• 제목/요약/키워드: DC charge

검색결과 391건 처리시간 0.022초

전하 제어를 적용한 비대칭 하프 브리지 직류-직류 컨버터 (An Asymmetrical Half-Bridge Dc-to-Dc Converter Employing Charge Control)

  • 임원석;최병조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1184-1186
    • /
    • 2003
  • In this paper, a charge controlled asymmetrical half-bridge (ASHB) dc-to-dc converter is presented. For ASHB do-to-dc converter, the peak current-mode control was found to be problematic primarily due to the oscillatory behavior of the current feedback signal. To resolve this problem, a charge control method is applied to the ASHB do-to-dc converter. A 50W prototype ASHB dc-to-dc converter was built, and successfully tested.

  • PDF

전하 제어 비대칭 하프 브리지 직류-직류 컨버터의 소신호 모델링과 페루프 특성 해석 (Small-Signal Modeling and Closed-Loop Analysis of Charge Control Employed to Asymmetrical Half-Bridge Dc-to-Dc Converter)

  • 임원석;차헌녕;최병조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1151-1153
    • /
    • 2004
  • In this paper, small-signal modeling and closed-loop performance of charge control employed to an asymmetrical half-bridge (ASHB) dc-to-dc converters are investigated. The charge control is selected as an alternative to the conventional voltage-mode control and peak current-mode (PCM) control, which have their respective limitations and problems when adapted to ASHB dc-to-dc converters. The current-loop dynamics of the charge control are presented in comparison with those of voltage-mode and PCM control. This paper demonstrates that the charge control offers better dynamic performance compared to voltage-mode control and superior noise characteristics compared to PCM control. The potential problem of charge control are also addressed.

  • PDF

TFT -LCD 구동 IC용 커패시터 내장형 DC-DC 변환기 설계 (A DC-DC Converter Design with Internal Capacitor for TFT-LCD Driver IC)

  • 임규호;강형근;이재형;손기성;조기석;백승면;성관영;이용진;박무훈;하판봉;김영희
    • 한국정보통신학회논문지
    • /
    • 제10권7호
    • /
    • pp.1266-1274
    • /
    • 2006
  • 본 논문에서는 TFT-LCD 구동 IC 모듈의 소형화측면에서 유리한 DC-DC 변환기 회로인 펌핑 커패시터 내장형 비중첩 부스트-클락 전하펌프 (Non-overlap Boosted-Clock Charge Pump: NBCCP) 회로가 제안되었다 .2VDC 전압으로 스윙하는 비중첩 부스트-클럭의 사용으로 기존의 펌핑 커패시터 내장형 크로스-커플드 전하펌프에 비해 펌핑 단의 수를 반으로 줄일 수 있었고, 전하 펌핑 노드의 펌핑된 전하가 입력 단으로 역류되는 현상을 방지하였다 . 그 결과 제안된 펌핑 커패시터 내장형 비중첩 부스트-클럭 전하펌프 회로는 기존의 펌핑 커패시터 내장형 크로스-커플드 전하펌프에 비해 펌핑 전류가 증가하였고, 레이아웃 면적은 감소되었다. 제안된 TFT-LCD 구동 IC용 DC-DC 변환기 회로를 $0.18{\mu}m$ Triple-Well CMOS 공정을 사용하여 설계하고, 테스트 칩을 제작 중에 있다.

Modularized Charge Equalization Converter for Hybrid Electric Vehicle Lithium-Ion Battery Stack

  • Park, Hong-Sun;Kim, Chong-Eun;Kim, Chol-Ho;Moon, Gun-Woo;Lee, Joong-Hui
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.350-352
    • /
    • 2007
  • Modularized charge equalization converter for HEV lithium-ion battery cells is proposed in this paper, in which intra-module and inter-module charge equalization can be achieved at the same time. For intra-module charge equalization, the conventional flyback DC/DC converters of low power and small size are employed, in which all of the primary sides are coupled in parallel for selective charge of the specific under charged cell within the module. For inter-module charge equalization, the flyback DC/DC converters are also added, in which all the secondary windings are electrically linked in parallel for automatic charge balancing among the modules. An engineering sample of forty cells hiring the proposed cell balancing scheme is implemented and its experimental result shows that the proposed modularized charge equalization circuit has good cell balancing performance.

  • PDF

XLPE에서 공간전하가 PD 패턴에 미치는 영향 (Effect of Space Charge on the PD Pattern in XLPE)

  • 황보승;심재위;이진종;이동영;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.96-100
    • /
    • 2001
  • We have measured the space charge distribution and PD patterns simultaneously in XLPE under AC voltages by modified PEA method in order to investigate the effect of space charge on PD patterns in XLPE with air-gap. From the experimental results, we found that the dynamic space charge accumulated on the surface of XLPE due to the PD dominantly affects the PD pattern in the dielectric-barrier structure and governs the voltage across the air-gap. Moreover, the space charge formed by applying DC voltage still remained after applying AC voltage, which means that the space charge formed during DC strength test is likely to be fatal to the long-time AC insulating characteristics of HV equipments. On the other hand, the PD patterns was much influenced by the pre-formed space charge by DC application. Therefore, it is possible to detect the effects of space charge by monitoring the infinitesimal change of PD patterns before and after DC strength.

  • PDF

A Highly Power-Efficient Single-Inductor Multiple-Outputs (SIMO) DC-DC Converter with Gate Charge Sharing Method

  • Nam, Ki-Soo;Seo, Whan-Seok;Ahn, Hyun-A;Jung, Young-Ho;Hong, Seong-Kwan;Kwon, Oh-Kyong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권5호
    • /
    • pp.549-556
    • /
    • 2014
  • This paper proposes a highly power-efficient single-inductor multiple-outputs (SIMO) DC-DC converter with a gate charge sharing method in which gate charges of output switches are shared to improve the power efficiency and to reduce the switching power loss. The proposed converter was fabricated by using a $0.18{\mu}m$ CMOS process technology with high voltage devices of 5 V. The input voltage range of the converter is from 2.8 V to 4.2 V, which is based on a single cell lithium-ion battery, and the output voltages are 1.0 V, 1.2 V, 1.8 V, 2.5 V, and 3.3 V. Using the proposed gate charge sharing method, the maximum power efficiency is measured to be 87.2% at the total output current of 450 mA. The measured power efficiency improved by 2.1% compared with that of the SIMO DC-DC converter without the proposed gate charge sharing method.

A New DC-DC Converter for Gate Driver Circuit Using Low Temperature Poly-Si TFT

  • Choi, Jin-Young;Cho, Byoung-Chul;Shim, Hyun-Sook;Kwon, Oh-Kyong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.1011-1014
    • /
    • 2004
  • In this paper, we present a new DC-DC converter for gate driver circuit in low temperature poly-Si TFT technology. It is composed of a newly developed charge pump circuit and a regulator circuit. When the input voltage is 5V, the efficiency of a positive charge pump used in the DC-DC converter and that of a negative charge pump is 69.0% and 57.1%, respectively. The output voltage of DC-DC converter varies 200mV when the target voltages of DC-DC converter are 9V, -6V and the threshold voltage of TFTs varies ${\pm}$ 0.5V.

  • PDF

DC μ-Grid 기반 배터리 충/방전 시스템의 에너지 효율에 관한 연구 (A Study on Energy Efficiency of Battery Charge/Discharge System based on DC μ-Grid)

  • 여성대;김종운;이경량;한철규;류태형;김경화;김성권
    • 한국전자통신학회논문지
    • /
    • 제10권12호
    • /
    • pp.1337-1344
    • /
    • 2015
  • Li-ion 배터리를 생산하는데 있어서 충/방전을 통한 formation 과정이 필요하다. 이 과정에서 방전기의 부하 저항을 통해 방전하게 되는데 이때 에너지 손실이 발생한다. 따라서 본 논문에서는 DC ${\mu}-Grid$ 기반의 충/방전 시스템에서 배터리를 효율적으로 운영하는 방안에 대해 연구하였다. 컴퓨터 시뮬레이션 결과, DC ${\mu}-Grid$ 기반의 충/방전 시스템에서 충전 배터리 set 3개 기준 대비 방전 배터리 set의 수가 133%를 초과하게 되면 망 전압이 안정화되는 과정에서 발생하는 전압 fluctuation 폭을 초과하기 때문에 시스템에 치명적인 손상을 야기한다. 따라서 충전 배터리 set 3개 기준 대비 방전 배터리 set의 수를 133%까지 운영할 수 있으며 획기적인 에너지 절감 효과를 확인할 수 있었다.

Charge Balance Control Methods for a Class of Fundamental Frequency Modulated Asymmetric Cascaded Multilevel Inverters

  • Babaei, Ebrahim
    • Journal of Power Electronics
    • /
    • 제11권6호
    • /
    • pp.811-818
    • /
    • 2011
  • Modulation strategies for multilevel inverters have typically focused on synthesizing a desired set of sinusoidal voltage waveforms using a fixed number of dc voltage sources. This makes the average power drawn from different dc voltage sources unequal and time varying. Therefore, the dc voltage sources are unregulated and require that corrective control action be incorporated. In this paper, first two new selections are proposed for determining the dc voltage sources values for asymmetric cascaded multilevel inverters. Then two modulation strategies are proposed for the dc power balancing of these types of multilevel inverters. Using the charge balance control methods, the power drawn from all of the dc sources are balanced except for the dc source used in the first H-bridge. The proposed control methods are validated by simulation and experimental results on a single-phase 21-level inverter.

Behavior of Residual Charges in Water-tree Degraded XLPE Sheets and Cable

  • Ebinuma, Yasumitsu;Masui, Noriaki
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권5호
    • /
    • pp.224-229
    • /
    • 2006
  • Many studies have been done on the application of residual charge measurement in cable degradation diagnosis. In this paper, the behavior of residual charges measured with water-tree degraded XLPE sheets and cable are discussed. At charge injection process, the charge is injected by applying dc voltage as a conventional method, suddenly cut-off ac voltage or impulse voltage. Therefore the residual charge is influenced by the applying process. At charge release process, transient dc current flows when applying ac high voltage and also ac high voltage superimposed to dc low voltage. From the results, new diagnosis method is suggested.