J-R Curve Evaluation According to the Crack Length Measurement Techniques Under Reverse Cyclic Loading

역사이클하중하에서의 균열길이 측정법에 따른 파괴저항곡선의 평가

  • 원종일 (산업설비 안전성평가 연구센터) ;
  • 우흥식 (동국대학교 안전공학과) ;
  • 석창성 (성균관대학교 기계공학부)
  • Published : 1998.12.01

Abstract

J-R curve tests were performed on 1T compact specimens of SA516 Gr. 70 carbon steels under reverse cyclic loading. A Direct-Current Potential Drop (DCPD) method, one of the nondestructive techniques to detect flaw of structure, is being increasingly used for monitoring crack initiation and stable crack growth in typical fracture mechanics specimens for J-R testing. In many aspects this method is simpler than the unloading compliance method. The objective of this paper is to evaluate the J-R Curve according to the crack length measurement techniques under reverse cyclic loading. In order to prove the reliability and repeatability of the DCPD method, the crack length measured by using DCPD method was compared to one determined from unloading compliance. Consequently, this DCPD method correlated well with J-R curves and crack extension measurements determined from unloading compliance method.

Keywords