Design and Implementation of an ESS for Efficient Power Management of Stand-Alone Type Street Lights (효율적 전력 관리를 위한 독립형 가로등의 ESS 설계 및 구현)

  • Kang, Jingu
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.12 no.2
    • /
    • pp.1-6
    • /
    • 2016
  • Several efforts to replace the use of existing fossil energy resources have already been made around the world. As a result, a new industry of renewable energy has been created, and efficient energy distribution and storage has been promoted intensively. Among the newly explored renewable energy sources, the most widely used one is solar energy generation, which has a high market potential. An energy storage system (ESS) is a system as required. In this paper, the design and implementation of an ESS for the efficient use of power in stand-alone street lights is presented. In current ESS applied to stand-alone street lights, either 12V~24V DC (from solar power) or 110V~220V AC (from commercial power) is used to recharge power in systems with lithium batteries. In this study, an ESS that can support both solar power and commercial power was designed and implemented; it can also perform emergency recharge of portable devices from solar powered street lights. This system can maximize the scalability of ESSes using lithium batteries with efficient energy conversion, with the advantage of being an eco-friendly technology. In a ripple effect, it can also be applied to smart grids, electric vehicles, and new, renewable storage markets where energy storage technology is required.

Rotor Position Detection of CPPM Belt Starter Generator with Trapezoidal Back EMF using Six Hall Sensors

  • Xu, Jiaqun;Long, Feng;Cui, Haotian
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.173-178
    • /
    • 2016
  • Six-step commutation control widely used in brushless DC (BLDC) motor can be applied to consequent pole permanent magnet (CPPM) belt starter generator (BSG) with trapezoidal back electromotive force (EMF) in the starter state. However, rotor position detection with three Hall sensors in BLDC motor can hardly be employed in CPPM BSG due to asymmetric flux distribution in each pole side of CPPM BSG. This paper presents a low-cost rotor position detection method for CPPM BSG in which six Hall sensors are proposed to be used based on the analysis of flux distribution by 3D FEA. In the method, the six Hall sensors are divided into three groups and two signals in each group are combined through performing logic operations. In addition, offset angle between back EMF and the related Hall signal can be compensated by moving the Hall sensors. Experiments of a 2 kW CPPM BSG prototype have also been performed to verify the proposed method.

Aging Diagnosis of Underground Distribution Power Cables by Isothermal Relaxation Current Measurement Equipment (완화전류 측정에 의한 지중배전케이블의 열화진단)

  • Kim, Ju-Yong;Song, Il-Keun;Kim, Dong-Myung;Yun, Tae-Sang;Jeong, Sang-Bong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.502-505
    • /
    • 2004
  • The purpose of this experiment is to modify diagnosis criterion of isothermal relaxation current(IRC) measurement equipment which is using for distribution cable diagnosis. We're using this system for several years in the field instead of DC leakage current measurement and lots of cables were replaced. But we have to investigate on the reliability of this equipment for our cables because we didn't carried out condition assessment of extracted cables after field diagnosis by this equipment. It is important thing for cable maintenance. If the replacement criterion is improper we can not prevent failures or will waste budget on account of replacement of the sound cables. In this papar we selected field installed cables and injected silicone fluid to the cables for insulation rehabilitation. In order to prove reliability of the diagnosis equipment we compared diagnosis results and AC breakdown strength according to operating time after silicone treatment. This is the results of the field test for 1 year.

  • PDF

Aging Diagnosis and Characteristic Analysis of Distribution ,Power Cables I to Prepare Optimal Replacement Criterion (지중 배전케이블의 최적 교체기준 수립을 위한 열화진단 및 특성분석)

  • 김주용;송일근;정익중;한명관;심유종;문재덕
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.5
    • /
    • pp.258-263
    • /
    • 2004
  • The purpose of this experiment is to modify diagnosis criterion of isothermal relaxation current(IRC) measurement equipment which is using for distribution cable diagnosis. We're using this system for several years in the field instead of DC leakage current measurement and lots of cables were replaced. But we have to investigate on the reliability of this equipment for our cables because we didn't carried out condition assessment of extracted cables after field diagnosis by this equipment. It is important thing for cable maintenance. If the replacement criterion is improper we can not prevent failures or will waste budget on account of replacement of the sound cables. In this paper we selected field installed cables and injected silicone fluid to the cables for insulation rehabilitation. In order to prove reliability of the diagnosis equipment we compared diagnosis results and AC breakdown strength according to operating time after silicone treatment. This is the results of the field test for 1 year.

Isolated Bidirectional CLLC Resonant Converter using Digital Control for LVDC Distribution System (디지털로 제어되는 저압 직류 배전용 절연형 양방향 CLLC 공진형 컨버터)

  • Jung, Jee-Hoon;Kim, Ho-Sung;Ryu, Myung-Hyo;Kim, Jong-Hyun;Kim, Tae-Jin;Baek, Ju-Won
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.379-380
    • /
    • 2012
  • A bidirectional full-bridge CLLC resonant converter using a digital control method is proposed for a LVDC power distribution system. This converter can operate under high power conversion efficiency since the CLLC resonant network has soft switching capability for primary switches and output rectifiers. In addition, the power conversion efficiency of any directions is exactly the same as each other because of the symmetric structure of the converter. Intelligent digital control methods are proposed to regulate output voltage under any power flow directions. A 5kW prototype converter was designed for a high-frequency galvanic isolation of 380V dc buses using a digital signal processor to verify the performance of the proposed topology and algorithms.

  • PDF

Experimental Study on Electrical Agglomeration of Liquid Particles in an Alternating Electric Field (AC 전기장내 하전 액체 입자의 응집에 관한 실험적 연구)

  • Ji, Jun-Ho;Hwang, Jung-Ho;Bae, Gwi-Nam;Kim, Yong-Gin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.3
    • /
    • pp.442-450
    • /
    • 2001
  • Experiments were carried out on agglomeration of bipolarly charged particles in an alternating current electric field. Laboratory-scale setup was built and experiments were conducted at atmospheric condition. DOS(Di-octyl Sebacate) particles with 100% purity were generated by an atomizer. The particles were branched into two, each of which passed through a wire-to-plate type charging section where a positive or a negative DC high voltage was applied and was charged positively or negatively. These bipolarly charged particles together passed through an agglomeration section where an $\pm$20kV AC power was applied between two plates. The resident time in the agglomeration section was adjusted as l sec. Particle sampling was made by a cascade impactor (MOUDI). The effect of agglomeration system on the reduction ratio of particles below l ㎛ was 42∼45%. Effect of AC frequency on the particle size distribution was found insignificant.

Limnophila crane flies(Diptera: Limoniidae) of Korea

  • Podenas, Sigitas;Park, Sun-Jae;Byun, Hye-Woo
    • Journal of Species Research
    • /
    • v.11 no.2
    • /
    • pp.117-127
    • /
    • 2022
  • This study is based on crane fly specimens collected during an 80-year period (1937-2017) in the Republic of Korea and Democratic People's Republic of Korea, and are in collections maintained at the United States National Museum, Smithsonian Institution, Washington DC, USA; the Snow Entomological Museum, University of Kansas, Lawrence, KS, USA; and the National Institute of Biological Resources, Incheon, South Korea. These crane flies are developing in wet places which usually prevail at lower altitudes, but such areas are often used for agriculture and human settlements, making natural habitats scarce and fragmented. Probably because of that, Limnophila crane flies are rare on the Korean Peninsula and were unnoticed by previous researchers. The genus Limnophila Macquart, 1834 with three species being new record for the Korean Peninsula: L. (Limnophila) japonica Alexander, 1913, L. (L.) pictipennis (Meigen, 1818) and L. (L.) politostriata Alexander, 1934a. General information are presented for each species, such as on genus and subgenus, redescriptions of species based on Korean specimens, illustrations of both sexes, elevation range, period of activity, habitat information, general distribution, and a distribution map for the Korean Peninsula.

New record of Pilaria crane flies(Diptera: Limoniidae) from Korea

  • Podenas, Sigitas;Park, Sun-Jae;Byun, Hye-Woo
    • Journal of Species Research
    • /
    • v.11 no.1
    • /
    • pp.38-46
    • /
    • 2022
  • This study is based on crane fly specimens collected during more than 80 years, starting from 1938 through 2019, in the Republic of Korea and Democratic People's Republic of Korea and are in collections maintained at the United States National Museum, Smithsonian Institution, Washington DC, USA; the Snow Entomological Museum, University of Kansas, Lawrence, KS, USA; and the National Institute of Biological Resources, Incheon, South Korea. Pilaria crane flies are aquatic and semiaquatic, developing in fast running and stagnant water bodies and in wet muddy places at the margins of water pools. Such habitats usually prevail at lower altitudes, but these areas most often are used for agriculture and human settlement, making natural habitats scarce and fragmented. Pilaria crane flies are rare, thus it is not surprising that genus was left unnoticed by previous researchers. The genus Pilaria Sintenis, 1889 with two species P. melanota Alexander, 1922 and P. simulans Savchenko, 1983, is a new record for the Korean Peninsula. We present general information on the genus, redescriptions of species based on Korean specimens, illustrations of both sexes, elevation range, period of activity, habitat information, general distribution, and a distribution map for the Korean Peninsula for each species.

Optimum Shape Design of Magnetizing Yoke of 2 Pole PM Motor for Cogging Torque Reduction

  • Koh Chang-Seop;Ryu Jae-Seop;Hong Sun-Ki
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.2
    • /
    • pp.168-172
    • /
    • 2005
  • A novel cogging torque reduction algorithm is presented for 2-pole permanent magnet DC motor. While the shape of the permanent magnet is changed in the conventional method, the pole shape of the magnetizing yoke is optimized in the presented algorithm. In order to parameterize the shape of the yoke, and the distribution of the residual magnetization of the permanent magnet, the Bezier spline is used. The shape of the magnetizing yoke is optimized using the design sensitivity analysis incorporated with the finite element method and Bezier spline.

ASSESSMENT OF PROPERTY INTERPOLATION METHODS IN LEVEL SET METHOD (레벨셋 기법의 물성 보간 방법에 대한 고찰)

  • Park, J.K.;Oh, J.M.;Kang, K.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.283-289
    • /
    • 2009
  • In level set method, material properties are made to change smoothly across an interface of two materials with different properties by introducing an interpolation or smoothing scheme. So far, the weighted arithmetic mean (WAM) method has been exclusively adopted in level set method, without complete assessment for its validity. We showed here that the weighted harmonic mean (WHM) method for rate constants of various rate processes, including viscosity, thermal conductivity, electrical conductivity, and permittivity, gives much more accurate results than the WAM method. The selection of interpolation scheme is particularly important in multi-phase electrohydrodynamic problems in which driving force for fluid flow is electrical force exerted on the phase interface. Our analysis also showed that WHM method for both electrical conductivity and permittivity gives not only more accurate, but also more physically realistic distribution of electrical force at the interface. Our arguments are confirmed by numerical simulations of drop deformation under DC electric field.

  • PDF