• 제목/요약/키워드: DC breaker

검색결과 100건 처리시간 0.028초

태양광 발전이 연계된 DC 마이크로 그리드의 시뮬레이션 (Simulation of DC Microgrid with PV Generation)

  • 박철원
    • 전기학회논문지P
    • /
    • 제66권4호
    • /
    • pp.267-273
    • /
    • 2017
  • In recent years, there is an increasing demand for DC microgrid because the digital load due to DC increases and the efficiency of the distribution system increases due to loss of conversion losses and conversion stages due to reactive power compared to AC distribution. Currently, with the support of the KEPRI, the development of an electronic large-capacity circuit breaker for DC distribution protection, which has been underway since 2016, is proceeding. In this paper, as a part of this project, we modeled the DC microgrid connected with PV using PSCAD. The converter station, AC/DC converter control, PV and MPPT controller are designed. In order to evaluate the performance of the modeled DC microgrid, it is examined whether the voltage is adjusted according to the load variation.

전기철도 변전소의 직류고속도차단기 동작 감소방안에 관한 연구 (A Study on the DC High Speed Circuit Breaker(HSCB) in Electric Railway Substation System)

  • 허태복;김학련;창상훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1303-1308
    • /
    • 2004
  • This paper proposes a reduction method for the mis-operation analysis of the DC High Speed Circuit Breaker(HSCB) in electric railway substation system. The analysis method is based on present condition of operation which is a method for accuracy level up. There is reason to operation of HSCB that it is mis-operation of fault detection relay(50F), operation of ground fault relay(64P), and trouble of electric car. A countermeasure is relay resetting through field test, induction of GTOCB(Gate Turn Off Thyristor Circuit Breaker), HSVCB(High Speed Vacuum Circuit Breaker), coordination with electric car. The results presented in the paper can be used as a reference for maintenance free in electric railway substation system.

  • PDF

DC 차단기의 하이브리드 아크 소호 기법에 관한 연구 (A Study on the Hybrid Arc Extinguishing Mechanism of the DC Circuit Breaker)

  • 주남규;김남호
    • 한국항행학회논문지
    • /
    • 제19권3호
    • /
    • pp.250-256
    • /
    • 2015
  • 손쉬운 제어성, 운용성 등 다양한 이유로 디지털 부하가 급증하고 있고 이와 함께 부하의 소비 패턴은 직류화 되고 있다. 그러나 공급되는 전력은 교류 전원이므로 실질적으로 필요로 하는 부하의 공급 전원인 직류 전원을 만족하기 위하여 교류 전원을 다시 직류로 변환하여 사용하고 있다. 태양광, 풍력, 연료전지 등 신재생 에너지원의 경우 직류 발전을 하는 발전원으로 교류로 변환을 통해 계통에 유입되고 다시 직류로 변환되어 부하에 공급하게 되는 다단 변환을 하게 되어 손실은 지속적으로 증가하게 된다. 에너지원의 효율적인 사용을 위한 직류 기반의 배전 시스템이 필요로 하나, 부하뿐만 아니라 보호 기능을 구현하기 위한 직류 배선용 차단기의 개발이 필요하다. 이에 본 연구에서는 영구 자석을 이용한 아크 소호 기술과 하이브리드 아크 소호 기술을 이용한 직류 아크 소호 기술에 대한 연구를 통하여 안정적인 직류 배전 시스템 운용을 위한 계통 및 기기 보호가 가능할 것으로 기대된다.

전기철도 교/직 절연구분장치의 절연열화 현상 (Insulation Deterioration of AC/DC Section Insulators for Electric Railroad Catenary.)

  • 최규형
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권1호
    • /
    • pp.16-22
    • /
    • 2003
  • While passing through the AC/DC section insulators installed at electric railroad catenary, some electric trains undergo mis-operation of main circuit breaker after AC/DC change-over operation. This paper provides insulation resistance measurements of AC/DC section insulators, which confirm the insulation levels of section insulators are below the standard of insulators. The insulation deterioration and pantograph arrangement on the electric train can produce voltage impression on section insulator which induces mis-operation of main circuit breaker To mitigate the insulation deterioration of the section insulator installed at underground railroads, the section insulators have been cleaned periodically, but section insulator structure should be modified to make the section insulator performance perfect. Based on the above analysis, effective modification method of AC/DC section insulator is provided.

Z-source 직류 차단기의 기계식 스위치 적용을 위한 최적화 설계 (Optimization Design for the Use of Mechanical Switch in Z-source DC Circuit Breaker)

  • 이현승;이건아
    • 한국안전학회지
    • /
    • 제37권1호
    • /
    • pp.12-19
    • /
    • 2022
  • Circuit breakers are a crucial factor in ensuring the safety of a Direct Current (DC) grid. One type of DC circuit breaker, the Z-source DC circuit breaker (ZCB), uses a thyristor, which is a type of semiconductor switch. In the event of a fault in the circuit, the ZCB isolates the fault by generating a zero crossing current in the thyristor. The thyristor quickly and actively isolates the fault while generating a zero crossing current, but thyristor switch cannot control turn-off and the allowable current is lower than the current of the mechanical switch. Therefore, it is best to use a mechanical switch with a high allowable current capacity that is capable of on/off control. Due to the slow reaction time of mechanical switches, they may not isolate the fault during the zero crossing current time interval created by the existing circuit. In this case, the zero crossing current time can be increased by using the property that hinders the rapid change in the current of the inductor. This paper will explore whether adding system inductance to increase the zero crossing current time interval is a solution to this problem. The simulation of changing inductor and capacitor (LC) of the circuit is repeated to find an optimal change in the zero crossing current time according to the LC change and provides an inductor and capacitor range optimized for a specific load. The inductor and capacitor range are expected to provide optimization information in the form LC values for future applications of ZCB's using a mechanical switch.

개극시간 조정회로를 삽입한 축소형 가스절연 차단기 (Compact Gas-Insulated Circuit-Breaker adopting opening-time control circuits)

  • 김정배;김두성;서경보;양대일;송원표;김맹현;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.485-487
    • /
    • 2004
  • High-voltage gas-insulated circuit-breaker must interrupt short-circuit current successfully when breakdown occurs in electric power system. Among many test-duties, Basic Terminal fault T100a(BTF T100a) is the one of the severest duties because of its high DC component of short-circuit current. In this paper, we developed 245kV 50kA gas circuit breaker using control circuits to reduce DC component while interrupting short-circuit current, then got good performance through high-power tests in Korea Electrotechnology Research Institute(KERI) and KEMA

  • PDF

노후전력설비 교체에 따른 SCADA시스템의 운용 고찰 (Exchanging of old electrical equipment and discussion of SCADA system's operation related with exchanging of old electrical equipment)

  • 김윤식;박래혁;이기승
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.417-422
    • /
    • 2008
  • The DC high speed circuit breaker used in Seoul Metro for line no.1.2 is Japan HITACHI and FUJI breaker, and for line no.3.4 is Whipp & Bourne MM74 breaker from UK. The years that each breakers made are 1973(line no.1), 1984(line no.3.4), So that equipments are superannuated. Nowday the for equipment exchanging is executing, equipment for exchanging were used the Secheron breaker from Swiss. but now the Intec breaker made in Korea is used. The RTU of supervisory control and data acquisition system have the capabilities that can observe, control and work the installation efficiently. In this paper, as summarizing the solving process of problem that happened the SCADA system when old-equipment exchange and concerned point for logical supervision and control of reservation factors and equipment, I'll provide the direction that can do receiving-process of control-equipment, progressed with the exchange of old-electronic equipment.

  • PDF

지하철 변전소용 GTO 싸이리스터 차단기 개발 (The Development of GTO circuit breaker for subway substation)

  • 윤재학;최세경;정명길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.524-526
    • /
    • 1997
  • High speed DC circuit breakers (HSCB) are indispensable for protection of DC electric subway substations from fault current. However, the HSCB has mechanical contact to wear, which requires rather frequent maintenance, we have succeeded in developing and manufacturing a GTO DC circuit breaker using GTOs and ZnO varistors. In this paper, we describes the outline of the system itself, its characteristics and test data.

  • PDF

FPGA를 활용한 DC계통 고장진단에 관한 연구 (A Study on fault diagnosis of DC transmission line using FPGA)

  • 김태훈;채준수;이승윤;안병현;박재덕;박태식
    • 전기전자학회논문지
    • /
    • 제27권4호
    • /
    • pp.601-609
    • /
    • 2023
  • 본 논문에서는 DC 계통의 지락고장시 고속 고장진단을 위해 FPGA를 이용한 인공지능기반 고장진단 방법을 제안한다. 인공지능 알고리즘을 고장진단에 적용시 많은 연산량과 대용량의 실시간 데이터 처리가 요구된다. 또한 DC 계통에서의 고장 및 사고는 고장 전류의 빠른 상승률로 인하여 DC 차단기가 고속 차단능력이 필요하다. 인공지능기반 고속 고장진단이 가능한 FPGA를 사용하여 DC 차단기가 더 빠르게 동작함으로써, DC 차단기의 차단용량을 줄일 수 있다. 따라서 본 논문에서는 Matlab Simulink를 이용하여 DC계통의 고장 모의를 통해 고장데이터를 수집하여 지능형 고속 진단 알고리즘 구현하였으며, FPGA에 지능형 고속고장 진단 알고리즘을 적용 및 성능검증을 하였다.

재투입과 재차단의 기능을 갖는 새로운 DC SSCB (A Novel DC Solid State Circuit Breaker with Rebreaking and Reclosing Capability)

  • 김진영;최승수;김인동
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.518-519
    • /
    • 2015
  • 전력효율을 높일 수 있는 DC 전송이 주요 관심사가 됨에 따라 전력품질에 대한 기술이 요구된다. DC 그리드의 전력품질을 위해서는 반도체 차단기는 필수요소이다. 따라서 본 연구에서는 신속한 차단이 가능하고 재투입과 재차단 기능을 갖는 반도체 차단기를 제안한다. 제안한 회로는 단락 사고를 모의하고 시뮬레이션과 실험을 통해 시스템의 동작 특성을 검증하였다.

  • PDF