• 제목/요약/키워드: DC-link

검색결과 1,020건 처리시간 0.026초

Voltage Balance Control of Cascaded H-Bridge Rectifier-Based Solid-State Transformer with Vector Refactoring Technology in αβ Frame

  • Wong, Hui;Huang, Wendong;Yin, Li
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.487-496
    • /
    • 2019
  • For a solid-state transformer (SST), some factors, such as signal delay, switching loss and differences in the system parameters, lead to unbalanced DC-link voltages among the cascaded H-bridges (CHB). With a control method implemented in the ${\alpha}{\beta}$ frame, the DC-link voltages are balanced, and the reactive power is equally distributed among all of the H-bridges. Based on the ${\alpha}{\beta}$ frame control, the system can achieve independent active current and reactive current control. In addition, the control method of the high-voltage stage is easy to implement without decoupling or a phase-locked loop. Furthermore, the method can eliminate additional current delays during transients and get the dynamic response rapidly without an imaginary current component. In order to carry out the controller design, the vector refactoring relations that are used to balance DC-link voltages are derived. Different strategies are discussed and simulated under the unbalanced load condition. Finally, a three-cell CHB rectifier is constructed to conduct further research, and the steady and transient experimental results verify the effectiveness and correctness of the proposed method.

유연성 로봇 매니퓰레이터에 대한 비선형 가변구조제어 (Nonlinear variable structure system control for flexible link robot manipulators)

  • 김성태;임규만;함운철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.280-284
    • /
    • 1997
  • In this paper, Nonlinear VSS control based on bang-bang control concept is derived under the assumption that the control input is bounded. We try to derive control algorithm which has almost same performance as the time optimal control. We focus this control scheme on the real implementation of DC motor position controller of flexible link, i.e. we obtain the switching curves from the real data of DC motor system operating under the full maximum and minimum applied voltages. State space is separated into several regions and we set different switching surfaces in each region to reduce chattering problem. The efficiency of the proposed controller is compared with PID controller and it is shown that the controller converges fast than PID controller without chattering. The hybrid controller scheme is also proposed not only to control the position of hub but also to reduce the vibration of end tip of flexible link.

  • PDF

계통전압 불평형시 DFIG를 이용한 풍력발전 시스템의 동적 모델링 및 제어기법 (An improved control strategy for a DFIG in wind turbine under unbalanced condition)

  • 이솔빈;김서형;이교범
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2009년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.200-202
    • /
    • 2009
  • 본 논문은 계통전압 불평형시 이중여자 유도형 풍력발전기 (Doubly Fed Induction Generator-DFIG)의 토크 리플 저감과 dc-link 전압의 맥동을 제거하는 기법을 제안한다. 계통전압 불평형 시 DFIG의 동적 모델링을 통해 토크 맥동 성분과 dc-link 전압 리플 성분을 수식화 한다. 유도된 수식을 기반으로 회전자 측 컨버터는 정상분과 역상분을 독립적으로 제어하는 듀얼 전류 제어기를 통해 토크 리플을 저감하며, 계통 측컨버터는 전력이론을 통해 계산된 보상 전류 지령치를 통해 cd-link 전압 맥동을 제거한다. 3kW급 풍력 발전 시스템에 제안하는 기법을 적용한 시뮬레이션 결과를 통해 타당성을 입증한다.

  • PDF

Link Voltage Adjustment Converter Employing Load Power Estimator for Notebook Computer Adaptor

  • Choi, Seong-Wook;Lee, Byoung-Hee;Lee, Keun-Wook;Ryu, Byoung-Woo;Moon, Gun-Woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.348-350
    • /
    • 2008
  • A link voltage adjustment converter employing load power estimator for notebook computer adaptor is proposed. It is consisted of the boost converter as a power factor correction stage and the LLC resonant converter as a DC/DC conversion stage with a newly introduced link voltage adjustment method employing load power estimator, which helps to reduce the transformer size and peak of output voltage ripple, maintaining high efficiency over all the load condition. Experimental results with 85W converter are given to verify the validity of the proposed circuit.

  • PDF

Three-Phase Four-Wire Inverter Topology with Neutral Point Voltage Stable Module for Unbalanced Load Inhibition

  • Cai, Chunwei;An, Pufeng;Guo, Yuxing;Meng, Fangang
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1315-1324
    • /
    • 2018
  • A novel three-phase four-wire inverter topology is presented in this paper. This topology is equipped with a special capacitor balance grid without magnetic saturation. In response to unbalanced load and unequal split DC-link capacitors problems, a qusi-full-bridge DC/DC topology is applied in the balance grid. By using a high-frequency transformer, the energy transfer within the two split dc-link capacitors is realized. The novel topology makes the voltage across two split dc-link capacitors balanced so that the neutral point voltage ripple is inhibited. Under the condition of a stable neutral point voltage, the three-phase four-wire inverter can be equivalent to three independent single phase inverters. As a result, the three-phase inverter can produce symmetrical voltage waves with an unbalanced load. To avoid forward transformer magnetic saturation, the voltages of the primary and secondary windings are controlled to reverse once during each switching period. Furthermore, an improved mode chosen operating principle for this novel topology is designed and analyzed in detail. The simulated results verified the feasibility of this topology and an experimental inverter has been built to test the power quality produced by this topology. Finally, simulation results verify that the novel topology can effectively improve the inhibition of an inverter with a three-phase unbalanced load while decreasing the value of the split capacitor.

보조 공진 DC 링크 스너버형 컨버터와 3상 전압형 인버터의 전력손실분석 (Auxiliary resonant DC Link and power loss analysis of three phase voltage type inverter)

  • 김주용;문상필;김영문;이현우;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1064-1066
    • /
    • 2002
  • This paper proposes a new prototype auxiliary resonant DC link(ARDCL)snubber circuit and deals with its power loss on the basis of actually measured conduction loss characteristic of switching device module. Voltage type soft switching three phase inverter using proposed ARDCL snubber circuit is presented along with its performance evaluations. And, the power loss analysis of three phase hard and soft switching inverter are carried out from the point of simulation and experimental results.

  • PDF

DC전압 충전 및 전원 역률 보상이 가능한 APF에 관한 연구 (A study on Active Power Filter Available for DC-Link Boost and Power Factor Control)

  • 이우철
    • 조명전기설비학회논문지
    • /
    • 제27권1호
    • /
    • pp.53-60
    • /
    • 2013
  • In this paper, a control algorithm for active power filter (APF), which compensates for the harmonics and power factor, boosting the DC-link voltage is proposed. The proposed scheme employs a pulse-width-modulation (PWM) voltage-source inverter. A simple algorithm to detect the load current harmonics is also proposed. The APF and charging circuit are implemented in one inverter system. Finally, the validity of the proposed scheme is investigated with simulated and experimental results for a prototype APF system rated at 3kVA.

Space Vector Modulated Three-Phase Soft-Switching Active Rectifier and Its Performance Evaluations

  • Fujii Yuma;Ahmed Tarek;Imamura Kosuke;Hiraki Eiji;Nakaoka Mutsuo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.213-215
    • /
    • 2003
  • This paper presents an instantaneous space vector modulated voltage source type three-phase soft-switching PFC rectifier using a single auxiliary resonant DC Link snubber for alternative energy utilizations. in the first place, the operating principle of an active auxiliary resonant DC link snubber circuit is described including its unique features. In the next place, the simulation analysis of three-phase soft-switching PWM rectifier is implemented, and the operating performances or the three-phase voltage-fed PWM rectifier treated here, which can operate under the conditions of sinewave line current shaping and utility power factor are evaluated and discussed on tile basis of this simulation results.

  • PDF

DC-링크 전압균형과 최소 온-오프 시간을 고려한 새로운 3-레벨 GTO 인버터 제어기법 (A New Switching Method for 3-level GTO Inverter Considering DC-link Voltage Balancing and Minimum on/off time)

  • 이요한;현동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.373-375
    • /
    • 1994
  • In realizing a three-level GTO inverter, we should keep the voltage balancing of DC-link capacitors and consider minimum on/off time of GTO thyristors in order to make the same blocking voltage across each device and to minimize the harmonic components of the output voltage and current. In this raper, a new PWM scheme based on space voltage vectors, by which it is possible to keep neutral-point voltage and avoid narrow pulse, is presented. Experimental results verify that the proposed PWM control scheme is suitable fur hish power and high voltage three-level GTO inverters applied to induction motor drives.

  • PDF

500kW 풍력발전용 전력변환장치 시스템 개발 (500kW Wind Power Conversion System Development)

  • 최미선;곽상현;문준선;오용승;안강순
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.529-530
    • /
    • 2011
  • 본 논문에서는 대용량 및 장거리 송전을 위한 풍력발전용 MVDC 전력변환 시스템을 제안한다. 이 시스템은 컨버터, 인버터, DC Link, LC필터로 구성되어 있으며 풍력 발전기에서 발생되는 전압을 컨버터가 동작하여 DC 2000V로 제어한다. 변환된 DC Link의 전압은 인버터에서 AC 380V로 변환하여 계통에 연계된다. 제안된 방식의 타당성 검증하기 위해 500[kW]급 풍력발전용 인버터를 제작 및 실험하였다.

  • PDF