• 제목/요약/키워드: DC voltage

검색결과 4,532건 처리시간 0.026초

Plasma source ion implantations for shallow $p^+$/n junction

  • Jeonghee Cho;Seuunghee Han;Lee, Yeonhee;Kim, Lk-Kyung;Kim, Gon-Ho;Kim, Young-Woo;Hyuneui Lim;Moojin Suh
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2000년도 제18회 학술발표회 논문개요집
    • /
    • pp.180-180
    • /
    • 2000
  • Plasma source ion implantation is a new doping technique for the formation of shallow junction with the merits of high dose rate, low-cost and minimal wafer charging damage. In plasma source ion implantation process, the wafer is placed directly in the plasma of the appropriate dopant ions. Negative pulse bias is applied to the wafer, causing the dopant ions to be accelerated toward the wafer and implanted below the surface. In this work, inductively couples plasma was generated by anodized Al antenna that was located inside the vacuum chamber. The outside wall of Al chamber was surrounded by Nd-Fe-B permanent magnets to confine the plasma and to enhance the uniformity. Before implantation, the wafer was pre-sputtered using DC bias of 300B in Ar plasma in order to eliminate the native oxide. After cleaning, B2H6 (5%)/H2 plasma and negative pulse bias of -1kV to 5 kV were used to form shallow p+/n junction at the boron dose of 1$\times$1015 to 5$\times$1016 #/cm2. The as-implanted samples were annealed at 90$0^{\circ}C$, 95$0^{\circ}C$ and 100$0^{\circ}C$during various annealing time with rapid thermal process. After annealing, the sheet resistance and the junction depth were measured with four point probe and secondary ion mass spectroscopy, respectively. The doping uniformity was also investigated. In addition, the electrical characteristics were measured for Schottky diode with a current-voltage meter.

  • PDF

Improved Uniformity in Resistive Switching Characteristics of GeSe Thin Film by Ag Nanocrystals

  • Park, Ye-Na;Shin, Tae-Jun;Lee, Hyun-Jin;Lee, Ji-Soo;Jeong, Yong-Ki;Ahn, So-Hyun;Lee, On-You;Kim, Jang-Han;Nam, Ki-Hyun;Chung, Hong-Bay
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.237.2-237.2
    • /
    • 2013
  • ReRAM cell, also known as conductive bridging RAM (CBRAM), is a resistive switching memory based on non-volatile formation and dissolution of conductive filament in a solid electrolyte [1,2]. Especially, Chalcogenide-based ReRAM have become a promising candidate due to the simple structure, high density and low power operation than other types of ReRAM but the uniformity of switching parameter is undesirable. It is because diffusion of ions from anode to cathode in solid electrolyte layer is random [3]. That is to say, the formation of conductive filament is not go through the same paths in each switching cycle which is one of the major obstacles for performance improvement of ReRAM devices. Therefore, to control of nonuniform conductive filament formation is a key point to achieve a high performance ReRAM. In this paper, we demonstrated the enhanced repeatable bipolar resistive switching memory characteristics by spreading the Ag nanocrystals (Ag NCs) on amorphous GeSe layer compared to the conventional Ag/GeSe/Pt structure without Ag NCs. The Ag NCs and Ag top electrode act as a metal supply source of our devices. Excellent resistive switching memory characteristics were obtained and improvement of voltage distribution was achieved from the Al/Ag NCs/GeSe/Pt structure. At the same time, a stable DC endurance (>100 cycles) and an excellent data retention (>104 sec) properties was found from the Al/Ag NCs/GeSe/ Pt structured ReRAMs.

  • PDF

정역전이 가능한 SCR 서보증폭기에 관한 연구 (A Study on the Reversible SCR Servo Amplifier)

  • 안병원;박상길
    • 수산해양기술연구
    • /
    • 제31권2호
    • /
    • pp.190-198
    • /
    • 1995
  • 전원을 단락시킴이 없는 SCR이중 브리지 트리거 방식을 고안하여, 정역전이 가능한 SCR 서보증폭기로 구성하여 본 결과 다음과 같은 결론을 내릴 수 있었다. I. 출력전압의 부호를 변경시킬 때 현재의 전언부호가 반전될 때까지 도통 상태를 유지시키다가, 전원부호가 반전된 이후 적절한 SCR을 도통 시킴으로서 크리거 실패가 없게 되어, 전원을 단락시키지 않게 되고 SCR의 소손을 막을 수 있었다. II. -에서 약 30Hz 부근까지는 60Hz의 전원으로서 원하는 출력을 표현할 수 있었는데, 이는 대형 직류 전동기의 동특성을 충분히 확보할 수 있는 값이다. III. 유도성 부하의 경우라도 이미 도통된 SCR을 통하여 유동성부하L에 저장될 수 있는 에너지의 총량은 전원의 반주기 시간과 전원이 파고치값 한계내이므로, 다음 반주기동안 부호만 반전된 전원 전압과 동일한 반주기의 시간이 존재하므로, 에너지 보존의 법칙에 의해 반드시 다음 반주기 안에 현재도통된 SCR은 소호되게 되므로 트리거실패는 존재하지 않는다.

  • PDF

화재감지데이터 전송용 USN망 구축을 위한 지그비 센서노드 구현 (A Study on the Implementation of Zigbee Sensor Node for Building USN Using only Transmission of Fire Sensing Data)

  • 천동진;정도영;곽동걸
    • 한국화재소방학회논문지
    • /
    • 제23권6호
    • /
    • pp.75-81
    • /
    • 2009
  • 화재감지 데이터 전송에 있어서 기존의 유선기반의 전송선로보다 설치에 용이하고 다양한 정보수집에 효율성이 높은 무선기반의 USN망이 대안으로 제시되고 있다. 그러나 USN망 구축에 사용되는 센서노드의 무선전송거리 및 정보의 신뢰성에 대해서는 문제점이 대두되고 있다. 본 연구에서는 국제적 표준규격 지그비 프로토콜을 사용하여 센서노드를 구현하였다. 제안한 센서노드 사이에 전송거리 및 수신된 정보의 신뢰성을 검증하고자 테스트 전압 3V와 5V를 센서노드 입력단자에 인가하고, 실내에서 10m씩 거리를 증가시켜 실험한 결과 최대 유효전송거리가 90m 내외임을 확인하였다. 또한, Mesh Routing 중계센서노드를 사용했을 때 전송거리에는 제한이 없었다. 제안한 센서노드로 USN망을 구축하고 실제 화재감지센서를 센서노드 입력단자에 연결하여 전송하였을 때 센서에서 직접측정 한 데이터와 USN망으로 전송하여 수집된 화재감지데이터가 잘 일치하였다. 따라서 제안한 센서노드의 화재감지정보 전송용 USN망 구축에 있어서 전송거리 및 정보의 신뢰성이 확인 되었다.

A Low-noise Multichannel Magnetocardiogram System for the Diagnosis of Heart Electric Activity

  • Lee, Yong-Ho;Kim, Ki-Woong;Kim, Jin-Mok;Kwon, Hyuk-Chan;Yu, Kwon-Kyu;Kim, In-Seon;Park, Yong-Ki
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권4호
    • /
    • pp.154-163
    • /
    • 2006
  • A 64-channel magnetocardiogram (MCG) system using low-noise superconducting quantum interference device (SQUID) planar gradiometers was developed for the measurements of cardiac magnetic fields generated by the heart electric activity. Owing to high flux-to-voltage transfers of double relaxation oscillation SQUID (DROS) sensors, the flux-locked loop electronics for SQUID operation could be made simpler than that of conventional DC SQUIDs, and the SQUID control was done automatically through a fiber-optic cable. The pickup coils are first-order planar gradiometers with a baseline of 4 em. The insert has 64 planar gradiometers as the sensing channels and were arranged to measure MCG field components tangential to the chest surface. When the 64-channel insert was in operation everyday, the average boil-off rate of the dewar was 3.6 Lid. The noise spectrum of the SQUID planar gradiometer system was about 5 fT$_{rms}$/$\checkmark$Hz at 100 Hz, operated inside a moderately shielded room. The MCG measurements were done at a sampling rate of 500 Hz or 1 kHz, and realtime display of MCG traces and heart rate were displayed. After the acquisition, magnetic field mapping and current mapping could be done. From the magnetic and current information, parameters for the diagnosis of myocardial ischemia were evaluated to be compared with other diagnostic methods.

태양광 어레이 I-V 곡선 측정을 위한 다채널 동시 측정방법에 관한 연구 (The Study of Method about the Multi-channel Simultaneous Measurement for Measuring the I-V Curve of Photovoltaic Array)

  • 박유나;장길수;고석환;강기환;소정훈;정영석;주영철;황혜미;송형준
    • 한국태양에너지학회 논문집
    • /
    • 제37권4호
    • /
    • pp.23-33
    • /
    • 2017
  • A great deal of study for loss reduction of photovoltaic system is conducted currently. It is hard to distinct the fault of photovoltaic system with the naked eye. For that reason, it is essential to repair and maintain the PV system by monitoring the system. The fault of individual modules can cause the huge loss of the entire system because of the mismatch. Therefore, the method of diagnosing the PV array is necessary by measuring the multi-channel arrays simultaneously. In this paper, it is presented the method of measuring I-V curve of multi-channel arrays simultaneously by using the charge and discharge characteristics of capacitor. Generated DC power at PV arrays is charged and discharged at the capacitors in a moment. By measuring the charged voltage and current, it is possible to diagnose of performance of PV arrays.

알츠하이머병 쥐 모델에서 경두개 직류 전기자극의 효용성 검토 (Review : Effectiveness of transcranial direct current stimulation in rodent models of Alzheimer's disease)

  • 김지은;박예은;정진형;이상식
    • 한국정보전자통신기술학회논문지
    • /
    • 제14권5호
    • /
    • pp.403-412
    • /
    • 2021
  • 알츠하이머병은 치매를 일으키는 원인 중 가장 높은 빈도를 차지하는 신경퇴행성 질환으로서, 아직은 증상을 개선시키는 정도의 약물적 치료가 주를 이룬다. 이러한 경구약제의 치료적 한계성 및 신약개발의 어려움에 직면하여 임상에서는 비약물적 치료에 대한 관심이 높아지고 있다. 경두개 직류전기자극(transcranial direct current stimulation, tDCS)는 낮은 강도의 직류전류를 이용한 비침습적 뇌조절술의 한 종류로서, 그 안전성에 대해서는 이미 널리 입증받은 바 있다. 본 종설에서는 알츠하이머병 쥐 모델에게 tDCS를 적용함으로써 얻을 수 있는 행동학적, 신경생리학적, 뇌조직학적 회복에 대한 객관적 근거들을 살펴봄으로써, 인간 대상 tDCS연구의 배경근거를 제시하고자 한다.

Protection properties of HTS coil charging by rotary HTS flux pump in charging and compensation modes

  • Han, Seunghak;Kim, Ji Hyung;Chae, Yoon Seok;Quach, Huu Luong;Yoon, Yong Soo;Kim, Ho Min
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권4호
    • /
    • pp.19-24
    • /
    • 2021
  • The low normal zone propagation velocity (NZPV) of high-temperature superconducting (HTS) tape leads to a quench protection problem in HTS magnet applications. To overcome this limitation, various studies were conducted on HTS coils without turn-to-turn insulation (NI coils) that can achieve self-protection. On the other hand, NI coils have some disadvantages such as slow charging and discharging time. Previously, the HTS coils with turn-to-turn insulation (INS coils) were operated in power supply (PS) driven mode, which requires physical contact with the external PS at room-temperature, not in persistent current mode. When a quench occurs in INS coils, the low NZPV delays quench detection and protection, thereby damaging the coils. However, the rotary HTS flux pump supplies the DC voltage to the superconducting circuit with INS coils in a non-contact manner, which causes the INS coils to operate in a persistent current mode, while enabling quench protection. In this paper, a new protection characteristic of HTS coils is investigated with INS coils charging through the rotary HTS flux pump. To experimentally verify the quench protection characteristic of the INS coil, we investigated the current magnitude of the superconducting circuit through a quench, which was intentionally generated by thermal disturbances in the INS coil under charging or steady state. Our results confirmed the protection characteristic of INS coils using a rotary HTS flux pump.

화력 발전소 고전압 케이블 접속재의 On-Line 직류 누설 전류 시스템 개발과 진단 Factor에 관한 연구 (A Study on Development and Diagnosis Factors of On-Line DC Leakage Current System for Junctions of High-Voltage Cables in Operation at Thermoelectric Power Station)

  • 박성희;엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제18권6호
    • /
    • pp.187-193
    • /
    • 2018
  • 국내에서의 전력에 대한 수요는 점진적으로 증가하고 있는 추세이다. 수요에 대응하기 위한 발전소는 기능이 다양해지고 효율이 점차 커져야 한다. 발전소 내의 전력 기기에서 사고가 발생하면 막대한 경제적 손실 및 장애를 초래하게 된다. 사고 발생의 원인 중의 하나로서 절연 성능이 저하 된 케이블이 있다. 케이블 사고를 미연에 방지하기 위하여 절연의 상태를 감시하고 확인하여야 한다. 케이블 사고는 연결 부위인 접속에서 발생하는 사고가 대부분을 차지한다. 본 연구와 관련하여 우리는 접속부 상태를 판별하기 위한 장비를 개발하였고, 한국서부발전(주)의 현장에 설치하여 운용 중이다. 본 논문에서는 현장에서 설치 운용 중인 장비에 대한 설명과 더불어 설치 운용된 결과를 통해 케이블의 수명을 예측할 수 있는 고전압 케이블 접속재의 안정적 사용을 위한 온라인 감시진단기법 중에서 사고가 가장 빈번하게 발생하는 접속부에 대해 안정적인 사용을 위한 진단의 정확성과 신뢰성을 향상시키기 위한 연구를 하였다. 이 논문에서 하드웨어 구성을 위주로 우리가 개발한 장비를 소개한다.

A Study on the Insulation Characteristics of Epoxy Composites Using Electric Field Simulation

  • Lee, Deok-Jin
    • 한국컴퓨터정보학회논문지
    • /
    • 제26권2호
    • /
    • pp.53-60
    • /
    • 2021
  • 본 논문에서는 전기 전자부품 및 기구의 절연재료로 널리 적용되고 있는 에폭시 복합재료의 절연 특성 및 신뢰도를 파악하고자 한다. 이를 위해 경제적, 기계적 요인에 의해 필수적으로 첨가되어야 하는 충진재의 분포에 따른 전계 변화를 예측하기 위하여 전계해석 시뮬레이터를 이용하여 그 결과를 확인하였다. 또한 직류 전압 인가 조건하에서 주변 온도 변화 및 충진재 분포에 따른 절연파괴시험을 수행하였고 그 변화를 관찰하였다. 시편은 에폭시 수지에 충진재를 0, 50, 100[phr] 첨가하여 3종류가 제작되었으며 모든 시편의 경우에서 온도가 증가함에 따라 절연파괴강도가 저하됨을 확인하였다. 시뮬레이션 결과 및 실제 절연강도시험 결과를 비교 고찰하여 전기 기구의 절연설계에 필요한 기술적 적용 가능성을 확인하였다.