• Title/Summary/Keyword: DC/DC Voltage Regulator

Search Result 102, Processing Time 0.024 seconds

A Active Replica LDO Regulator with DC Matching Circuit (DC정합회로를 갖는 능동 Replica LDO 레귤레이터)

  • Ryu, In-Ho;Bang, Jun-Ho;Yu, Jae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2729-2734
    • /
    • 2011
  • In this paper, an active replica Low-dropout(LDO) regulator with DC voltage matching circuit is presented. In order to match the voltage between replica and output of regulator, DC voltage matching circuit is designed. The active replica low dropout regulator has higher Power Supply Rejection(PSR) than that of conventional regulator. The designed DC voltage matching circuit can reduce the drawback that may be occurred in replica regulator. And using fully active element in regulator can reduce the chip area and heat noise with resistor. As results of HSPICE simulation with 0.35um CMOS parameter, the designed active replica LDO regulator achieves Power Supply Rejection, -28@10Hz better than -17@10Hz of conventional replica regulator without DC matching circuit. And the output voltage is 3V.

Design of a DC-DC Converter for CMOS Image Sensors in Bio-sensor Chips (바이오센서용 CMOS 이미지 센서를 위한 DC-DC Converter 설계)

  • Park, Heon;Ha, Pan-Bong;Kim, Young-Hee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.6
    • /
    • pp.553-558
    • /
    • 2016
  • A DC-DC converter for CMOS image sensors in bio-sensor chips is proposed. The DC-DC converter generates a PCP voltage, that is an on voltage of a pixel, and an NCP voltage, that is an off voltage of a pixel. The PCP voltage with a ripple voltage of within 1.33V is obtained from a positive charge pump of VPP (=5V) with a ripple voltage of 45.35 by using a regulator. Also, the NCP voltage with a ripple voltage of 0.05mV is obtained from a negative charge pump of VNN (=-2V) with a ripple voltage of 62.8 by using a regulator.

Novel Two Stage AC-to-DC Converter with Single Switched Zero Voltage Transition Boost Pre-Regulator using DC-Linked Energy Feedback (새로운 영전압 스위칭 이단방식의 고역률 컨버터)

  • Roh, Chung-Wook;Moon, Gun-Woo;Jung, Young-Seok;Youn, Myung-Joong
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.385-387
    • /
    • 1996
  • A novel two stage soft-switching ac-to-dc convener with power factor correction is proposed. The proposed convener provides zero-voltage-switching (ZVS) condition to main switch of boost pre-regulator without auxiliary switch. Comparing to the conventional two stage approach(ZVS-PWM boost rectifier followed by off-line ZVS dc-dc step down converter), the proposed approach is simple and reducing EMI noise problem. A new simple DC-linked energy feedback circuit provides zero-voltage-switching condition to boost pre-regulator without imposing additional voltage and current stresses and loss of PWM capability. Operational principle, analysis, control of the proposed converter together with the simulation results of 1KW prototype are presented.

  • PDF

An analysis and control of double chopper DC-DC converter (이중 쵸퍼 DC-DC 컨버터의 해석과 제어)

  • Han, Sang-Wan;Sin, Dong-Hee;Hong, Seok-Gyo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.6
    • /
    • pp.576-581
    • /
    • 1997
  • DC-DC converter with chopper is seen to have problems, such as, loop instability and degradation of transient response, due to the interaction between input filter and switching regulator. In this paper, the switching regulator consisting of input filter and double chopper is analyzed, and the state space model at continuous current mode and the transfer function between duty ratio of switching pulse and output voltage are derived. The controller in this paper is designed as feedforward(P) and feedback(PI) control scheme to minimize the variation of output voltage, and computer simulation results are presented to show the performance of the proposed controller.

  • PDF

Design of DC-DC Converter for Low-Voltage EEPROM IPs (저전압 EEPROM IP용 DC-DC Converter 설계)

  • Jang, Ji-Hye;Choi, In-Hwa;Park, Young-Bae;Jin, Liyan;Ha, Pan-Bong;Kim, Young-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.852-855
    • /
    • 2012
  • A DC-DC converter for EEPROM IPs which perfom erasing by the FN (Fowler-Nordheim) tunneling and programming by the band-to-band tunneling is designed in this paper. For the DC-DC converter for EEPROM IPs using a low voltage of $1.5V{\pm}10%$ as the logic voltage, a scheme of using VRD (Read Voltage) instead of VDD is proposed to reduce the pumping stages and pumping capacitances of its charge pump circuit. VRD ($=3.1V{\pm}0.1V$) is a regulated voltage by a voltage regulator using an external voltage of 5V. The designed DC-DC converter outputs VPP (=8V) and VNN (=-8V) in the write mode.

  • PDF

A Study on the Efficiency Improvement Method of Photovoltaic System Using DC-DC Voltage Regulator (DC-DC 전압 레귤레이터를 이용한 태양광전원의 효율향상 방안에 관한 연구)

  • Tae, Donghyun;Park, Jaebum;Kim, Miyoung;Choi, Sungsik;Kim, Chanhyeok;Rho, Daeseok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.704-712
    • /
    • 2016
  • Recently, the installation of photovoltaic (PV) systems has been increasing due to the worldwide interest in eco-friendly and infinitely abundant solar energy. However, the output power of PV systems is highly influenced by the surrounding environment. For instance, a string of PV systems composed of modules in series may become inoperable under cloudy conditions or when in the shade of a building. In other words, under these conditions, the existing control method of PV systems does not allow the string to be operated in the normal way, because its output voltage is lower than the operating range of the grid connected inverter. In order to overcome this problem, we propose a new control method using a DC-DC voltage regulator which can compensate for the voltage of each string in the PV system. Also, based on the PSIM S/W, we model the DC-DC voltage regulator with constant voltage control & MPPT (Maximum Power Point Tracking) control functions and 3-Phase grid connected inverter with PLL (Phase-Locked Loop) control function. From the simulation results, it is confirmed that the present control method can improve the operating efficiency of PV systems by compensating for the fluctuation of the voltage of the strings caused by the surrounding conditions.

Failure Analysis of Solar Array Regulator Controller for Charging Satellite Battery (위성 배터리 충전을 위한 태양전력조절기의 제어기 고장 분석)

  • Yang, JeongHwan;Park, JeongEon;Yun, SeokTeak
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.4
    • /
    • pp.67-71
    • /
    • 2017
  • A solar array is main electrical energy source for Low-Earth-Orbit(LEO) satellite. The solar array cannot generate electrical energy during eclipse period, a battery supply electrical energy to the satellite. The electrical power of the solar array is changed in accordance with operating voltage and the solar array has the maximum power point. The solar array regulator makes the solar array supply electrical energy to the satellite and charge the battery. The solar array is connected to the solar array regulator input and the battery is connected to the solar array regulator output. The solar array regulator consists 2 of 3 hot redundant. One solar array regulator contains 3 DC-DC converters, and the solar array regulator operates stably even if the failure occur in one DC-DC converter. In this paper, the solar array regulator, the battery and the solar array operation is analyzed when the failure occur in one DC-DC converter.

Implementation and Characteristic Analysis of DC/DC Voltage Regulator for Operation Efficiency Improvement in PV system (태양광발전의 운용효율 향상을 위한 DC/DC 전압 레귤레이터의 구현 및 특성분석)

  • Kim, Chanhyeok;Choi, Sungsik;Kang, Minkwan;Jung, Youngmun;Rho, Daeseok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.201-208
    • /
    • 2017
  • Recently, the installation of photovoltaic(PV) systems has been increasing due to the worldwide interest in eco-friendly and abundant solar energy. On the other hand, a PV system has approximately 25% power loss while the energy generated from solar cells is transformed to the power coupling point through a power conversion system (DC/AC). If the output voltage of a string in the PV system is lower than the operating range of the inverter when a part of module in the string has a shadow due to weather conditions, the string is not synchronized and the whole efficiency of output power in a PV system may be reduced significantly. Therefore, to overcome this problem, this paper proposes a novel control method to compensate for the lower voltage by introducing a DC/DC voltage regulator for each string in a PV system, which adopts a concept for MPPT (Maximum Power Point Tracking) control function using the P&O algorithm and adopts constant voltage control method used in an existing inverter. This paper also implements a 2kW DC/DC voltage regulator based on the proposed algorithm and performs a variety of scenario-based experiments. From the simulation result, it was confirmed that the operation efficiency in the proposed method is improved compared to the existing method.

Phase Shift Control for Series Active Voltage Quality Regulators

  • Xiao, Guochun;Teng, Guofei;Chen, Beihai;Zhang, Jixu
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.664-676
    • /
    • 2012
  • A phase shift algorithm based on the closed-loop control of dc-link voltage implemented on a series active voltage quality regulator (AVQR) is proposed in this paper. To avoid pumping-up the dc-link voltage, a general phase shift compensation strategy is applied. The relationships among the operation variables are discussed in detail, which is very important for guiding the design of both the main circuit and the control system. Then on the basis of an investigation of the dc-link voltage pumping-up from viewpoint of the active power flow, a novel phase shift control method based on the closed-loop of the dc-link voltage is proposed. This method can adjust the phase of the output voltage gradually and automatically according to the dc-link voltage variation without introducing a phase jump. The effectiveness of the proposed strategy is verified through simulations of a single-phase 5kVA prototype and laboratory experiments on both a single-phase 5kVA and a three-phase 15kVA prototype.

The Design of DC-DC Converter with Green-Power Switch and DT-CMOS Error Amplifier (Green-Power 스위치와 DT-CMOS Error Amplifier를 이용한 DC-DC Converter 설계)

  • Koo, Yong-Seo;Yang, Yil-Suk;Kwak, Jae-Chang
    • Journal of IKEEE
    • /
    • v.14 no.2
    • /
    • pp.90-97
    • /
    • 2010
  • The high efficiency power management IC(PMIC) with DTMOS(Dynamic Threshold voltage MOSFET) switching device and DTMOS Error Amplifier is presented in this paper. PMIC is controlled with PWM control method in order to have high power efficiency at high current level. Dynamic Threshold voltage CMOS(DT-CMOS) with low on-resistance is designed to decrease conduction loss. The control parts in Buck converter, that is, PWM control circuits consist of a saw-tooth generator, a band-gap reference circuit, an DT-CMOS error amplifier and a comparator circuit as a block. the proposed DT-CMOS Error Amplifier has 72dB DC gain and 83.5deg phase margin. also Error Amplifier that use DTMOS more than CMOS showed power consumption decrease of about 30%. DC-DC converter, based on Voltage-mode PWM control circuits and low on-resistance switching device is achieved the high efficiency near 96% at 100mA output current. And DC-DC converter is designed with Low Drop Out regulator(LDO regulator) in stand-by mode which fewer than 1mA for high efficiency.