• Title/Summary/Keyword: D1/D2

Search Result 38,924, Processing Time 0.069 seconds

Sector-Based Device Discovery Scheme for D2D Communication in LTE-Advanced Networks (LTE-Advanced 네트워크에서 D2D 통신을 위한 섹터 기반 디바이스 디스커버리 기술)

  • Kim, Hyang-mi;Lee, Han-na;Kim, Sangkyung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.8
    • /
    • pp.1521-1531
    • /
    • 2015
  • According to the service attributes, D2D communications establish 1-1, or 1-n channels and require the differentiated device discovery technology. This paper proposes a sector-based device discovery mechanism for 1-n D2D communication scenario in LTE-Advanced networks that a disaster happened. Our proposal is a mechanism that can extend the coverage in a disaster situation which a number of devices(survivors) need to be discovered in a short time. In the single cell environment, a larger discovery coverage can be obtained, and in the multi-cell, it is possible to mitigate the interference with adjacent links due to sector-based coverage control. Through a set of simulations, we have confirmed that our proposal has better performance in the number of devices discovered and the interference than the legacy broadcast device discover mechanism.

Effects of Noise and Vibration on Oxygen Consumption and Ammonia Excretion in Cultured Catfish (Silurus asotus) (양식장에서 사육하는 메기 (Silurus asotus)의 산소소비 및 암모니아 배설에 미치는 소음진동 영향)

  • Hur, Jun Wook;Lee, Jeong Yeol;Joo, Jin Chul
    • Ecology and Resilient Infrastructure
    • /
    • v.5 no.2
    • /
    • pp.105-109
    • /
    • 2018
  • The main objective of this investigation was to examine oxygen consumption and ammonia excretion within cultured catfish, Silurus asotus ($22.9{\pm}0.9cm$, $100.7{\pm}11.7g$ n = 30) by noise and vibration stress in aquaculture farm. The vibration of 48, 58 and 68 dB (V) and noise of $77.6{\pm}1.8dB$ (A) from an electric vibrator was turned on for 15 minutes during each hour each day(0800-1800) for 11 days experimental period. The oxygen consumption (OC) of S. asotus the beginning of the experiment (0 day) in 58 dB group after 1, 5, 9 and 11 days was decreased 21.8, 30.2, 36.0 and 53.2%, respectively. In 68 group after 1, 7 and 11 days was decreased 22.7, 35.1 and 57.7%, respectively. The OC decreased exponentially and the relationship between them was expressed as OC = 0.374D + 90.762 ($r^2=0.048$) at 48 dB, OC = -3.581D + 89.520 ($r^2=0.831$) at 58 dB and OC = -4.109D + 90.907 ($r^2=0.884$) at 68 dB. Ammonia excretion (AE) of the beginning of the experiment in 48, 58 and 68 groups after 1 day was increased by 34.8, 51.8 and 63.2%, respectively, but it was decreased significantly from 3 to 11 days. The AE increased exponentially and the relationship between them was expressed as AE = -1.646D + 115.915 ($r^2=0.265$) at 48 dB, AE = -8.230D + 122.132 ($r^2=0.750$) at 58 dB and AE = -7.086D + 123.690 ($r^2=0.614$) at 68 dB.

A Study for the Norms of Audiometric Tests in Koreans (정상한국인의 청력검사치에 관한 연구)

  • 오혜경;서장수;이근해;김희남;김영명;권영화;서옥기
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.38.1-38
    • /
    • 1981
  • Currently in the otologic field, there are various methods of special audiometric examinations, such as, tone decay, SISI, and impedance audiometry and only a few studies has been done in these fields sporadically in Korea. The purpose of this paper is to establish norms of various special audiometric tests, so we have performed the special audiometric tests on 100 male medical students in good physical condition and the follow results were obtained. 1. All cases showed over 90% of PB scores. The mean and its 2 S.D. were 98$\pm$4.9% in the right ear and 97$\pm$5.6% in the left ear. 2. The mean and its 2 S.D. of MCL(most comfortable level) were 45$\pm$15.4 dB in the right ear and 46$\pm$17.9 dB in the left ear, and its range was 12$\pm$12.2 dB in the right ear and 13$\pm$12.6 dB in the left ear. 3. The mean and its 2 S.D. of UCL (uncomfortable level) were 102$\pm$7.9 dB in the right ear and 102$\pm$7.9 dB in the left ear and about an half in cases showed over 106 dB of UCL. 4. In 95% of cases, SISIs(short increment sensitivity index) at 1, 000 Hz and 4000 Hz was below 45% in the right ear in both frequencies and below 55% and 75% in the left ear, respectively. 5. In 95% of cases, tone decays at 2, 000 Hz and 4, 000 Hz was below 10 dB in both ears. 6. The difference between SRT and PTA (speech reception threshold minus pure tone average) was 4$\pm$9.2 dB in the right ear and 4$\pm$10.0 dB in the left ear. 7. The dynamic range(uncomfortable level minus speech reception threshold) was 98$\pm$13.5 dB in the right ear and 99$\pm$13.5 dB in the left ear. We had trouble in estimating the dynamic range in about an half in cases, in which we couldn't estimate the UCL with our conventional audiometry. 8. The results of impedance audiometric tests were as follow: A. In the tympanogram, all cases were of A type with one exception of B type in the left ear. The mean and its 2 S.D. of its peak level were 22.8$\pm$32.94mm $H_2O$ in the right ear and 23.9$\pm$29. 81mm $H_2O$ in the left ear. B. The mean and its 2 S.D. of the compliance were 0.6$\pm$0.54cc in the right ear and 0.6$\pm$0.53cc in the left ear. C. The results of stapedial reflex: a. The mean and its 2 S.D. of the controlateral stapedial reflex at 500Hz, 1, 000Hz, 2, 000Hz, 4, 000Hz were 99$\pm$17.7 dB, 87$\pm$14.4 dB, 79$\pm$13.7 dB, 77$\pm$20.0 dB in the right ear and 99$\pm$15.9 dB, 88$\pm$13.9 dB, 79$\pm$13.7 dB, 77$\pm$21.3 dB in the left ear. Depending on the tested frequencies, the stapedial reflex wasn't generated in 6 cases in the right ear and 11 cases in the left ear. b. The mean and its 2 S.D. of the ipsilateral stapedial reflex at 1, 000Hz, and 2, 000Hz were 89$\pm$16.3 dB, 82$\pm$15.9 dB in the right ear and 89$\pm$18.0 dB, 83$\pm$18.9 dB in the left ear. Depending on the tested frequencies, the stapedial reflex wans't generated in 1 case in the right ear and 2 cases in the left ear. 9. Eustachian tube function using with impedance audiometry was malfunctioned in21 cases depending on the tested pressure and the range of peak level of tympanogram was 14$\pm$26.9mm $H_2O$(tested pressure:+250mm $H_2O$), 8$\pm$21.9mm $H_2O$ (tested pressure:-250mm $H_2O$) in the right ear and 11 cases depending on the tested pressure and the range of the peak level of tympanogram was 12$\pm$22.5mm $H_2O$ (tested pressure: +250 mm $H_2O$, 9$\pm$17.3mm $H_2O$(tested pressure: -250mm $H_2O$) in the left ear.

  • PDF

Physiological Response of Four Corn Cultivars to Soil Salinity (토양염농도에 따른 식용옥수수 품종들의 생장특성)

  • Kim, Sun;Choi, Weon-Young;Jeong, Jae-Hyeok;Lee, Kyung-Bo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.59 no.3
    • /
    • pp.293-298
    • /
    • 2014
  • This study conducted experiments on the reclaimed land of Saemangeum located in Jeongrabuk-do in order to gain basic information about growth characteristics and yield ability according to soil salinity. Having soil excluding salt as a control group, this study adjusted the specimens' soil salinity to level 4 and then planted four varieties including Ilmichal Corn to investigate the growth or grain yield according to salinity. About the corn establishment rate according to soil salinity, over 97% up to $3.2dS\;m^{-1}$ was established, and then, it was reduced gradually according to the increase of concentration. According to the salt concentration of soil more required growth duration from seeding to heading comparing to non-treatment salt was delayed, at $1.6dS\;m^{-1}$, two days were delayed, at $3.2dS\;m^{-1}$, four to six days were delayed differently by varieties, and at $4.8dS\;m^{-1}$, six to 10 days were delayed. About the plant fresh weight according to soil salinity, Chalok 4 and Eolrukchal indicated 93%~97% or so compared with the salt-free one at $1.6dS\;m^{-1}$, and Chalok No. 4 showed 79% at the salinity of $3.2dS\;m^{-1}$, too, and it was a relatively higher growth percentage than those of the other varieties. In terms of dried seed weight according to soil salinity, compared with the corns cultivated in the control group, averagely 12.1% was lowered at the time of cultivation at $1.6dS\;m^{-1}$, and $3.2dS\;m^{-1}$ 40% was lowered, and about 70% was lowered at $4.8dS\;m^{-1}$. According to the result of examining the point of time that dried seed start to reduce due to soil salinity with the regression equation, soil salinity which starts the reduction of grain weight is $1.67dS\;m^{-1}{\sim}2.18dS\;m^{-1}$, and it differs by varieties, and EC of 50% that the yield reduces in half is $2.96dS\;m^{-1}{\sim}4.45dS\;m^{-1}$. And the degree of influence on each of the growth factors according to soil salinity is founded to be in the order of establishment rate

A Study on the Electromigratin Phenomena in Dielectric Passivated Al-1Si Thin Film Interconnections under D.C. and Pulsed D.C.Conditions. (절연보호막 처리된 Al-1 % Si박막배선에서 D.C.와 Pulsed D.C. 조건하에서의 electromigration현상에 관한 연구)

  • 배성태;김진영
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.3
    • /
    • pp.229-238
    • /
    • 1996
  • The electromigration phenomena and the characterizations of the conductor lifetime (Time-To-Failure, TTF) in Al-1%Si thin film interconnections under D.C. and Pulsed D.C. conditions were investigated . Meander type test patterns were fabricated with the dimensions of 21080$mu \textrm{m}$ length, 3$\mu\textrm{m}$ width, 0.7$\mu\textrm{m}$ thickness and the 0.1$\mu\textrm{m}$/0.8$\mu\textrm{m}$($SiO_2$/PSG)dielectric overlayer. The current densities of $2 \times10^6 A/\textrm{cm}^2$ and $1 \times10^7 A/\textrm{cm}^2$ were stressed in Al-1%Si thin film interconnection s under a D.C. condition. The peak current densities of $2 \times10^6 A/\textrm{cm}^2$ and $1 \times10^7 A/\textrm{cm}^2$ were also applied under a Pulsed D.C. condition at frequencies of 200KHz, 800KHz, 1MHz, and 4MHz with the duty factor of 0.5. THe time-to-failure under a Pulsed D.C.($TTF_{pulsed D.C}$) was appeared to be larger than that under a D.C. condition. It was found that the TTF under both a D.C. and a Pulsed D.C. condition. It was found that the TTF under both a D.C. and a Pulsed D.C. condition largely depends upon the appiled current densities respectively . This can be explained by a relaxation mechanism view due to a duty cycle under a Pulsed D.C. related to the wave on off. The relaxation phenomena during the pulsed off period result in the decayof excess vacancies generated in the Al-1%Si thin film interconnections because of the electrical and mechanical stress gradient . Hillocks and voids formed by an electromigration were observed by using a SEM (Scanning Electron Microscopy).

  • PDF

AN EFFECT OF ND : YAG LASER ON THE BONDING STRENGTH OF COMPOSITE RESIN TO DENTIN AND PORCELAIN (Nd : YAG 레이저가 상아질 및 도재와 복합레진간의 결합강도에 미치는 영향)

  • Woo, Gum-Jin;Yang, Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.2
    • /
    • pp.385-399
    • /
    • 1997
  • The purpose of this experiment was to determine the effects of etching with a Nd : YAG Laser on dentin, or porcelain surface on the bond strength with composite resin. The dentin specimens were devided into the following 4 groups. D1 : No treatment D2 : Etched with 10% phosphoric acid D3 : Laser etchded with 1W, 20PPs D4 : Laser etched with 2W, 20PPS The procelain specimens were devided into the following 4 groups. P1 : diamond roughened P2 : etched with HF acid P3 : Laser etched with 2W, 20PPS P4 : Laser etched with 3W, 20PPS All specimens were veneered with resin. One half of the specimens were stored in $37^{\circ}C$ water for one day and the other half were thermocycled 1000 times at temperature of $5^{\circ}C\;to\;55^{\circ}C$ at 20 seconds intervals. After that, the bonding strength of composite resin to the dentin and porcelain was measured. The surface treated state and fractured state were observed with SEM. The following results were obtained. 1. In the dentin specimens, the bond strength of group D2 was highter than that of groups D1 and D3 in the case of the specimens stored in $37^{\circ}C$ water for one day, there was a statistically significant difference between group D2 and D1, D3 (P<0.05). The bonding strength of the specimens that were thermocycled decreased in the following order : group D2,D4,D3 and then D1. 2. In the porcelain specimens, the bonding strength of groups P1,P2 were higher than that of group P3 in the case of the specimens stored in $37^{\circ}C$ water for one day (P<0.05). The bonding strength of the specimens of being thermocycled decreased in the following order : group P2,P1,P4 and then P3. 3. The groups of high bond strength had a rougher surface and a high level of microporosity with SEM findings.

  • PDF

SYSTEMS OF DERIVATIONS ON BANACH ALGEBRAS

  • Lee, Eun-Hwi
    • Communications of the Korean Mathematical Society
    • /
    • v.12 no.2
    • /
    • pp.251-256
    • /
    • 1997
  • We show that a strong system of derivations ${D_0, D_1,\cdots,D_m}$ on a commutative Banach algebra A is contained in the radical of A if it satisfies one of the following conditions for separating spaces; (1) $\partial(D_i) \subseteq rad(A) and \partial(D_i) \subseteq K D_i(rad(A))$ for all i, where $K D_i(rad(A)) = {x \in rad(A))$ : for each $m \geq 1, D^m_i(x) \in rad(A)}$. (2) $(D^m_i) \subseteq rad(A)$ for all i and m. (3) $\bar{x\partial(D_i)} = \partial(D_i)$ for all i and all nonzero x in rad(A).

  • PDF

A Study on the Noise Correction Factor in Apartment Complex (공동주택에서의 소음보정계수에 관한 연구)

  • Lee, Nae Hyun;Sunwoo, Young;Park, Young Min;Park, Sun Hwan;Cho, Il-Hyoung
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.5
    • /
    • pp.247-254
    • /
    • 2005
  • Road traffic noise has increasing broader effects on urban areas as well as rural areas because of rapidly increasing traffic volume and newly-constructed roads. 10 sites in building development areas were selected and the noise level were measured by the apartment floors and by the various block plans of apartment complex. Analysis result, about correction factor, in the case of right angle arrangement, apply - 2.5dB(A). In the case of apartment house correlation of each floor apply 1st floors 0dB(A), 2st floors 1.2dB(A), 3st floors 2.1dB(A), 4st floors 2.6dB(A), 5st floors 2.7dB(A), 6st floors 2.7dB(A), 7st floors 2.4dB(A), 8st floors 2.0dB(A), 9st floors 1.6dB(A), 10st floors 1.1dB(A), 13st floors 0.2dB(A), 15st floors 0.5dB(A). The level of road traffic noise in the arrangement construction of right angle was about 3.0dB(A) at N-4 point and 2.1dB(A) at N-6 point lower than that of a plan figure, respectively. The results suggested that application of correction coefficient obtained by the apartment floor and by the arrangement construction can be improved in road traffic noise. The results suggested that application of correction coefficient obtained by the apartment floor and by the arrangement construction can be improved in road traffic noise.

Assessing the capability of HEC-RAS coupled 1D-2D model through comparison with 2-dimensional flood models

  • Dasallas, Lea;An, Hyunuk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.158-158
    • /
    • 2019
  • Recent studies show the possibility of more frequent extreme events as a result of the changing climate. These weather extremes, such as excessive rainfall, result to debris flow, river overflow and urban flooding, which post a substantial threat to the community. Therefore, an effective flood model is a crucial tool in flood disaster mitigation. In recent years, a number of flood models has been established; however, the major challenge in developing effective and accurate inundation models is the inconvenience of running multiple models for separate conditions. Among the solutions in recent researches is the development of the combined 1D-2D flood modeling. The coupled 1D-2D river flood modeling allows channel flows to be represented in 1D and the overbank flow to be modeled over two-dimension. To test the efficiency of this approach, this research aims to assess the capability of HEC-RAS model's implementation of the combined 1D-2D hydraulic simulation of river overflow inundation, and compare with the results of GERIS and FLUMENS 2D flood model. Results show similar output to the flood models that had used different methods. This proves the applicability of the HEC-RAS 1D-2D coupling method as a powerful tool in simulating accurate inundation for flood events.

  • PDF

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.