• Title/Summary/Keyword: Cyclic operation

Search Result 155, Processing Time 0.023 seconds

On the cyclic change in the dynamics of the IBR-2M pulsed reactor

  • Yu.N. Pepelyshev;Sumkhuu Davaasuren
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1665-1670
    • /
    • 2023
  • It is shown that in the IBR-2M reactor by the end of the reactor cycle, changes in dynamics are observed associated with a strong weakening of the fast power feedback (PF), as a result of which the reactor becomes oscillatorily unstable. After each week of zero-power operation the negative changes in reactor dynamics disappear and the stability of the reactor is restored. Thus, the reactor undergoes cyclic changes in the oscillatory instability. The correlation between of a fast PF and a slow PF is experimentally observed, which makes it possible to almost completely eliminate the cyclic component of instability by changing the control mode of rods of the control system.

Numerical analysis of the vertical tube-in-tube ground coil heat exchanger (수직으로 매설된 이중관형 지중 열교환기에 대한 해석적인 연구)

  • 유지오;금성민;신현준
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.339-348
    • /
    • 1999
  • A computer model was developed in order to predict the temperature distribution and the performance of the vertical tube-in-tube ground coil heat exchanger. This model has been validated by experimental results conducted by ORNL. The heat exchanger performance with the variation of the length is calculated and compared. As results, the heat exchanger performance is proportional to the length but the performance per unit length decreases. The minimum performance of 70m - PVC heat exchanger during cyclic operation for a week is obtained 20,054kJ/h for cooling operation and 13,915kJ/h for heating operation. And minimum temperature difference is $4.64^{\circ}C$ for cooling operation and $2.64^{\circ}C$ for heating operation. In each case, it is noted that the temperature difference between the pipe and the far-field occurs within 0.8m from the heat exchanger.

  • PDF

空氣調和機 및 熱펌프에 對한 斷續運轉性能 및 季節의 表示方法

  • 민만기
    • Journal of the KSME
    • /
    • v.22 no.5
    • /
    • pp.341-349
    • /
    • 1982
  • 소비자에게 이러한 마침표에 대한 사전지식을 주는 공기조화. 냉동기계의 성능평가방법에서는 쉴 사이없이 변동하는 외기온도에서의 성능과 부분부하의 단속운전(cyclic operation)에서의 성능을 밝혀주고 이를 기초로 해서 공조기 또는 열펌프의 계절성능을 밝혀주여야 될 것이다. 여기서는 그러한 새로운 계절성능의 평가절차 및 방법 중에서 계절성능을 표시하는 방법과 용어에 대해서 만 해설을 하고자 한다.

  • PDF

Synthesis and Microstructure of Fe-Base Superalloy Powders with Y-Oxide Dispersion by High Energy Ball Milling (고에너지 볼 밀링을 이용한 Y-산화물 분산 Fe-기초내열합금 분말의 합성 및 미세조직 특성)

  • Yim, Da-Mi;Park, Jong Kwan;Oh, Sung-Tag
    • Korean Journal of Materials Research
    • /
    • v.25 no.8
    • /
    • pp.386-390
    • /
    • 2015
  • Fe-base superalloy powders with $Y_2O_3$ dispersion were prepared by high energy ball milling, followed by spark plasma sintering for consolidation. High-purity elemental powders with different Fe powder sizes of 24 and 50 mm were used for the preparation of $Fe-20Cr-4.5Al-0.5Ti-O.5Y_2O_3$ powder mixtures (wt%). The milling process of the powders was carried out in a horizontal rotary ball mill using a stainless steel vial and balls. The milling times of 1 to 5 h by constant operation (350 rpm, ball-to-powder ratio of 30:1 in weight) or cycle operation (1300 rpm for 4 min and 900 rpm for 1 min, 15:1) were applied. Microstructural observation revealed that the crystalline size of Fe decreased with an increase in milling time by cyclic operation and was about 15 nm after 3 h, forming a FeCr alloy phase. The cyclic operation had an advantage over constant milling in that a smaller-agglomerated structure was obtained. The milled powders were sintered at $1100^{\circ}C$ for 30 min in vacuum. With an increase in milling time, the sintered specimen showed a more homogeneous microstructure. In addition, a homogenous distribution of Y-compound particles in the grain boundary was confirmed by EDX analysis.

Dynamic Behaviors of Redox Mediators within the Hydrophobic Layers as an Important Factor for Effective Microbial Fuel Cell Operation

  • Choi, Young-Jin;Kim, Nam-Joon;Kim, Sung-Hyun;Jung, Seun-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.4
    • /
    • pp.437-440
    • /
    • 2003
  • In a mediator-aided microbial fuel cell, the choice of a proper mediator is one of the most important factors for the development of a better fuel cell system as it transfers electrons from bacteria to the electrode. The electrochemical behaviors within the lipid layer of two representative mediators, thionin and safranine O both of which exhibit reversible electron transfer reactions, were compared with the fuel cell efficiency. Thionin was found to be much more effective than safranine O though it has lower negative formal potential. Cyclic voltammetric and fluorescence spectroscopic analyses indicated that both mediators easily penetrated the lipid layer to pick up the electrons produced inside bacteria. While thionin could pass through the lipid layer, the gradual accumulation of safranine O was observed within the layer. This restricted dynamic behavior of safranine O led to the poor fuel cell operation despite its good negative formal potential.

Cooling Performance Measurement of a 3 Room Type Inverter Heat Pump System (3실형 인버터 열펌프 시스템의 냉방성능 측정)

  • 정광진;최영돈;장효환;송재복;박윤철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.431-439
    • /
    • 2001
  • Recently, multi-room type heat pump system has aroused much attention, because it can achieve much reduction of installation cost and space as well as energy saving in companion with the single room type heat pump system. In the present study, performance characteristics of a 3 room type inverter driven heat pump system, which is widely spread in Japanese market, are measured.. In the single room operation, performances of a heat pump system such s the difference of compressor outlet and inlet pressures and the mass flowrate may increase with the increase of cooling capacity so that COP of the system decrease with the increase of cooling capacity. However, in the 2 room operation, mass flowrate and COP of the total system increase markedly as compared with the single room operation.

  • PDF

An Arithmetic System over Finite Fields

  • Park, Chun-Myoung
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.4
    • /
    • pp.435-440
    • /
    • 2011
  • This paper propose the method of constructing the highly efficiency adder and multiplier systems over finite fields. The addition arithmetic operation over finite field is simple comparatively because that addition arithmetic operation is analyzed by each digit modP summation independently. But in case of multiplication arithmetic operation, we generate maximum k=2m-2 degree of ${\alpha}^k$ terms, therefore we decrease k into m-1 degree using irreducible primitive polynomial. We propose two method of control signal generation for the purpose of performing above decrease process. One method is the combinational logic expression and the other method is universal signal generation. The proposed method of constructing the highly adder/multiplier systems is as following. First of all, we obtain algorithms for addition and multiplication arithmetic operation based on the mathematical properties over finite fields, next we construct basic cell of A-cell and M-cell using T-gate and modP cyclic gate. Finally we construct adder module and multiplier module over finite fields after synthesizing ${\alpha}^k$ generation module and control signal CSt generation module with A-cell and M-cell. Next, we constructing the arithmetic operation unit over finite fields. Then, we propose the future research and prospects.

Combustion Characteristics of a Small Diesel Engine Converted to Spark Ignition Operation and Fuelled with Natural Gas (디젤 기관을 개조한 소형 전기점화식 천연가스기관의 연소 특성 연구)

  • Park, S.;.Thomas, D. G.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.6
    • /
    • pp.65-77
    • /
    • 1996
  • A small-sized industrial diesel engine was converted to a spark ignited engine and then adapted for fuelling with natural gas. After conversion work, general combustion characteristics of the gas engine(such as ignition delay, main and total combustion durations, and heat release characteristics) were studied as a functio of major engine operating variables such as air to fuel ratio, spark timing, and spark plug type. Some other studies on cyclic variation characteristics in IMEP, Pmax and (dp/dφ)max, and also optimum combustion phasing angle were performed.

  • PDF

Emergency Service Restoration and Load Balancing in Distribution Networks Using Feeder Loadings Balance Index (피더부하 균등화지수를 이용한 배전계통의 긴급정전복구 및 부하균등화)

  • Choe, Sang-Yeol;Jeong, Ho-Seong;Sin, Myeong-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.5
    • /
    • pp.217-224
    • /
    • 2002
  • This paper presents an algorithm to obtain an approximate optimal solution for the service restoration and load balancing of large scale radial distribution system in a real-time operation environment. Since the problem is formulated as a combinatorial optimization problem, it is difficult to solve a large-scale combinatorial optimization problem accurately within the reasonable computation time. Therefore, in order to find an approximate optimal solution quickly, the authors proposed an algorithm which combines optimization technique called cyclic best-first search with heuristic based feeder loadings balance index for computational efficiency and robust performance. To demonstrate the validity of the proposed algorithm, numerical calculations are carried out the KEPCO's 108 bus distribution system.

A Multi-mode LDPC Decoder for IEEE 802.16e Mobile WiMAX

  • Shin, Kyung-Wook;Kim, Hae-Ju
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.1
    • /
    • pp.24-33
    • /
    • 2012
  • This paper describes a multi-mode LDPC decoder which supports 19 block lengths and 6 code rates of Quasi-Cyclic LDPC code for Mobile WiMAX system. To achieve an efficient implementation of 114 operation modes, some design optimizations are considered including block-serial layered decoding scheme, a memory reduction technique based on the min-sum decoding algorithm and a novel method for generating the cyclic shift values of parity check matrix. From fixed-point simulations, decoding performance and optimal hardware parameters are analyzed. The designed LDPC decoder is verified by FPGA implementation, and synthesized with a $0.18-{\mu}m$ CMOS cell library. It has 380,000 gates and 52,992 bits RAM, and the estimated throughput is about 164 ~ 222 Mbps at 56 MHz@1.8 V.