• Title/Summary/Keyword: DC link inverter

Search Result 449, Processing Time 0.033 seconds

A New Quasi-Resonant M Link Inverter (새로운 Quasi-Resonant DC Link 인버터)

  • Lee, J.J.;Lee, J.W.;Park, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.328-331
    • /
    • 1990
  • A new quasi-resonant do link inverter is suggested, which can operate at the constant peak do link voltage irrespective of the magnitude of load current. The inverter is analyzed by using the topological analogy between the proposed inverter and the resonant DC/DC converter. Based on the analysis, an appropriate current controller is developed, which results in low current stress to the resonant capacitor and also enjoys the inherent capability of the current initialization of resonant inductor. For the purpose of confirming the inverter characteristics, some simulation results are presented.

  • PDF

A Multilevel Inverter Using DC Link Voltage Combination (DC링크 전압 조합을 이용한 멀티 레벨 인버터)

  • Joo S.Y.;Lee J.H.;Kang F.S.;Kim C.U.;Park S.J.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.621-624
    • /
    • 2003
  • In this paper, a novel multilevel inverter using DC-Link voltage combination is presented to reduce the harmonics of output voltage without the output filter inductor. The proposed multilevel inverter can generate 27-level output voltage. It employs three H-bridge cells which consist of single phase full-bridge inverter module. As well as, it can make continuous output voltage level employing the properly three DC-Link voltage ratio. The validity of the proposed inverter is verified through the experimental result using a prototype which can generate a 110[Vac], 60[Hz] output voltage from 12[Vdc], 36[vdc], and 108[Vdc] input voltages

  • PDF

A Ringing Surge Clamper Type Active Auxiliary Edge-Resonant DC Link Snubber-Assisted Three-Phase Soft-Switching Inverter using IGBT-IPM for AC Servo Driver

  • Yoshitsugu, Junji;Yoshida, Masanobu;Hiraki, Eiji;Inoue, Kenji;Ahmed, Tarek;Nakaoka, Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.3
    • /
    • pp.115-124
    • /
    • 2002
  • This paper presents an active auxiliary edge-resonant DC link snubber with a ringing surge damper and a three-phase voltage source type zero voltage soft-switching inverter with the resonat snubber treated here for the AC servo motor driver applications. The operation of the active auxiliary edge-resonant DC link snubber circuit with PWM voltage is described, together with the practical design method to select its circuit parameters. The three-phase voltage source type soft-switching inverter with a single edge-resonant DC link snubber treated here is evaluated and discussed for the small-scale permanent magnet (PM) type-AC servo motor driver from an experimental point of view. In addition to these, the AC motor stator current and its motor speed response for the proposed three-phase soft-switching inverter employing Intelligent Power Module(IPM) based on IGBTS are compared with those of the conventional three-phase hard-switching inverter using IPM. The practical effectiveness of the three-phase soft-switching inverter-fed permanent magnet type AC motor speed tracking servo driver is proven on the basis of the common mode current in a novel type three-phase soft-switching inverter-fed AC motor side and the conductive noise on the mains terminal interface voltage as compared with those of the conventional three-phase hard-switching inverter-fed permanent magnet type AC servo motor driver for the speed tracking applications.

The Experimental Consideration about Loss of Three-phase Voltage-fed Inverter using Auxiliary Resonant DC Link (ARDCL을 이용한 3상 전압형 인버터의 손실에 관한 실험적 고찰)

  • 서기영;문상필;김주용;이상현;박영조
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.100-105
    • /
    • 2003
  • This paper proposes a new auxiliary resonant DC link(ARDCL)snubber circuit and deals with its power loss on the basis of actually-measured conduction loss characteristic of switching device module. Voltage-fed soft switching three-phase inverter using proposed ARDCL snubber circuit is presented along with its performance evaluations. And, the power loss analysis of three-phase hard and soft switching inverter are carried out from the point of simulation and experimental results.

Minimum DC-Link Filter in Three-phase PWM Voltage Source Inverter for Induction Motor Drive (유도 전동기 구동 시스템을 위한 PWM전압원 인버터 DC-링크 필터 설계)

  • Kim, Kwang-Seob;Suh, Bum-Seok;Hyun, Dong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.495-497
    • /
    • 1994
  • Given the constraint of the AC input power factor and the DC-link voltage and current ripple in voltage source inverter, minimizing the size and cost of the DC-link fitter components is very important. This paper presents a procedure for the selection of DC-link filler element values in a three-phase PWM voltage source inverter-fed induction motor drive system, which can not only satisfy the requirements for the system performance but also minimize the filter size.

  • PDF

Fault Diagnosis of DC Link Electrolytic Capacitors in Inverter (인버터의 직류단 전해 커패시터 고장 진단)

  • Yang, Jin-Kyu
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.145-152
    • /
    • 2013
  • Electrolytic capacitors used for smoothing DC link voltage is one of the major root causes of fault in power electronic system. The aging of aluminum electrolytic capacitors is expressed by the increase of their equivalent series resistance (ESR) and the reduction of their capacitance. Thus, the proposed technique in this paper is to measure capacitance, by comparing energy loss of DC link capacitors with stator resistor in electric machine. Condition of DC link capacitors can be estimated from the capacitance decrease rate between initial and aged capacitors. The results show that the proposed technique provides an easy, widely applicable and simple low cost solution for detecting dc link capacitor degradation.

Comparative Analysis of Pulse Width Modulation Methods for Improving the Lifetime of DC-link Capacitors of NPC Inverters (NPC 인버터의 DC-link 커패시터 수명 향상을 위한 전압 변조 방법 비교 평가)

  • Choi, Jae-Heon;Choi, Ui-Min
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.4
    • /
    • pp.291-296
    • /
    • 2022
  • Capacitor is one of the reliability-critical components in power converters. The lifetime of the capacitor decreases as the operating temperature increases, and power losses caused by capacitor current are the main cause of the capacitor temperature increase. Therefore, various studies are being conducted to improve the lifetime of the capacitor by reducing the current of DC-link capacitors. In this study, pulse width modulation methods proposed for improving the lifetime of DC-link capacitors of the three-level NPC inverter are comparatively analyzed. The lifetime evaluation of the DC-link capacitor under different modulation methods is performed at component level first and then system level by considering all capacitors by applying Monte Carlo simulation. Furthermore, their effects on the efficiency and THD of the output current are also considered.

Digital Control of Utility-Connected PV Inverter (계통 연계형 태양광 발전 인버터의 디지털 제어)

  • Kim Yong-Kyun;Chol Jong-Woo;Kim Heung-Geun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1161-1165
    • /
    • 2004
  • The fundamental digital control of utility-connected PV inverter are presented with detailed analysis and simulation and experimental results. PLL controller using virtual two phase detector, current controller of DC-DC converter, dc link voltage controller and inverter current controller are discussed. The novel PLL controller using virtual two phase detector can detect the information of utility voltage instantaneously and is not sensitive to the noise. Current controller of DC-DC converter, dc link voltage controller and inverter current controller are the conventional methods. We have constructed utility-Connected PV Inverter and applied to those controllers. The simulation and experimental results demonstrate an excellent performance in the single-phase grid-connected operation.

  • PDF

Dual Utility AC Line Voltage Operated Voltage Source and Soft Switching PWM DC-DC Converter with High Frequency Transformer Link for Arc Welding Equipment

  • Morimoto Keiki;Ahmed NabilA.;Lee Hyun-Woo;Nakaoka Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.366-373
    • /
    • 2005
  • This paper presents two new circuit topologies of the dc busline side active resonant snubber assisted voltage source high frequency link soft switching PWM full-bridge dc-dc power converters acceptable for either utility ac 200V-rms or ac 400V-rms input grid. These high frequency switching dc-dc converters proposed in this paper are composed of a typical voltage source-fed full-bridge PWM inverter, high frequency transformer with center tap, high frequency diode rectifier with inductor input filter and dc busline side series switches with the aid of a dc busline parallel capacitive lossless snubber. All the active switches in the full-bridge arms as well as dc busline snubber can achieve ZCS turn-on and ZVS turn-off transition commutation with the aid of a transformer leakage inductive component and consequently the total switching power losses can be effectively reduced. So that, a high switching frequency operation of IGBTs in the voltage source full bridge inverter can be actually designed more than about 20 kHz. It is confirmed that the more the switching frequency of full-bridge soft switching inverter increases, the more soft switching PWM dc-dc converter with a high frequency transformer link has remarkable advantages for its power conversion efficiency and power density implementations as compared with the conventional hard switching PWM inverter type dc-dc power converter. The effectiveness of these new dc-dc power converter topologies can be proved to be more suitable for low voltage and large current dc-dc power supply as arc welding equipment from a practical point of view.

A Study on Improving Characteristics in the Parallel Resonant DC Link Inverter (병렬공진형 직류 링크 인버터의 특성 개선에 관한 연구)

  • Beak, J.W.;Yoo, D.W.;Kim, J.S.;Lim, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.429-431
    • /
    • 1994
  • A parallel resonant dc link inverter, one of the many resonant inverters, has some superior characteristics in camparision with other resonant inverters. But loss of the resonant oscillation and occurrence of high peak voltage in the resonant capacitor of these inverters are serious problems. In this paper, we investigate a control method for resonant dc link inverters which can overcome these problems. Experimental results are presented to show superior operation of the resonant dc link inverter using the proposed control method.

  • PDF