukara;Gul, Semir;Tasci, Aytac;Bayrakci, Ercan;Akpinar, Necmettin;Cin, Ecem Serbest;Ates, Hasan;Demircan, Mehmet
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제24권2호
    • /
    • pp.173-186
    • /
    • 2021
  • Purpose: Biliary atresia (BA) is a disease that manifests as jaundice after birth and leads to progressive destruction of the ductal system in the liver. The aim of this study was to investigate histopathological changes and immunohistochemically examine the expression of glial cell line-derived neurotrophic factor (GDNF), synaptophysin, and S-100 protein in the gallbladder of BA patients. Methods: The study included a BA group of 29 patients and a control group of 41 children with cholecystectomy. Gallbladder tissue removed during surgery was obtained and examined immunohistochemically and histopathologically. Tissue samples of both groups were immunohistochemically assessed in terms of GDNF, S-100 protein, and synaptophysin expression. Expression was classified as present or absent. Inflammatory activity assessment with hematoxylin and eosin staining and fibrosis assessment with Masson's trichrome staining were performed for tissue sample sections of both groups. Results: Ganglion cells were not present in gallbladder tissue samples of the BA group. Immunohistochemically, GDNF, synaptophysin, and S-100 expression was not detected in the BA group. Histopathological examination revealed more frequent fibrosis and slightly higher inflammatory activity in the BA than in the control group. Conclusion: We speculate that GDNF expression will no longer continue in this region, when the damage caused by inflammation of the extrahepatic bile ducts reaches a critical threshold. The study's findings may represent a missing link in the chain of events forming the etiology of BA and may be helpful in its diagnosis.

한국형 사과 병해충종합관리(IPM) 체계 수립을 위한 기초연구의 전개: 이순원 박사의 연구 사례 (Development of Basic Research for Establishing the Apple IPM System in Korea: Dr. Lee Soon-Won's Research Case)

  • 안정준;오현석;최경산;최경희;도윤수;이선영;이동혁
    • 한국응용곤충학회지
    • /
    • 제60권1호
    • /
    • pp.1-13
    • /
    • 2021
  • 1950년대에 종합적 유해생물관리(IPM)의 개념이 발달하기 시작하여 1960년대에는 경제학적 개념이 해충방제에 포함되기 시작하였다. 1970년대부터 미국과 유럽을 중심으로 종합방제와 관련된 연구가 진행되었다. 우리나라 병해충 종합방제에 관한 연구는 1970년대 감귤해충에 대한 종합방제연구와 통일계 품종의 보급에 따른 수도해충종합방제연구에서 시작되었다. 우리나라 사과 병해충종합관리 연구는 1980년대 화학농약을 이용한 방제 및 약제 저항성 연구, 해충 및 천적생태에 대한 연구, 성페로몬에 대한 연구를 시작으로 진행되었다. 1990년대부터는 농가보급을 위한 IPM 연구사업과 현장실증사업이 병행되었다. 2000년대에는 교미교란제를 중심으로 한 해충예찰과 발생모형 개발, 해충에 대한 DB프로그램 및 정보공유를 위한 네트워크가 구축되었다. 2010년대는 무인예찰 및 자동화기술 개발을 통해 IPM 기술이 확장되고 있다.

Why A Multimedia Approach to English Education\ulcorner

  • Keem, Sung-uk
    • 대한음성학회:학술대회논문집
    • /
    • 대한음성학회 1997년도 7월 학술대회지
    • /
    • pp.176-178
    • /
    • 1997
  • To make a long story short I made up my mind to experiment with a multimedia approach to my classroom presentations two years ago because my ways of giving instructions bored the pants off me as well as my students. My favorite ways used to be sometimes referred to as classical or traditional ones, heavily dependent on the three elements: teacher's mouth, books, and chalk. Some call it the 'MBC method'. To top it off, I tried audio-visuals such as tape recorders, cassette players, VTR, pictures, and you name it, that could help improve my teaching method. And yet I have been unhappy about the results by a trial and error approach. I was determined to look for a better way that would ensure my satisfaction in the first place. What really turned me on was a multimedia CD ROM title, ELLIS (English Language Learning Instructional Systems) developed by Dr. Frank Otto. This is an integrated system of learning English based on advanced computer technology. Inspired by the utility and potential of such a multimedia system for regular classroom or lab instructions, I designed a simple but practical multimedia language learning laboratory in 1994 for the first time in Korea(perhaps for the first time in the world). It was high time that the conventional type of language laboratory(audio-passive) at Hahnnam be replaced because of wear and tear. Prior to this development, in 1991, I put a first CALL(Computer Assisted Language Learning) laboratory equipped with 35 personal computers(286), where students were encouraged to practise English typing, word processing and study English grammar, English vocabulary, and English composition. The first multimedia language learning laboratory was composed of 1) a multimedia personal computer(486DX2 then, now 586), 2) VGA multipliers that enable simultaneous viewing of the screen at control of the instructor, 3) an amplifIer, 4) loud speakers, 5)student monitors, 6) student tables to seat three students(a monitor for two students is more realistic, though), 7) student chairs, 8) an instructor table, and 9) cables. It was augmented later with an Internet hookup. The beauty of this type of multimedia language learning laboratory is the economy of furnishing and maintaining it. There is no need of darkening the facilities, which is a must when an LCD/beam projector is preferred in the laboratory. It is headset free, which proved to make students exasperated when worn more than- twenty minutes. In the previous semester I taught three different subjects: Freshman English Lab, English Phonetics, and Listening Comprehension Intermediate. I used CD ROM titles like ELLIS, Master Pronunciation, English Tripple Play Plus, English Arcade, Living Books, Q-Steps, English Discoveries, Compton's Encyclopedia. On the other hand, I managed to put all teaching materials into PowerPoint, where letters, photo, graphic, animation, audio, and video files are orderly stored in terms of slides. It takes time for me to prepare my teaching materials via PowerPoint, but it is a wonderful tool for the sake of presentations. And it is worth trying as long as I can entertain my students in such a way. Once everything is put into the computer, I feel relaxed and a bit excited watching my students enjoy my presentations. It appears to be great fun for students because they have never experienced this type of instruction. This is how I freed myself from having to manipulate a cassette tape player, VTR, and write on the board. The student monitors in front of them seem to help them concentrate on what they see, combined with what they hear. All I have to do is to simply click a mouse to give presentations and explanations, when necessary. I use a remote mouse, which prevents me from sitting at the instructor table. Instead, I can walk around in the room and enjoy freer interactions with students. Using this instrument, I can also have my students participate in the presentation. In particular, I invite my students to manipulate the computer using the remote mouse from the student's seat not from the instructor's seat. Every student appears to be fascinated with my multimedia approach to English teaching because of its unique nature as a new teaching tool as we face the 21st century. They all agree that the multimedia way is an interesting and fascinating way of learning to satisfy their needs. Above all, it helps lighten their drudgery in the classroom. They feel other subjects taught by other teachers should be treated in the same fashion. A multimedia approach to education is impossible without the advent of hi-tech computers, of which multi functions are integrated into a unified system, i.e., a personal computer. If you have computer-phobia, make quick friends with it; the sooner, the better. It can be a wonderful assistant to you. It is the Internet that I pay close attention to in conjunction with the multimedia approach to English education. Via e-mail system, I encourage my students to write to me in English. I encourage them to enjoy chatting with people all over the world. I also encourage them to visit the sites where they offer study courses in English conversation, vocabulary, idiomatic expressions, reading, and writing. I help them search any subject they want to via World Wide Web. Some day in the near future it will be the hub of learning for everybody. It will eventually free students from books, teachers, libraries, classrooms, and boredom. I will keep exploring better ways to give satisfying instructions to my students who deserve my entertainment.

  • PDF

전산화 방사선촬영(CR) 시스템을 이용한 근사적 의료 피폭 선량 평가 (Evaluation of Approximate Exposure to Low-dose Ionizing Radiation from Medical Images using a Computed Radiography (CR) System)

  • 우민선;이재승;임인철
    • 한국방사선학회논문지
    • /
    • 제6권6호
    • /
    • pp.455-464
    • /
    • 2012
  • 본 연구는 일반 X선 검사에서 CR 시스템을 이용한 환자의 근사적 피폭 선량을 평가할 수 있는 실험적 모델을 제시하고 저선량 영역에서 의료 피폭에 대한 방어의 최적화 조건으로 환자의 선량 권고량(diagnostic reference level. DRL)을 비교하고자 하였다. 이를 위하여 기준선량계와 광자극발광선량계(optically stimulated luminescence dosimeters. OSLDs)를 이용하여 관전압(kVp) 및 관전류 노출시간의 곱(mAs)에 따른 입사표면선량(entrance surface dose. ESD)을 교차 측정하였으며 CR 시스템에서 각 노출 조건에 대한 Hounsfield unit (HU) scale을 측정하여 ESD와 HU 스케일에 대한 특성 관계를 이용하여 근사적 피폭 선량을 구하였다. 또한 임상적으로 적용 가능한지를 알기 위하여 두부, 경부, 흉부, 복부, 골반부 노출 조건으로 물 팬텀에 모사하여 피폭 선량을 구하였다. 결과적으로 두 선량계의 평균 ESD는 각각 2.10, 2.01, 1.13, 2.97, 1.95 mGy 이었으며 CR 영상에서 측정한 HU 스케일은 각각 $3,276{\pm}3.72$, $3,217{\pm}2.93$, $2,768{\pm}3.13$, $3,782{\pm}5.19$, $2,318{\pm}4.64$ 이었다. 이 때 ESD와 HU 스케일에 대한 특성 관계를 이용하여 근사적으로 구한 ESD는 각각 2.16, 2.06, 1.19, 3.05, 2.07 mGy이었으며 평균 측정값과 근사적으로 구한 ESD의 오차는 3% 미만으로 영상의학 분야의 측정 오차 5%를 감안한다면 신뢰할 수 있는 오차 범위라 할 수 있었다. 결론적으로 CR 시스템을 이용한 일반 X선 검사에서 환자의 피폭 선량을 근사적으로 평가할 수 있는 새로운 실험적 모델을 제시하였으며 CR 검사뿐 만 아니라 디지털 방사선촬영(digital radiography. DR) 시스템 및 필름-증감지 시스템에 적용 가능할 것으로 판단되었다.

프로토타입 R/F 흉부 디지털 단층영상합성장치 시스템에서 잘림 아티팩트 감소를 위한 가중 정규화 접근법에 대한 연구 (Truncation Artifact Reduction Using Weighted Normalization Method in Prototype R/F Chest Digital Tomosynthesis (CDT) System)

  • 손준영;최성훈;이동훈;김희중
    • 한국방사선학회논문지
    • /
    • 제13권1호
    • /
    • pp.111-118
    • /
    • 2019
  • 흉부 디지털 단층영상합성장치는 기존 DR의 낮은 깊이 해상도, CT의 높은 피폭선량 문제를 해결할 수 있는 획기적인 영상장치로 대두되고 있다. 그러나 제한된 스캔 각도로 인해 프로젝션이 X 선 소스 동작 방향으로 흉부를 완전히 포함 할 수 없어 재구성 된 슬라이스의 위, 아래 방향 경계를 따라 강도의 불연속성이 발생하게 되는데 이러한 현상을 잘림 아티팩트 (Truncation artifact)라고 한다. 이 연구의 목적은 가중 정규화 접근법을 사용하여 잘림 아티팩트를 줄이고 리스템에서 개발한 프로토 타입 흉부 디지털 단층영상합성장치 시스템에 대한 이 접근법의 성능을 평가하는 것이다. 이 시스템의 source-to-image distance는 1100 mm 이고 X 선원의 회전 중심은 검출기 표면에서 100mm 위로 설정되었다. LUNGMAN 팬텀을 사용하여 ${\pm}20^{\circ}$의 투영 뷰를 $1^{\circ}$ 간격으로 41장을 얻은 후, filtered back projection 알고리즘으로 재구성했다. 정량적 평가를 위하여 시뮬레이션을 이용하여 기준영상을 재구성 후 peak signal to noise ratio와 structure similarity index 값을 평가하였으며 실제 실험 데이터를 이용하여 mean value of specific direction 값을 평가하였다. 시뮬레이션 결과로 아티팩트 보정 전 일반적인 filtered back projection 알고리즘으로 재구성 한 영상과 비교하여 peak signal to noise ratio값과 structure similarity index값 모두 각각 증가하였으며, 실제 실험 재구성 영상의 mean value of specific direction 결과는 아티팩트의 영향이 감소됨을 확인할 수 있었다. 결론적으로, 가중 정규화 방법은 잘림 아티팩트를 줄임으로써 진단의 어려움을 발생시키는 가능성을 개선시킬 수 있는 방법으로 사료된다.

적외선열화상장치를 이용한 Buchanan plugger 표면의 온도상승 분석 (INFRARED THERMOGRAPHIC ANALYSIS OF TEMPERATURE RISE ON THE SURFACE OF BUCHANAN PLUGGER)

  • 최성아;김선호;황윤찬;윤창;오병주;최보영;정우남;정선와;황인남;오원남
    • Restorative Dentistry and Endodontics
    • /
    • 제27권4호
    • /
    • pp.370-381
    • /
    • 2002
  • This study was performed to evaluate the temperature rise on various position of the Buchanan plugger, the peak temperature of plugger's type and the temperature change by its touching time of heat control spling. The heat carrier system 'System B' (Model 1005, Analytic Technologies, USA) and the Buchanan's plug-gers of F, FM, M and ML sizes are used for this study. The temperature was set to 20$0^{\circ}C$ which Dr. Buchanan's "continuous wave of condensation" technique recommended on digital display and the power level on it was set to 10. In order to apply heat on the Buchanan's pluggers, the heat control spring was touched for 1, 2, 3, 4 and 5 seconds respectively. The temperature rise on the surface of the pluggers were measured at 0.5 mm intervals from tip to 20 mm length of shank using the infrared thermography (Radiation Thermometer-IR Temper, NEC San-ei Instruments, Ltd, Japan) and TH31-702 Data capture software program (NEC San-ei Instruments, Ltd, Japan). Data were analyzed using a one way ANOVA followed by Duncan's multiple range test and linear regression test. The results as follows. 1. The position at which temperature peaked was approximately at 0.5 mm to 1.5 mm far from the tip of Buchanan's pluggers (p<0.001). The temperature was constantly decreased toward the shank from the tip of it (p<0.001). 2. When the pluggerss were heated over 5 seconds, the peak temperature by time of measurement revealed from 253.3$\pm$10.5$^{\circ}C$ to 192.1$\pm$3.3$^{\circ}C$ in a touch for 1 sec, from 218.6$\pm$5.$0^{\circ}C$ to 179.5$\pm$4.2$^{\circ}C$ in a touch for 2 sec, from 197.5$\pm$3.$0^{\circ}C$ to 167.5$\pm$3.7$^{\circ}C$ in a touch for 3 sec, from 183.7$\pm$2.5$^{\circ}C$ to 159.8$\pm$3.6$^{\circ}C$ in a touch for 4 sec and from 164.9$\pm$2.$0^{\circ}C$ to 158.4$\pm$1.8$^{\circ}C$ in a touch for 5 sec. A touch for 1 sec showed the highest peak temperature, followed by, in descending order, 2 sec, 3 sec, 4 sec. A touch for 5 sec showed the lowest peak temperature (p<0.001). 3. A each type of pluggers showed different peak temperatures. The peak temperature was the highest in F type and followed by, in descending order, M type, ML type. FM type revealed the lowest peak temperature (p<0.001). The results of this study indicated that pluggers are designed to concentrate heat at around its tip, its actual temperature does not correlate well with the temperature which Buchanan's "continuous wave of condensation" technique recommend, and finally a quick touch of heat control spring for 1sec reveals the highest temperature rise.

평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구 (Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance)

  • 박지군;최장용;강상식;이동길;석대우;남상희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제26권4호
    • /
    • pp.39-46
    • /
    • 2003
  • 의료영상 분야에서의 디지털화가 시도되면서부터 평판형 디지털 영상검출기가 일반촬영 및 투시영상을 비롯한 다양한 영상 획득 장치에의 적용을 위해 꾸준히 연구, 개발되어져 왔다. 본 연구는 비정질 셀레늄을 이용한 디지털 방사선 검출기를 통해 획득된 영상의 평가를 통해 순수 국내 기술로 개발중인 디지털 방사선 검출기의 임상 사용여부를 확인하고, 영상평가의 주요인자인 modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) 이용하여 정량적인 값을 도출함으로써 의료영상평가에 필요한 측정 방법 및 그 기초 자료의 제공을 그 목적으로 한다. 비정질 셀레늄을 이용한 디지털 방사선 검출기는 pixel pitch가 $139\;{\mu}m$이며, 전체 active area은 $14{\times}8.5\;inch^2$, 전체 pixel의 수는 3.9백만개이다. 디지털 X-선 검출기에서 광도전체로서 비정질 셀레늄은 TFT 평판 패널 위에 진공 증착된다. 비정질 셀레늄의 두께는 $500\;{\mu}m$이다. 디지털 방사선 검출기의 성능을 평가하기 위해 민감도, 선형성, MTF, NPS, 그리고 DQE가 측정되었다. 선형성 평가에서는 뛰어난 선형성[($r^2$)=0.9693]을 보였다. 측정된 민감도는 인가전압 $10\;V/{\mu}m$에서 $4.16{\times}10^6\;ehp/pixel{\cdot}mR$이며, MTF는 2.5\;lp/mm에서 52%이다. 그리고 DQE는 1.5\;lp/mm에서 75%이다. 본 연구를 통해 영상평가 측정 기술의 기본적 토대를 마련하고, 측정된 값은 국내 기술로 개발중인 비정질 셀레늄을 이용한 직접방식의 디지털 방사선 검출기의 임상적 사용가치가 충분함을 뒷받침할 수 있는 기초 자료로서 제공될 수 있을 것으로 판단된다.

  • PDF