• Title/Summary/Keyword: D(X)

Search Result 6,275, Processing Time 0.033 seconds

Exploring Thermoelectric Transport Properties and Band Parameters of n-Type Bi2-xSbxTe3 Compounds Using the Single Parabolic Band Model

  • Linh Ba Vu;Soo-ho Jung;Jinhee Bae;Jong Min Park;Kyung Tae Kim;Injoon Son;Seungki Jo
    • Journal of Powder Materials
    • /
    • v.31 no.2
    • /
    • pp.119-125
    • /
    • 2024
  • The n-type Bi2-xSbxTe3 compounds have been of great interest due to its potential to achieve a high thermoelectric performance, comparable to that of p-type Bi2-xSbxTe3. However, a comprehensive understanding on the thermoelectric properties remains lacking. Here, we investigate the thermoelectric transport properties and band characteristics of n-type Bi2-xSbxTe3 (x = 0.1 - 1.1) based on experimental and theoretical considerations. We find that the higher power factor at lower Sb content results from the optimized balance between the density of state effective mass and nondegenerate mobility. Additionally, a higher carrier concentration at lower x suppresses bipolar conduction, thereby reducing thermal conductivity at elevated temperatures. Consequently, the highest zT of ~ 0.5 is observed at 450 K for x = 0.1 and, according to the single parabolic band model, it could be further improved by ~70 % through carrier concentration tuning.

Development of A Horizontal Scroll Arcade Mobile Game Using Cocos2d-x (2D 그래픽 프레임워크 Cocos2d-x 기반 횡 스크롤 아케이드 모바일 게임 개발)

  • Choi, Ji-Hyun;Youn, Hee-Yong
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2014.01a
    • /
    • pp.469-472
    • /
    • 2014
  • 본 논문은 멀티 플랫폼을 지원하는 Cocos2d-x를 기반으로 하여 Android와 iOS에서 구동하는 네이티브앱의 개발 모델을 제안하고 실제로 구현한 횡 스크롤 모바일 게임을 기술한다. 모바일 게임 장르 중 아케이드 장르가 대중성과 중독성도 있는 만큼 사용자의 비율이 가장 높은 것을 바탕으로 2d 그래픽 프레임워크 Cocos2d-x 기반 가속도 센서를 이용하여 횡 스크롤 아케이드 모바일 게임을 개발하였다.

  • PDF

The Evaluation of TrueX Reconstruction Method in Low Dose (저선량에서의 TrueX 재구성 방법에 의한 유용성 평가)

  • Oh, Se-Moon;Kim, Kye-Hwan;Kim, Seung-Jeong;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.83-87
    • /
    • 2011
  • Purpose: Recently in diagnostics area PET/CT is using a variety of areas including oncology, as well as in cardiology, neurology, etc. While increasing in the importance of PET/CT, there are various researches in the image quality related to reconstruction method. We compared and tested Iterative 2D Reconstruction Method with True X Reconstruction method by Siemens through phantom experiment, so we can see increasing of clinical usefulness of PET/CT. Materials and Methods: We measured contrast ratio and FWHM due to evaluating images on dose and experiment using Biograph 40 True Point PET/CT (Siemens, Germany). Getting a result of contrast ratio and FWHM, we used NEMA IEC PET body phantom (Data Spectrum Corp.) and capillary tube. We used the current TrueX and the previous Iterative 2D algorithm for all images which have 10 minutes long. Also, a clinical suitability of parameter for Iterative 2D and a recommended parameter by Siemens for True X are applied to the experiment. Results: We tested FWHM using capillary tube. As a result, TrueX was less than Iterative 2D. Also, the differences of FWHM get bigger in low dose. On the other hand, we tested contrasts ratio using NEMA IEC PET body phantom. As a result, TrueX was better aspect than Iterative 2D. However, there was no difference in dose. Conclusion: In this experiment, TrueX get higher results of contrast ratio and spatial resolution than Itertive 2D through experiment. Also, in the reconstruction result through TrueX, TrueX had better aspect of resolution than Iterative 2D in low dose. However, contrast ratio had no specific difference. In other words, TrueX reconstruction method in PET/CT had higher clinical value in use because TrueX can reduce exposure of patient and had a better quality of screen.

  • PDF

MONITORING OF REMINERALIZATION OF DECALCIFIED ENAMEL USING QUANTITATIVE LIGHT-INDUCED FLUORESCENCE-D (Quantitative light-induced fluorescence-D를 이용한 탈회 법랑질의 재석회화 감시)

  • You, Yon-Sook;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.3
    • /
    • pp.257-266
    • /
    • 2012
  • The objective of this in vitro study was to monitor the amount of remineralization of decalcified enamel according to the number of fluoride varnish application using quantitative light-induced fluorescence-D and polarizing microscope. Artificial white lesion induced on the sound 72 teeth, $CavityShield^{TM}$ (Group I), $FluroDose^{TM}$ (Group II) and $Flor-Opal^{(R)}$ Varnish (Group III) were applied 1, 2 or 3 times every two weeks. The following results was obtained: 1. In group I, II and III, ${\Delta}L$ were increased. From regression analysis of ${\Delta}L$ by the number of application, the equation was y = 3.878x + 90.612 in group I, y = 3.133x + 37.168 in group II, and y = 3.509x + 82.322 in group III(p < 0.05). 2. In group I, II and III, ${\Delta}D$ were decreased. From regression analysis of ${\Delta}D$ by the number of application, the equation was y = -2.336x + 107.235 in group I, y = -2.158x + 101.620 in group II, and y = -1.940x + 94.806 in group III(p < 0.05). 3. The Pearson correlation value between the ${\Delta}L$ and ${\Delta}D$ was -0.673 in group I, -0.574 in group II, and -0.431 in group III(p < 0.05).

Design and Fabrication of the Frequency Multiplier for S-band Transponder (S-대역 트랜스폰더용 주파수 체배기 설계 및 제작)

  • Kim, Byung-Soo;Ko, Bong-Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.10 no.4
    • /
    • pp.348-355
    • /
    • 2006
  • In this paper, frequency multipliers used S-band transponder of the KOMPSAT 3 are designed and fabricated. In the transponder, 108 times multiplier which generate 1st LO signal(2008.8MHz) is comprised of the X9 frequency multiplier, 1st X2 multiplier, 2nd X2 multiplier and the last stage of the X3 frequency multiplier. As results, output power of 8.17 dBm at 2008.8MHz, the harmonic suppression of -56.67dBc, the bandwidth of 14MHz were measured.

  • PDF

3D Coordinates Acquisition by using Multi-view X-ray Images (다시점 X선 영상을 이용한 3차원 좌표 획득)

  • Yi, Sooyeong;Rhi, Jaeyoung;Kim, Soonchul;Lee, Jeonggyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.10
    • /
    • pp.886-890
    • /
    • 2013
  • In this paper, a 3D coordinates acquisition method for a mechanical assembly is developed by using multiview X-ray images. The multi-view X-ray images of an object are obtained by a rotary table. From the rotation transformation, it is possible to obtain the 3D coordinates of corresponding edge points on multi-view X-ray images by triangulation. The edge detection algorithm in this paper is based on the attenuation characteristic of the X-ray. The 3D coordinates of the object points are represented on a graphic display, which is used for the inspection of a mechanical assembly.

THE RANGE INCLUSION RESULTS FOR ALGEBRAIC NIL DERIVATIONS ON COMMUTATIVE AND NONCOMMUTATIVE ALGEBRAS

  • Toumi, Mohamed Ali
    • The Pure and Applied Mathematics
    • /
    • v.20 no.4
    • /
    • pp.243-249
    • /
    • 2013
  • Let A be an algebra and D a derivation of A. Then D is called algebraic nil if for any $x{\in}A$ there is a positive integer n = n(x) such that $D^{n(x)}(P(x))=0$, for all $P{\in}\mathbb{C}[X]$ (by convention $D^{n(x)}({\alpha})=0$, for all ${\alpha}{\in}\mathbb{C}$). In this paper, we show that any algebraic nil derivation (possibly unbounded) on a commutative complex algebra A maps into N(A), where N(A) denotes the set of all nilpotent elements of A. As an application, we deduce that any nilpotent derivation on a commutative complex algebra A maps into N(A), Finally, we deduce two noncommutative versions of algebraic nil derivations inclusion range.

Optimizing Production of Two Potential Probiotic Lactobacilli Strains Isolated from Piglet Feces as Feed Additives for Weaned Piglets

  • Chiang, Ming-Lun;Chen, Hsi-Chia;Chen, Kun-Nan;Lin, Yu-Chun;Lin, Ya-Ting;Chen, Ming-Ju
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.28 no.8
    • /
    • pp.1163-1170
    • /
    • 2015
  • Two probiotic strains, Lactobacillus johnsonii x-1d-2 and Lactobacillus mucosae x-4w-1, originally isolated from piglet feces, have been demonstrated to possess antimicrobial activities, antibiotic resistances and interleukin-6 induction ability in RAW 267.4 macrophages in our previous study. These characteristics make L. johnsonii x-1d-2 and L. mucosae x-4w-1 good candidates for application in feed probiotics. In this study, soybeal meal, molasses and sodium acetate were selected to optimize the growth medium for cultivation of L. johnsonii x-1d-2 and L. mucosae x-4w-1. These two strains were then freeze-dried and mixed into the basal diet to feed the weaned piglets. The effects of L. johnsonii x-1d-2 and L. mucosae x-4w-1 on the growth performance and fecal microflora of weaned piglets were investigated. The results showed that the bacterial numbers of L. johnsonii x-1d-2 and L. mucosae x-4w-1 reached a maximum of 8.90 and 9.30 log CFU/mL, respectively, when growing in optimal medium consisting of 5.5% (wt/vol) soybean meal, 1.0% (wt/vol) molasses and 1.0% (wt/vol) sodium acetate. The medium cost was 96% lower than the commercial de Man, Rogosa and Sharpe medium. In a further feeding study, the weaned piglets fed basal diet supplemented with freeze-dried probiotic cultures exhibited higher (p<0.05) body weight gain, feed intake, and gain/feed ratio than weaned piglets fed basal diet. Probiotic feeding also increased the numbers of lactobacilli and decreased the numbers of E. coli in the feces of weaned piglets. This study demonstrates that L. johnsonii x-1d-2 and L. mucosae x-4w-1 have high potential to be used as feed additives in the pig industry.

Analysis of Optimum Impedance for X-Band GaN HEMT using Load-Pull (로드-풀을 이용한 X-Band GaN HEMT의 최적 임피던스 분석)

  • Kim, Min-Soo;Rhee, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.5
    • /
    • pp.621-627
    • /
    • 2011
  • In this paper, we analysed performance for on-wafer GaN HEMT using load-pull in X-band, and studied optimum impedance point based on analysis result. We suggested method of optimum performance device by analysis of optimum impedance for solid state device on-wafer condition before packaging. The measured device is gate length 0.25um, and gate width is 400um, 800um. device 400um is performed $P_{sat}$=33.16dBm, PAE=67.36%, Gain=15.16dBm, and device 800um is performed $P_{sat}$=35.91dBm, PAE=69.23%, Gain=14.87dBm.

Technical Trend of 3D Graphics for Linux Platforms (리눅스 3D 그래픽 기술 동향)

  • Choi, S.H.;Seol, D.M.;Ahn, S.H.;Lee, K,H.
    • Electronics and Telecommunications Trends
    • /
    • v.21 no.1 s.97
    • /
    • pp.35-43
    • /
    • 2006
  • X 서버는 개발된 지 20년 동안 그리 큰 변경이 이루어지지 않았다. 하지만, 그래픽 하드웨어는 사양은 3D 그래픽 고성능으로 변화되었다. X 서버는 2D 그래픽을 처리하기위한 그래픽 시스템으로 설계되었다. 3D 그래픽 처리를 위해서 OpenGL 라이브러리를X 서버와 연동하는 작업을 해왔지만 구조적으로 3D 그래픽 드로잉을 처리하는 것은 X서버이기 때문에 성능에 한계를 드러내게 되었다. 마이크로소프트사 DirectX 구조처럼직접 그래픽 하드웨어를 제어해서 3D 그래픽 처리를 구현하고 있으며 리눅스 진영은X 서버와 공존하면서 3D 그래픽 처리를 향상시키기 위한 연구를 진행하고 있다. 본 고에서는 리눅스 진영에서 현재 진행중인 향상된 3D 그래픽 처리에 대한 기술 동향을 설명한다.