• Title/Summary/Keyword: DCPD

Search Result 96, Processing Time 0.037 seconds

Interfacial Evaluation and Microfailure Sensing of Nanocomposites by Electrical Resistance Measurements and Wettability (전기저항측정법 및 젖음성을 이용한 나노복합재료의 미세파손 감지능 및 계면물성 평가)

  • Park, Joung-Man;Kwon, Dong-Jun;Shin, Pyeong-Su;Kim, Jong-Hyun;Baek, Yeong-Min;Park, Ha-Seung
    • Composites Research
    • /
    • v.30 no.2
    • /
    • pp.138-144
    • /
    • 2017
  • Damage sensing of polymer composite films consisting of poly(dicyclopentadiene) p-DCPD and carbon nanotube (CNT) was studied experimentally. Only up to 1st ring-opening polymerization occurred with the addition of CNT, which made the modified film electrically conductive, while interfering with polymerization. The interfacial adhesion of composite films with varying CNT concentration was evaluated by measuring the wettability using the static contact angle method. 0.5 wt% CNT/p-DCPD was determined to be the optimal condition via electrical dispersion method and tensile test. Dynamic fatigue test was conducted to evaluate the durability of the films by measuring the change in electrical resistance. For the initial three cycles, the change in electrical resistance pattern was similar to the tensile stress-strain curve. The CNT/p-DCPD film was attached to an epoxy matrix to demonstrate its utilization as a sensor for fracture behavior. At the onset of epoxy fracture, electrical resistance showed a drastic increase, which indicated adhesive fracture between sensor and matrix. It leads to prediction of crack and fracture of matrix.

A Study on the Optimum Conditions for Preparation of Calcium hydrogenphosphate Dihydrate by Box-Wilson Experimental Design (Box-Wilson 실험계획에 의한 연마용 인산일수소칼슘의 최적 제조조건 추구 및 안정화)

  • Rhee, Gye-Ju;Kwak, Son-Hyuk;Suh, Sung-Su
    • Journal of Pharmaceutical Investigation
    • /
    • v.26 no.3
    • /
    • pp.221-232
    • /
    • 1996
  • An abrasive, calcium hydrogen phosphate dihydrate (DCPD), was synthesized in a Box-wilson experimental design by reactions between phosphoric acid and milk of lime, and calcium chloride and sodium phosphate solutions, and stabilized with TSPP and TMP. The optimum conditions for preparation of DCPD from phosphoric acid with milk of lime were such as; reaction temp.; $51.9^{\circ}C$, conc. of lime; 25.9%, conc. of phosphoric acd; 77.9%, drying temp.; $60.2^{\circ}C$ and final pH; 6.46. The physico-chemical and pharmaceutical properties of DCPD were showed as follows: glycerin absorption value(68 ml/100g), whiteness(99.5%), particle size(10.9 nm), pH(7.8), and set test(pass). XRD and SEM of DCPD indicated a monoclinic system crystallographically. $N_2$ adsorption isotherm curve by BET showed non porous type II form. The micromeritic parameters of DCPD showed that surface area was $3.27{\sim}4.6\;cm^{2}/g$ and pore volume, pore area and pore radius were negligible. The rheogram of the toothpaste containing DCPD showed pseudoplastic flow with yield value of 321, and thixotropic behavior forming hysteresis loop. These results meet the requirements as abrasive standard, and sythesized DCPD is expected as a good dental abrasive such as a high quality grade in practice.

  • PDF

A Study on the Polymerization of Dicyclopentadiene Production and Applied to Boats Materials (p-DCPD 제조 및 보트소재적용 연구)

  • Kim, Si-Young;Koo, Su-Jin;Ju, Chang-Sik;Park, Joo-Young
    • Journal of Power System Engineering
    • /
    • v.19 no.5
    • /
    • pp.86-92
    • /
    • 2015
  • p-DCPD were prepared by in-suit ROMP polymerization using $MoCl_5$ and $Et_2AlCl$. The results showed that $MoCl_5:Et_2AlCl:DCPD$ mole ratio of 1:2.0:350 had the curing-time of 60sec and crosslinking degree of 90.44%. The curing time of DCPD polymerization by $MoCl_5/Et_2AlCl$ was shortened, and monomer conversion and crosslinking degree were decreased with temperature and the number of moles of $MoCl_5$ and $Et_2AlCl$. $MoCl_5$ and $Et_2AlCl$ is damaged its function by the reaction with the air in the atmosphere and did't proceed the polymerization properly.

Effects of Particle Size Distribution of CaHPO4·2H2O on Self-hardening Bone Cement

  • Hwang, In-Soo;Cho, Sang-Hwan;Lee, Jong-Kyu
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.8
    • /
    • pp.730-734
    • /
    • 2003
  • This research examined the effect, which it follows in particle size distribution change of CaHPO$_4$ㆍ2$H_{2}O$ (DCPD). We used two kinds of compositions; tetracalcium phosphate (TTCP)/dicalcium phosphate dihydrate (DCPD) composition and $\alpha$-tricalcium phosphate ($\alpha$-TCP)TTCP/DCPD composition. As the result, the mean particle size of the DCPD decreased, the setting tine shortened at all compositions. The reference powder (DR), which did not milling, showed about 2 times strength value compared with other milling sample. Especially, the compressive strength of 60 : 20 : 20 sample (DR(do$_{0.5}$)=12.08 $\mu\textrm{m}$) after curing 7 days in simulated body fluid solution was 40$\pm$0.5 MPa, which was the highest. This resulted from the packing density at $\alpha$-TCP/TTCP/DCPD combination.

Bulk Coordination Polymerization of Dicyclopentadiene (DCPD) by Pd Complexes Containing β-Ketoiminate or β-Diketiminate Ligands

  • Lee, Eung Jun;Kim, Ho Sup;Lee, Byoung Ki;Hwang, Woon Sung;Sung, Ik Kyoung;Lee, Ik Mo
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.12
    • /
    • pp.4131-4136
    • /
    • 2012
  • Several palladium complexes containing ${\beta}$-ketoiminate and ${\beta}$-diketiminate ligands successfully produced poly(DCPD) possibly via vinyl addition. It was found that catalysts with ${\beta}$-diketiminate ligands containing bulkier aryl substituents showed the highest activity in the presence of MAO as a cocatalyst. Purity of DCPD is quite essential for the higher activity and small amount of organic solvent such as $CH_2Cl_2$ and toluene is required to reduce the viscosity of the reactant mixture for the higher activity. $^1H$ NMR spectra of produced polymers with N,N-dimethylanilinium tetra(pentafluorophenyl)borate (N,N-DAPFAr"$_4$) show that 5,6-double bond of DCPD is removed with 2,3-double bond remaining. Produced poly(DCPD) with MAO cocatalyst is quite rigid and insoluble in common organic solvents but rather brittle.

Selective Epoxidation of Di-cyclopentadiene Using Ti Containing Zeolite Catalyst (Ti 함유 제올라이트 촉매를 이용한 디시클로펜타디엔의 선택적 에폭시화 반응)

  • Lee, GiBbum;Ko, MoonKyu;Kim, YoungWun;Chung, KeunWo;Yoon, ByungTae;Kim, SeongBo
    • Applied Chemistry for Engineering
    • /
    • v.23 no.6
    • /
    • pp.614-617
    • /
    • 2012
  • Ti-containing zeolite was synthesised and used in the epoxidation of di-cyclopentadiene (DCPD). Among various Ti-zeolite catalysts, Y contained Ti-zeolite showed the highest yield in the epoxidation of DCPD. The study was also investigated in terms of the Ti content in the catalysts, $H_2O_2$/substrate ratio, reaction temperature and applied time. The reaction conditions significantly influenced on both the catalytic activity and selectivity. In addition, Ti structure in the zeolite was analyzed using IR and UV-vis spectroscopy.

The Change in Interfacial and Mechanical Properties for Glass Fiber/p-DCPD Composites with Degree of Ruthenium Catalyst Activation (루테늄촉매 활성정도에 따른 유리섬유/폴리다이사이클로펜타다이엔 복합재료의 기계 및 계면물성 변화)

  • Shin, Pyeong-Su;Kim, Jong-Hyun;Baek, Yeong-Min;Park, Ha-Seung;Kwon, Dong-Jun;Park, Joung-Man
    • Journal of Adhesion and Interface
    • /
    • v.19 no.1
    • /
    • pp.13-18
    • /
    • 2018
  • At ruthenium (Ru) catalyst was exposed from the atmosphere, the degree of catalyst activation decreased. The change of catalyst activity with the number of days of exposure to air for the Ru catalyst was confirmed using the surface tension method quantitatively. Mechanical properties and surfactant change after polymerization by DCPD using Ru catalyst for each air exposure day was evaluated. The Ru catalyst mixed with a dilution agent was exposed in the air and color was monitored for each day. Surface tension was measured using Wilhelmy and PTFE and associated with different catalyst activities. Heat was measured in real time during polymerizing DCPD with Ru catalyst. After polymerization, tensile strength was measured for p-DCPD and the change of material property was measured. Interfacial properties were also evaluated via microdroplet pull-out tests between glass fiber and p-DCPD. The surface tension was stable until the 4 days (33 dyne/cm) whereas the surface energy increased at the 10 days (34 dyne/cm), which could be correlated with oxidation of the catalyst. Tensile property and interfacial shear strength (IFSS) was also stable until the 4 days (tensile strength: 38 MPa and IFSS: 26 MPa) whereas the mechanical property decrease at 10 days (tensile strength: 15 MPa and IFSS: 3 MPa) dramatically.

A Study on the Measurement of the Crack Length Using the DCPD Method for the Fracture Test of the Pipe Specimen (직류전위차법을 이용한 배관 균열 길이 측정에 관한 연구)

  • Park, Jae-Sil;Seok, Chang-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.5
    • /
    • pp.640-647
    • /
    • 2004
  • In order to perform elastic-plastic fracture mechanical analyses, fracture resistance curves for concerned materials are required. The unloading compliance method and the DCPD(Direct Current Potential Drop) method have been widely used for measuring the crack length and the extension for a standard specimen fracture resistance curve test. However it is difficult to apply the unloading compliance method to a real pipe fracture resistance curve test. The objective of this paper is to propose the calibration equation between the normalized crack length and the normalized electric potential, and to apply to pipe fracture experiments. For these, finite element analyses were performed with various current input locations and crack front configurations. Also the 4-point bending jig was manufactured for a pipe test and the DCPD method was used to measure crack extensions and crack lengths for a pipe test. The calculated crack length by the DCPD method agreed with the measured crack length within 5% error.

J-R Curve Evaluation According to the Crack Length Measurement Techniques Under Reverse Cyclic Loading (역사이클하중하에서의 균열길이 측정법에 따른 파괴저항곡선의 평가)

  • 원종일;우흥식;석창성
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.96-101
    • /
    • 1998
  • J-R curve tests were performed on 1T compact specimens of SA516 Gr. 70 carbon steels under reverse cyclic loading. A Direct-Current Potential Drop (DCPD) method, one of the nondestructive techniques to detect flaw of structure, is being increasingly used for monitoring crack initiation and stable crack growth in typical fracture mechanics specimens for J-R testing. In many aspects this method is simpler than the unloading compliance method. The objective of this paper is to evaluate the J-R Curve according to the crack length measurement techniques under reverse cyclic loading. In order to prove the reliability and repeatability of the DCPD method, the crack length measured by using DCPD method was compared to one determined from unloading compliance. Consequently, this DCPD method correlated well with J-R curves and crack extension measurements determined from unloading compliance method.

  • PDF

Evaluation of Corrosion Fatigue Life of TMCP Steel Using the DCPD Method (DCPD 법을 이용한 TMCP 강의 부식피로수명 평가)

  • Park, Jin-Hyung;Bae, Dong-Ho
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.220-225
    • /
    • 2003
  • In order to develop a method of corrosion fatigue design and estimate reliability of TMCP steel using as the material of heavy industries and plants, its corrosion susceptibilities and corrosion fatigue life considering corrosion degradation were investigated. From the results, the corrosion characteristic of TMCP steel is very susceptible in 3.5wt.% NaCl solution. Its susceptibility was linearly increased with the solution temperature increase. The potential difference due to the crack growth behavior in $25^{\circ}C$, 3.5wt.% NaCl solution is very susceptible. And it was found that stress amplitude has a linear relationship with the critical potential. Therefore, it is expected that the corrosion fatigue life of TMCP steel can be nondestructively predicted using the DCPD method.

  • PDF