• 제목/요약/키워드: DC bus

검색결과 271건 처리시간 0.027초

$S^4$-PFC에서 커플링 인덕터를 이용하여 DC 버스 스트레스를 저감시킨 AC/DC 컨버터 ($S^4$-PFC AC/DC Converter To Reduce DC Bus Stress With Coupling Inductor)

  • 이장현;김태웅;이성백
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2515-2517
    • /
    • 1999
  • In this paper we analysis DC bus voltage stress at high line voltage and light load in $S^4$-PFC Isolated AC/DC converter with DC bus voltage feedback using coupling in transformer. In this converter, the principle of operation and the practical problems in the design are considered. Simulation and experimental results are presented to verify the operation and performance of the $S^4$-PFC converter with DC bus voltage feedback. Experimental sets are performed in the conditions; switching frequency 100 kHz, output of 5 V, 60W, and universal line input voltage.

  • PDF

dc bus 중심 제어를 이용한 UPS 기능을 갖는 단상 태양광 발전 시스템 (Single-Phase PCS with UPS Function Based on Dc Bus Oriented Control)

  • 김응호;권정민;권봉환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.293-296
    • /
    • 2007
  • 본 논문에서는 UPS 기능을 갖는 단상 태양광 발전 시스템을 제안하였다. 제안하는 시스템은 태양광 어레이 (photovoltaic array)에서 최대전력을 얻기 위해 MPPT (maximum power point tracking)를 수행하는 컨버터, 계통전원 상태나 태양광 발전량에 상관없이 부하에 정현파 전압을 공급하는 인버터, 태양광 어레이에서 발전된 잉여전력을 계통으로 전달하거나 부하에 필요한 전력을 dc bus로 공급하는 인버터, 정전시 dc bus에 전력을 공급하는 양방향 컨버터 (bidirectional converter)로 구성된다. 제안하는 시스템은 발전된 전력을 계통으로 전달할 뿐만 아니라, UPS (uninterruptible power supply)기능도 수행하는 시스템으로 계통전압이 불안정하거나 정전시에도 부하에 안정적이고 깨끗한 전압을 항상 공급할 수 있다. 각각의 인버터, 컨버터, 및 양방향 컨버터는 dc bus를 공유하며, dc bus의 전압에 따라 동작상태가 결정이 된다. dc bus중심의 제어는 dc bus전압을 안정적으로 유지시키며, 부하에 걸리는 전압의 변동을 최소로 하고 시스템의 디자인 및 제어를 단순화한다. 모든 알고리즘과 제어기를 하나의 마이크로 컨트롤러로 구현하였고 제안된 시스템의 우수성을 실험을 통해 검증하였다.

  • PDF

병렬 부하를 갖는 DC배전 시스템을 위한 Voltage Bus Conditioner의 향상된 적응제어 (An improved adaptive control technique for the Voltage Bus Conditioner with parallel loads in the DC Power Distribution System)

  • 이병헌;장한솔;나재두;김영석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.249-250
    • /
    • 2011
  • In DC Power Distribution System(DC PDS), a bus voltage instability is occurred by multiple parallel loads. The Voltage Bus Conditioner(VBC) is used to mitigate the DC bus voltage transient. An adaptive controller of the VBC is designed and the simulation result of the controller is verified by PSIM simulation package for the proposed control technique.

  • PDF

PCB DC Power-Bus로부터의 전파 방사에 관한 연구 (A Study on the Radiated Emission from the DC Power-Bus for the PCB)

  • 강승택
    • 한국전자파학회논문지
    • /
    • 제17권2호
    • /
    • pp.148-151
    • /
    • 2006
  • PCB에서의 전자파 간섭원으로 DC power-bus의 공진이 자주 지목된다. 이것은 결국, 전도성 또는 전파 방사의 형태로, 하나 또는 인접한 시스템에서 디지털 SI를 저하시키게 된다. 따라서 PCB의 방사 문제를 파악하는 것은 중요하므로, 본 논문은 DC power-bus 공진 모드에 대한 방사를 면밀히 살펴본다. 엄밀한 주파수 영역 해석법을 이용하여 임피던스와 방사 전계를 구하고, 이는 물리와 전자파 해석 모의시험에 의해 타당성이 검토된다.

DC 배전시스템에서 Voltage Bus Conditioner를 위한 PI 보상기 설계 (The Design of the PI Compensator for a Voltage Bus Conditioner in the DC Distributed Power System)

  • 김영석;석봉준;나재두
    • 전기학회논문지
    • /
    • 제59권12호
    • /
    • pp.2195-2201
    • /
    • 2010
  • The VBC(Voltage Bus Conditioner) is a bidirectional DC-DC converter with the energy storage for damping the instability and any transients of bus voltage in the DC DPS(Distributed Power System). This paper presents the PI(Proportional Integration) controller for the VBC. The PI controller is not only damping the bus transient, but also keeping the storage voltage level. Matlab Simulink simulation and experimental results are presented by validity of the proposed control technique.

DC Bus Conditioner을 위한 카변히스테리시스제어 (A Variable Hysteresis Control for a DC Bus Conditioner)

  • 라재두;한문섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.472-475
    • /
    • 2008
  • A DC distributed power system(DPS) has many loads with varied functions. In particular, there may be large pulsed toads with short duty ratio, which can affect the normal operation of other loads. In this paper, a bi-directional converts with inductive storage is used as a DC bus conditioner to damp voltage transients on the bus. In addition, the constant frequency hysteresis control technique for a DC bus conditioner is presented. A simple and fast prediction of the hysteresis band-width is implemented by the phase-lock loop control, keeping constant switching frequency. This technique offers the excellent dynamic response in load or parameter variation. The control performance is illustrated by simulated results with the SABER package. The proposed hysteresis control results in the shortest and the smallest excursions.

  • PDF

A Novel DC Bus Voltage Balancing of Cascaded H-Bridge Converters in D-SSSC Application

  • Saradarzadeh, Mehdi;Farhangi, Shahrokh;Schanen, Jean-Luc;Frey, David;Jeannin, Pierre-Olivier
    • Journal of Power Electronics
    • /
    • 제12권4호
    • /
    • pp.567-577
    • /
    • 2012
  • This paper introduces a new scheme to balance the DC bus voltages of a cascaded H-bridge converter which is used as a Distribution Static Synchronous Series Compensator (D-SSSC) in electrical distribution network. The aim of D-SSSC is to control the power flow between two feeders from different substations. As a result of different cell losses and capacitors tolerance the cells DC bus voltage can deviate from their reference values. In the proposed scheme, by individually modifying the reference PWM signal for each cell, an effective balancing procedure is derived. The new balancing procedure needs only the line current sign and is independent of the main control strategy, which controls the total DC bus voltages of cascaded H-bridge. The effect of modulation index variation on the capacitor voltage is analytically derived for the proposed strategy. The proposed method takes advantages of phase shift carrier based modulation and can be applied for a cascaded H-bridge with any number of cells. Also the system is immune to loss of one cell and the presented procedure can keep balancing between the remaining cells. Simulation studies and experimental results validate the effectiveness of the proposed method in the balancing of DC bus voltages.

A Design of a PI Compensator for a Bidirectional DC-DC Converter in a DC Distributed Power System

  • Lee, Joonmin;Seok, Bong Jun;La, Jae Du;Kim, Young Seok
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권3호
    • /
    • pp.391-396
    • /
    • 2012
  • The Voltage Bus Conditioner(VBC) is a bidirectional DC-DC converter for damping the instability and any transients of the bus voltage in a DC Distributed Power System(DPS). In this paper, a PI controller for the VBC has been designed for the frequency domain. The proposed PI controller not only dampens the bus transients, but also keeps the storage voltage level. Simulation by Matlab/Simulink and experimental results are presented for the validity of the proposed control technique.

Zigbee통신을 이용한 전력변환기기의 DC Bus 커패시터의 온라인 원격 고장진단 시스템 (On-line Remote Diagnosis System for DC Bus Capacitor of Power Converters Using Zigbee Communication)

  • 정완섭;손진근
    • 전기학회논문지P
    • /
    • 제64권1호
    • /
    • pp.29-34
    • /
    • 2015
  • DC bus electrolytic capacitors are used in variety of equipments as smoothing element of the power converters because it has high capacitance for its size and low price. It is responsible for frequent breakdowns of many static converters and inverter drive systems. Therefore it is important to diagnosis monitoring the condition of an electrolytic capacitor in real-time to predict the failure of power converter. In this paper, the on-line remote diagnosis monitoring system for DC BUS electrolytic capacitors of power converter using low-cost type Zigbee communication modules is developed. To estimate the health status of the capacitor, the equivalent series resistor(ESR) of the component has to be determined. The capacitor ESR is estimated by using RMS computation using AC coupling method of DC link ripple voltage/current. The Zigbee communication-based experimental results show that the proposed remote DC capacitor diagnosis monitoring system can be applied to DC/DC converter and UPS successfully.

Study on the Effect of Metal-Wall Loading on the DC Power-Bus

  • Kahng Sungtek
    • Journal of electromagnetic engineering and science
    • /
    • 제5권4호
    • /
    • pp.193-196
    • /
    • 2005
  • The DC power-bus for the PCB is loaded with metal walls on its selected sides and is characterized electromagnetically. This is a novel concept of approach to mitigate the spurious resonance and finally signal integrity problems. In particular, the peak at DC, which is always in the way to secure parallel-plates' EMC, can be completely removed by the proposed method. Through the findings of this study, the effect of metal-loading of the power-bus will be presented along with the impression that the suggested technique can tackle the headaches of signal integrity, ground bounce, EMIs.