• Title/Summary/Keyword: DC-bus voltage

Search Result 185, Processing Time 0.024 seconds

Reduced Rating T-Connected Autotransformer Based Thirty-Pulse AC-DC Converter for Vector Controlled Induction Motor Drives

  • Singh Bhim;Bhuvaneswari G.;Garg Vipin
    • Journal of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.214-225
    • /
    • 2006
  • The design and performance analysis of a reduced rating autotransformer based thirty-pulse AC-DC converter is carried out for feeding a vector controlled induction motor drive (VCIMD). The configuration of the proposed autotransformer consists of only two single phase transformers, with their windings connected in a T-shape, resulting in simplicity in design, manufacturing and in a reduction in magnetics rating. The design procedure of the autotransformer along with the newly designed interphase transformer is presented. The proposed configuration has flexibility in varying the transformer output voltage ratios as required. The design of the autotransformer can be modified for retrofit applications, where presently a 6-pulse diode bridge rectifier is used. The proposed thirty-pulse AC-DC converter is capable of suppressing less than $29^{th}$ harmonics in the supply current. The power factor is also improved to near unity in the wide operating range of the drive. A comparison of different power quality indices at AC mains and DC bus is demonstrated in a conventional 6-pulse AC-DC converter and the proposed AC-DC converter feeding a VCIMD. A laboratory prototype of the proposed autotransformer based 30-pulse AC-DC converter was developed with test results validating the proposed design and system.

Phase-Shift Full-Bridge DC/DC Converter with Fixed-Phase Operation Inverter (고정 위상 동작 인버터를 포함하는 위상천이 풀 브리지 DC/DC 컨버터)

  • Kim, Jin-Ho;Park, Jae-Sung;Kim, Hong-Kwon;Park, Jun-Woo;Shin, Yong-Saeng;Ji, Sang-Keun;Cho, Sang-Ho;Roh, Chung-Wook;Hong, Sung-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.131-137
    • /
    • 2013
  • In this paper, the phase-shift full-bridge DC/DC converter with fixed-phase operation inverter is proposed. The proposed circuit consists of two full-bridge inverters which are connected in parallel. While one full-bridge inverter operates as the fixed-phase, it regulates the output voltage by adjusting the phase of the other inverter. During the normal operation period, the proposed circuit makes the less amount of conduction loss of the primary switches and secondary synchronous rectifiers, as well as the less amount of the current ripple of the output inductor, than the conventional phase-shift full-bridge DC/DC converter does. Also, it achieves high efficiency by reducing the snubber loss of the secondary synchronous rectifier. To sum up, the present inquiry analyzes the theoretical characteristics of the proposed circuit, and shows the experimental results from a prototype for 450W power supply.

A Simplified Control Algorithm for Three-Phase, Four-Wire Unified Power Quality Conditioner

  • Singh, Bhim;Venkateswarlu, P.
    • Journal of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.91-96
    • /
    • 2010
  • In this paper, a simplified control algorithm for a three-phase, four-wire unified power quality conditioner (UPQC) is presented to compensate for supply voltage distortions/unbalance, supply current harmonics, the supply neutral current, the reactive power and the load unbalance as well as to maintain zero voltage regulation (ZVR) at the point of common coupling (PCC). The UPQC is realized by the integration of series and shunt active filters (AFs) sharing a common dc bus capacitor. The shunt AF is realized using a three-phase, four leg voltage source inverter (VSI) and the series AF is realized using a three-phase, three leg VSI. A dynamic model of the UPQC is developed in the MATLAB/SIMULINK environment and the simulation results demonstrating the power quality improvement in the system are presented for different supply and load conditions.

Study on SCR Type High Speed DC Circuit Breaker Using Bus Voltage (모선 전압을 이용한 SCR Type 고속 DC 차단기 연구)

  • Ju, Hong-Ju;Kim, Soo-Yeon;Kang, Seong-Yong;Kim, Kuk-Hyeon;Park, Seong-Mi;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.325-326
    • /
    • 2017
  • 태양광 발전의 DC 전압 출력 및 케이블을 이용한 해상풍력 발전과 같은 신재생 에너지 이용이 증대되고 있다. 또한, 에너지의 전력전송 대용량화에 따른 기존의 AC 전력전송 방식을 개선한 DC 전력전송에 대한 연구가 활발히 연구되고 있다. DC 전력전송은 송전선로의 원거리화 및 절연내력의 저감과 같은 장점이 있으나, 전류 차단 시 큰 아크로 인하여 고속차단기 구성이 매우 어렵다는 단점이 있다. 최근에는 DC 전력전송에 있어서 큰 과제인 고속차단을 위해 전자식 차단기에 대한 연구가 이루어지고 있다. 이러한 전자식 차단기를 구성할 경우 차단기 투입 시 큰 돌입전류와 입출력 절연저항이 기존 차단기보다 낮아지는 단점으로 인해 매우 큰 아크가 발생한다. 본 논문에서는 고 전압 대 전류에 적합하고 피크성 전압/전류에 강인한 소자인 SCR을 이용한 전자식 DC 차단기 연구를 진행하였다.

  • PDF

A Novel Type of Discrete Time Predictive Current Controllers for Parallel Resonant Inverters (병렬 공진형 인버터에서 사용되는 새로운 형태의 이산시간 예측 전류 제어기)

  • Huh, Sung-Hoi;Choy, Ick;Kim, Kwon-Ho;Ahn, Hyun-Sik;Kim, Do-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.309-311
    • /
    • 1996
  • In this paper, we propose two types of novel discrete time current control methods of modified fixed band hysteresis control and optimal control for Parallel Resonant DC Link Inverters(PRDCLI). Because zero bus voltage intervals are generated on the DC link of PRDCLI, we can obtain the information of counter electromotive force(emf) by a simple estimation strategy. The proposed current controllers predict the currents of the next resonant cycle using the obstained information of counter emf and the average values of DC link voltages. The computer simulation results for a simple equivalent circuit of induction motor show that the proposed control methods are more effective than conventional methods.

  • PDF

A Novel Flyback-type Utility Interactive Inverter for AC Module Systems

  • Shimizu Toshihisa;Nakamura Naoki;Wada Keiji
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.518-522
    • /
    • 2001
  • In recent years, natural energy has attracted growing interest because of environmental concerns. Many studies have been focused on photovoltaic power generation systems because of the ease of use in urban areas. On the conventional system, many photovoltaic modules (PV modules) are connected in series in order to obtain the sufficient DC-bus voltage for generating AC output voltage at the inverter circuit. However, the total generation power on the PV modules sometimes decreases remarkably because of the shadows that partially cover the PV modules. In order to overcome this drawback, an AC module strategy is proposed. On this system, a small power DC-AC utility interactive inverter is mounted on each PV module individually and the inverter operates so as to generate the maximum power from the corresponding PV module. This paper presents a novel flyback-type utility interactive inverter circuit suitable for AC module systems. The feature of the proposed system are, (1) small in volume and light in weight, (2) stable AC current injection, (3) enabling a small DC capacitor. The effectiveness of the proposed system is clarified through the simulation and the experiments.

  • PDF

Design and Analysis of Large Induction Motor Control Coping with Voltage Sag (순간전압강하 극복을 위한 대용량 유도전동기 제어방식 설계 및 해석)

  • Cho, Sung-Don;Lim, Seong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1056-1058
    • /
    • 1998
  • Voltage dips caused by transmission system faults are usually of a short duration. High speed relaying and breaker operation will typically limit the disturbance to 0.1 seconds. Most motor controllers obtain their control power directly from the bus by means of a control transformer. Under this condition, a voltage dip can cause the contactor to drop out. disconnecting the motor from the line. The rapid re-energizing of the controller is in effect a fast reclosure which may result in motor damage. The time delay re-energizing of controller will result in a greater loss of speed and possibly loss of stability. Other means of controller can be used to prevent the motor from being disconnected from line during the fault. This can be accomplished by DC power controller or mechanically latched controller. This paper demonstrates that DC power controller or mechanically latched type controller to prevent the motor from being disconnected from line during the fault is, the most effective in minimizing speed reduction, transient motor current, transient motor torque and transient shaft torque by EMTP calculation.

  • PDF

Harmonic Waveforms Analysis and Efficiency Measurement of Inverter for driving Induction Motors (유도형 모터 구동용 인버터의 고조파 파형 분석과 효율 측정)

  • Jang, Seok-Myeong;Jeong, Sang-Sub;Park, Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.282-284
    • /
    • 1997
  • The harmonics are injurious on the operation of the motor, electric instruments etc. In this paper, it is certified the capability of the electric measuring devices at the input/output of inverter. And it is measured the harmonics of the voltage and current waveforms. Also, this paper presents the efficiency of the inverter's power conversion by measuring the fundamental and total power at the input, DC bus and output.

  • PDF

Control Scheme for Suppressing Bus-Voltage Oscillations in DC Microgrids (직류 마이크로그리드의 버스 전압 진동 억제를 위한 제어 기법)

  • Jeung, Yoon-Cheul;Jung, Choul-Woo;Lee, Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.107-109
    • /
    • 2019
  • 본 논문에서는 직류 마이크로그리드의 버스 전압 진동을 감쇠하기 위한 에너지 저장장치의 제어기법을 제시한다. IDA-PBC 이론을 이용한 제어기를 설계하고, 직류 마이크로그리드의 안정도를 해석한다. PSIM 시뮬레이션을 이용하여 제안하는 기법의 타당성을 검증하였다.

  • PDF

A Three-Phase Four-Wire DSTATCOM for Power Quality Improvement

  • Singh, Bhim;Jayaprakash, P.;Kothari, D.P.
    • Journal of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.259-267
    • /
    • 2008
  • Power quality improvement in a three-phase four-wire system is achieved using a new topology of DSTATCOM (distribution static compensator) consisting of a star/delta transformer with a tertiary winding and a three-leg VSC (voltage source converter). This new topology of DSTATCOM is proposed for power factor correction or voltage regulation along with harmonic elimination, load balancing and neutral current compensation. A tertiary winding is introduced in each phase for a delta connected secondary in addition to the star-star windings and this delta connected winding is responsible for neutral current compensation. The dynamic performance of the proposed DSTATCOM system is demonstrated using MATLAB with its Simulink and Power System Blockset (PSB) toolboxes under varying loads. The capacitor supported DC bus of the DSTATCOM is regulated to the reference voltage under varying loads.