• 제목/요약/키워드: DC Output Filter

검색결과 194건 처리시간 0.029초

UPS용 병렬공진형 직류링크인버터를 위한 제어방식에 관한 연구 (Control Strategy of Resonant DC Link Inverter for UPS)

  • 백주원;유동욱;민병권;류승표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.159-161
    • /
    • 1994
  • A new control technique which generates high-quality sinusoidal output voltage from a single-phase resonant do link inverter suitable for the UPS systems is presented. The inverter output voltage control system has the PID controller with a minor loop of the filter inductor current and tile feedforward controller. The proposed control scheme also solves resonant voltage overshoot without any additional switch or passive component, resulting in pulses with uniform amplitude and high efficiency. Experimental results in the case of linear and nonlinear loads are presented to confirm the usefulness of the Proposed control algorithms.

  • PDF

전류센서리스 단위역률 3상 PWM AC/DC Boost 컨버터 (Current Sensorless Three Phase PWM AC/DC Boost Converter with Unity Power Factor)

  • 천창근;김철우
    • 조명전기설비학회논문지
    • /
    • 제17권6호
    • /
    • pp.105-112
    • /
    • 2003
  • AC/DC 전력변환장치로서 위상제어 컨버터나 출력전압을 제어할 수 없는 다이오드 정류기는 역률저하 및 저차고조파 발생의 문제점을 가진다. 본 논문에서는 역률개선 및 고조파 감소의 문제점을 극복하기 위하여 3상 PWM AC/DC Boost 컨버터에 대해 연구하였다. 제안한 컨버터의 특성은 입력 단에 전류 센서 없이 전압 센서만을 사용하여 입력전류의 위상을 조정하는 비교적 간단한 알고리즘으로 단위역률을 구현하였으며, 일정 주파수로 스위칭 소자를 구동시키는 정현 PWM 방식을 채용하여 불규칙한 스위칭 주파수 방식에서 나타나는 입력필터의 설계 및 스위칭 소자 선정에 대한 어려움을 극복하였다. 본 논문에서 제안한 제어알고리즘을 시뮬레이션 한 결과 부하영역 및 발전영역에서도 단위역률이 잘 이루어졌으며 DC link 단의 출력전압이 거의 리플 없이 다이나믹한 응답특성을 보였다. 또 시뮬레이션으로 얻어진 회로정수를 바탕으로 인덕터 및 커패시터의 용량을 적절한 크기로 산정하여 실험 에 적용한 결과 같은 부하조건에서 다이오드 정류기와 비교하여 역률 및 저차 고조파가 현저하게 개선되었음을 알 수 있었다.

IGBT Open-Circuit Fault Diagnosis for 3-Phase 4-Wire 3-Level Active Power Filters based on Voltage Error Correlation

  • Wang, Ke;Tang, Yi;Zhang, Xiao;Wang, Yang;Zhang, Chuan-Jin;Zhang, Hui
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1950-1963
    • /
    • 2016
  • A novel open-circuit fault diagnosis method for 3-phase 4-wire 3-level active power filters based on voltage error correlation is proposed in this paper. This method is based on observing the output pole voltage error of the active power filter through two kinds of algorithms. One algorithm is a voltage error analytical algorithm, which derives four output voltage error analytic expressions through the pulse state, current value and dc bus voltage, respectively, assuming that all of the IGBTs of a certain phase come to an OC fault. The other algorithm is a current circuit equation algorithm, which calculates the real-time output voltage error through basic circuit theory. A correlation is introduced to measure the similarity of the output voltage errors between the two algorithms, and OC faults are located by the maximum of the correlations. A FPGA has been chosen to implement the proposed method due to its fast prototyping. Simulation and experimental results are presented to show the performance of the proposed OC fault diagnosis method.

ZCS를 이용한 고주파 공진형 상용주파수 전원에 관한 연구 (A Study on Commercial Frequency Source with High Frequency Resonant Type using ZCS)

  • 김종해;김동희;노채균;구태근;배상준;이봉섭
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권8호
    • /
    • pp.448-454
    • /
    • 1999
  • This paper describes a new dc-ac inverter system which for achieving sinusoidal ac waveform makes use of parallel loaded high frequency resonant inverter consisting of full bridge. Each one of the pair of switches in the inverter is driven to synchronous output frequency and the other is driven to PWM signal with resonant frequency proportional to magnitude of sine wave. A forced discontinuous conduction mode is used to realize the quasi-sinusoidal pulse in each switching period. Therefore the inverter generates sinusoidal modulated output voltage including carrier frequency that is resonant frequency. Carrier frequency components of modulated output voltage is filtered by low pass filter. Since current through switches is always zero at its turn-on in the proposed inverter, low stress and low switching loss is achieved. Operating characteristics of the proposed system is analyzed in per unit system using computer simulation. The output voltage of if includes low harmonics and it is almost close to sine wave. Also, the theoretical analysis is proved through the experimental test.

  • PDF

독립형 풍력발전용 PWM 인버터의 출력전압의 비선형 제어 (Nonlinear Control of Output Voltages of PWM Inverters for Stand-Alone Wind Power Generation)

  • 장정익;구성영;이동춘
    • 전력전자학회논문지
    • /
    • 제12권2호
    • /
    • pp.131-138
    • /
    • 2007
  • 본 논문은 출력단에 LC필터를 갖는 3상 PWM 인버터의 출력전압을 일정전압/일정주파수로 제어하기 위한 새로운 비선형 제어기법을 제안한다. 출력 LC필터를 포함한 비선형 모델을 궤환선형화(feedback linearization) 이론을 통하여 선형화하고 선형 제어이론에 기초하여 제어기를 설계한다. 이 제어기는 LC 출력필터를 갖는 PWM 인버터를 사용하는 독립형 풍력발전 시스템에 적용된다. 제안한 제어기법은 정상상태와 부하변동의 과도상태에 대한 실험을 통하여 검증된다.

Improvement of LCC-HVDC Input-Output Characteristics using a VSC-MMC Structure

  • Kim, Soo-Yeon;Park, Seong-Mi;Park, Sung-Jun;Kim, Chun-Sung
    • 한국산업융합학회 논문집
    • /
    • 제24권4_1호
    • /
    • pp.377-385
    • /
    • 2021
  • High voltage direct current(HVDC) systems has been an alternative method of a power transmission to replace high voltage alternate current(HVAC), which is a traditional AC transmission method. Due to technical limitations, Line commutate converter HVDC(LCC-HVDC) was mainly used. However, result from many structural problems of LCC-HVDC, the voltage source converter HVDC(VSC-HVDC) are studied and applied recently. In this paper, after analyzing the reactive power and output voltage ripple, which are the main problems of LCC-HVDC, the characteristics of each HVDC are summarized. Based on this result, a new LCC-HVDC structure is proposed by combining LCC-HVDC with the MMC structure, which is a representative VSC-HVDC topology. The proposed structure generates lower reactive power than the conventional method, and greatly reduces the 12th harmonic, a major component of output voltage ripple. In addition, it can be easily applied to the already installed LCC-HVDC. When the proposed method is applied, the control of the reactive power compensator becomes unnecessary, and there is an advantage that the cut-off frequency of the output DC filter can be designed smaller. The validity of the proposed LCC-HVDC is verified through simulation and experiments.

Cost-Effective APF/UPS System with Seamless Mode Transfer

  • Lee, Woo-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.195-204
    • /
    • 2015
  • In this paper, the development of a cost-effective active power filter/uninterruptible power supply (APF/UPS) system with seamless mode transfer is described. The proposed scheme employs a pulse-width-modulation (PWM) voltage-source inverter and has two operational modes. First, when the source voltage is normal, the system operates as an APF, which compensates for the harmonics and power factor while boosting the DC-link voltage to be ready for the disturbance, without an additional DC charging circuit. A simple algorithm to detect the load current harmonics is also proposed. Second, when the source voltage is out of the normal range (owing to sag, swell, or outage), it operates a UPS, which controls the output voltage constantly by discharging the DC-link capacitor. Furthermore, a seamless transfer method for the single-phase inverter between the APF mode and the UPS mode is also proposed, in which an IGBT switch with diodes is used as a static bypass switch. Dissimilar to a conventional SCR switch, the IGBT switch can implement a seamless mode transfer. During the UPS operation, when the source voltage returns to the normal range, the system operates as an APF. The proposed system has good transient and steady-state response characteristics. The APF, charging circuit, and UPS systems are implemented in one inverter system. Finally, the validity of the proposed scheme is investigated with simulated and experimental results for a prototype APF/UPS system rated at 3 kVA.

QZSI를 이용한 계통연계형 태양광발전 시스템의 직류단 전압제어 (DC-link Voltage Control of Grid Connected PV System using Quasi Z-Source Inverter)

  • 박종형;김흥근;노의철;전태원;차헌녕
    • 전력전자학회논문지
    • /
    • 제19권3호
    • /
    • pp.201-210
    • /
    • 2014
  • In this paper, dc-link voltage control of a grid-connected QZSI is presented. Since the input current of the ZSI is discontinuous, a capacity with relatively large capacitance should be connected to the output of the PV array in order to reduce the current ripple. Due to the presence of the impedance network inductor in series with the PV array, the QZSI can achieve continuous input current flow. Several dc-link voltage control methods are compared and the method for power quality improvement is also presented. The performance of the proposed method is verified through both simulation and experimental results.

5-Gb/s 연속시간 적응형 등화기 설계 (A 5-Gb/s Continuous-Time Adaptive Equalizer)

  • 김태호;김상호;강진구
    • 전기전자학회논문지
    • /
    • 제14권1호
    • /
    • pp.33-39
    • /
    • 2010
  • 본 논문에서는 5Gb/s의 직렬 링크 인터페이스에 적용 가능한 적응형 수신기를 제안한다. 효율적인 이득 제어를 위해 등화필터의 출력단 대신 슬라이서의 내부 신호를 적용한 LMS(Least Mean Square) 알고리즘을 구현하였다. 제안된 방식은 등화기의 대역폭에 영향을 미치지 않는다. 또한 비슷한 DC 크기의 신호를 가지는 슬라이서(slicer)의 내부 신호를 이용하였기 때문에 수동소자를 이용한 필터를 제거함으로써 칩 면적 및 전력소모를 줄일 수 있다. 제안된 적응형 등화기는 25dB까지 보상이 가능하며 디스플레이포트를 위한 15-m STP 케이블과 FR-4 전송선로에 적용 가능하다. 제안된 회로는 $0.18{\mu}m$ 1-폴리 4-메탈 CMOS 공정 기술이 적용하여 구현하였으며 $200{\times}300{\mu}m^2$의 칩 면적을 차지한다. 제작된 칩의 측정 결과 1.8V 공급전원에서 6mW의 매우 적은 전력소모를 나타내고 2Gbps 동작을 확인하였다. 안정된 RF용 버랙터(Varactor)를 사용하는 공정을 적용할 경우 5Gbps 동작범위를 만족할 것으로 예상된다.

A Biomolecular Sensing Platform Using RF Active System

  • Kim, Sang-Gyu;Lee, Hee-Jo;Yook, Jong-Gwan
    • Journal of electromagnetic engineering and science
    • /
    • 제12권4호
    • /
    • pp.227-233
    • /
    • 2012
  • This paper describes a novel and compact biosensing platform using an RF active system. The proposed sensing system is based on the oscillation frequency deviation due to the biomolecular binding mechanism on a resonator. The impedance variation of the resonator, which is caused by a specific biomolecular interaction results in a corresponding change in the oscillation frequency of the oscillator so that this change is used for the discrimination of the biomolecular binding, along with concentration variation. Also, a Surface Acoustic Wave (SAW) filter is utilized in order to enhance the biosensing performance of our system. Because the oscillator operates at the skirt frequency range of the SAW filter, a small amount of oscillation frequency deviation is transformed into a large variation in the output amplitude. Next, a power detector is used to detect the amplitude variation and convert it to DC voltage. It was also found that the frequency response of the biosensing system changes linearly with three streptavidin concentrations. Therefore, we expect that the proposed RF biosensing system can be applied to bio/medical applications capable of detecting a nano-sized biomolecular interaction.