Experimental Study on Electrical Agglomeration of Liquid Particles in an Alternating Electric Field

AC 전기장내 하전 액체 입자의 응집에 관한 실험적 연구

  • Ji, Jun-Ho (Dept.of Mechanical Engineering, Graduate School of Yonsei University) ;
  • Hwang, Jung-Ho (Dept.of Mechanical Engineering, Yonsei University) ;
  • Bae, Gwi-Nam (Earth Environment Research Center, Korea Institute of Science and Technology) ;
  • Kim, Yong-Gin (-Department of Thermal, Fluid & Environment Engineering, KIMM)
  • 지준호 (연세대학교 대학원 기계공학과) ;
  • 황정호 (연세대학교 기계공학과) ;
  • 배귀남 (한국과학기술연구원 지구환경연구센터) ;
  • 김용진 (한국기계연구원 열유체환경연구부)
  • Published : 2001.03.01

Abstract

Experiments were carried out on agglomeration of bipolarly charged particles in an alternating current electric field. Laboratory-scale setup was built and experiments were conducted at atmospheric condition. DOS(Di-octyl Sebacate) particles with 100% purity were generated by an atomizer. The particles were branched into two, each of which passed through a wire-to-plate type charging section where a positive or a negative DC high voltage was applied and was charged positively or negatively. These bipolarly charged particles together passed through an agglomeration section where an $\pm$20kV AC power was applied between two plates. The resident time in the agglomeration section was adjusted as l sec. Particle sampling was made by a cascade impactor (MOUDI). The effect of agglomeration system on the reduction ratio of particles below l ㎛ was 42∼45%. Effect of AC frequency on the particle size distribution was found insignificant.

Keywords

References

  1. Mohr, M., Ylatalo, S., Klippel, N., Kauppinen, E. I., Riccius, O. and Burtscher, H., 1996, 'Submicron Fly Ash Penetration Through Electrostatic Precipitators at Two Coal Power Plants,' Aerosol Sci. Technol., Vol. 24, pp. 191-204 https://doi.org/10.1080/02786829608965363
  2. Kobashi, M., 1978, Particle Agglomeration Induced by Alternating Electric Fields, Ph.D. Thesis, Stanford University
  3. Mitchner, M. and Self, S., 1983, Basic Studies to Reduce Electrostatic Precipitator Size and Cost, EPRI Report CS-3226
  4. Hautanen, J., Kilpelainen, M., Kauppinen, E. I., Jokiniemi, J. and Lehtinen, K., 1995, 'Electrical Agglomeration of Aerosol Particles in an Alternating Electric Field,' Aerosol. Sci. Technol., Vol. 22, pp 181-189 https://doi.org/10.1080/02786829408959739
  5. Kildeso, J., Bhatia, V. K., Lind, L., Johnson, E. and Johansen, A., 1995, 'An Experimental Investigation for Agglomeration of Aerosols in Alternating Electric Fields,' Aerosol Sci. Technol., Vol. 2, pp. 422-430
  6. Laitinen, A., Hautanen, J. Keskinen, J., Kauppinen, E. Jokiniemi, J. and Lehtinen, K., 1996, 'Bipolar Charged Aerosol Agglomeration with Alternating Electric Field in Laminar Gas Flow,' J. Electrostatics, Vol. 38, pp. 303-315 https://doi.org/10.1016/S0304-3886(96)00038-1
  7. Lehtinen, K., Jokiniemi, J., Kauppinen, E. I. and Hautanen, J., 1995, 'Kinematic Coagulation of Charged Droplets in an Alternating Electric Field,' Aerosol. Sci. Technol., Vol 23, pp 422-430 https://doi.org/10.1080/02786829508965325
  8. Gutsch, A. and Loffler, F., 1994, 'Electrically Enhanced Agglomeration of Nanosized Aerosols,' J. Electrostatics, Vol. 25, pp. 307-308
  9. Watanabe, T., Tochikubo, F., Koizumi, Y., Tsuchida, T., Hautanen, J. and Kauppinen, E., 1995, 'Submicron Particle Agglomeration by an Electrostatic Agglomerator,' J. Aerosol Sci., Vol. 25, pp. s367-383 https://doi.org/10.1016/0304-3886(95)93833-5
  10. 박종인, 지준호, 황정호, 1997, 'LPG 확산화염내 매연입자의 전기적 특성 및 전기장에 의한 입자 크기 변화,' 대한기계학회논문집 B권, 제21권, 제10호, pp. 1326-1338
  11. 김연승, 황정호, 1999, 'AC 주파수의 변화가 입자의 전기 응집에 미치는 연구,' 대한기계학회논문집 B권, 제23권, 제12호, pp. 1527-1534
  12. 지준호, 황정호, 2001, '모멘트법을 이용한 AC 전기장내의 단극성 입자의 전기응집 해석,' 대한기계학회논문집 B권, 제25권, 제1호, pp. 9-17
  13. Forsyth, B., Liu, B. Y. H. and Romay, F. J., 1995, 'Particle Charge Distribution Measurement for Commonly Generated Laboratory Aerosols,' Aerosol Sci. Technol., Vol. 28, pp. 489-501 https://doi.org/10.1080/02786829808965540
  14. 지준호, 황정호, 이규원, 1999, '모멘트법을 이용한 하전 입자들간의 응집 해석,' 대한기계학회논문집 B권, 제23권, 제4호, pp. 431-442
  15. 배귀남, 지준호, 문길주, 1999, '다단 임팩터(MOUDI)의 조대 입자 채취 특성,' 한국대기환경학회지, 제15권, 제6호, pp. 799-804