• 제목/요약/키워드: Cut-Off Frequency

검색결과 405건 처리시간 0.027초

Basic RF Characteristics of Fishbone-Type Transmission Line Employing Comb-Type Ground Plane (FTLCGP) on PES Substrate for Use in Flexible Passive Circuits

  • Yun, Young;Jeong, Jang-Hyeon;Kim, Hong Seung;Jang, Nakwon
    • ETRI Journal
    • /
    • 제37권1호
    • /
    • pp.128-137
    • /
    • 2015
  • In this work, a fishbone-type transmission line employing a comb-type ground plane (FTLCGP) was fabricated on polyethersulfone (PES) substrate, and its RF characteristics were thoroughly investigated. According to the results, it was found that the FTLCGP on PES showed periodic capacitance values much higher than other types of transmission lines due to a coupling capacitance between the signal line and ground, which resulted in a reduction of wavelength and line width. Using the theoretical analysis, we also extracted the bandwidth characteristic of the FTLCGP on PES. According to the result, the FTLCGP structure showed a cut-off frequency of 280 GHz.

3상 부스트 컨버터의 제어기 최적 이득 설계 기법 (Optimal Gain Design Method of the 3 Phase Boost Converter)

  • 박해찬;김일송
    • 전력전자학회논문지
    • /
    • 제22권1호
    • /
    • pp.1-8
    • /
    • 2017
  • The optimal gain design method of a three-phase boost converter is proposed in this study. The control system has a two-loop configuration, in which each controller is coupled closely; thus, the optimal design is difficult to achieve using conventional gain-tuning method. The proposed method is adopted to the MATLAB SISO TOOL software and is based on the controller requirements, which are phase margin and cut-off frequency of the open-loop system. The optimal proportional -integral gains can be designed easily using the proposed interactive method of the SISO TOOL. The performance of the proposed system is verified through simulation and experiments.

인간형 로봇의 안정성을 위한 백래쉬 보상기 구현 (Implementation of Backlash Compensator for Stability of a Humanoid Robot)

  • 정병재;공정식;김진걸;허욱열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.681-683
    • /
    • 2004
  • This paper describes the control of a geared DC motor having a backlash for implementation of a humanoid robot using disturbance observer. Critical problem of the humanoid robot is caused by the nonlinearity such as a backlash. To meet this problem, a control method using disturbance observer has been proposed. The disturbance observer is designed to estimate the effects of nonlinearities in the system, to make the nonlinear system behave linearly. To design the low-pass filter in the disturbance observer, cut-off frequency of the output should be found. The goal of this paper is the implementation of the proposed system, compensating the backlash effect. To accomplish the goat, PD control and disturbance observer are employed to the system with no load and full load. As a result, system stability can be guaranteed by compensating the effect of backlash. In addition, real experiment shows the proposed control methodology will satisfy the stable working of a humanoid type in the future.

  • PDF

송전선 직렬보상을 이용한 순시전압강하 보상기 (Instantaneous Voltage Sag Corrector Using Series Compensator in Transfer Power Line Generator)

  • 이상훈;민완기;전병석;이대종;홍현문
    • 전기학회논문지P
    • /
    • 제55권1호
    • /
    • pp.21-25
    • /
    • 2006
  • This paper describes the novel control techniques design of VSC(Voltage Sag Corrector) for the purpose of power line quality enhancement. A fast detecting technique of voltage sag is implemented through the detection of instantaneous value on synchronous rotating do-reference frame. The first order digital filter is added in the detection algorithm to protect the insensitive characteristics against the noise. The relationship between the total detection time and cut-off frequency of the filter is described. The size of the capacitor bank used as the energy storage element is designed from the point of view of input/output energy with circuit analysis. Finally, the validity of the proposed scheme is proven through the simulated results.

새로운 고주파용 MOS 트랜지스터의 시작에 관한 연구 (Study on Experimental Fabrication of a New MOS Transistor for High Speed Device)

  • 성영권;민남기;성만영
    • 전기의세계
    • /
    • 제27권4호
    • /
    • pp.45-51
    • /
    • 1978
  • A new method of realizing the field effect transistor with a sub-.mu. channel width is described. The sub-.mu. channel width is made possible by etching grooves into n$^{+}$ pn$^{[-10]}$ n$^{[-10]}$ structure and using p region at the wall for the channel region of the Metal-Oxide-Semiconductor transistor (MOST), or by diffusing two different types of impurities through the same diffusion mask and using p region at the surface for the channel region of MOST. When the drain voltage is increased at the pn$^{[-10]}$ drainjunction the depletion layer extends into the n$^{[-10]}$ region instead of into p region; this is also the secret of success to realize the sub-.mu. channel width. As the result of the experimental fabrication, a microwave MOST was obtained. The cut-off frequency was calculated to be 15.4 GHz by Linvill's power equation using the measured capacitances and transconductance.

  • PDF

고조파 제거특성을 갖는 DGS형태의 CPW 저역통과 여파기의 설계 (A Design of Spurious-Reduced CPW Low-Pass Filter Based on Defected Ground Structure)

  • 노진원;진경민;황희용
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2005년도 종합학술발표회 논문집 Vol.15 No.1
    • /
    • pp.63-68
    • /
    • 2005
  • In this paper, Coplanar Waveguide(CPW) low-pass filter with the spurious-reduced is designed by using Defected Ground Structures(DGS). Two different LPF unit cells and DGS pattern are combined to reduce the spurious. In comparison to a conventional step impedance LPF, the size of proposed LPF as 17.2mm*6.8mm is several times smaller. The simulation and measurements confirm that spurious characteristics is presented less than -30dB($S_{21}$) to three times cut off frequency.

  • PDF

PPF 제어기법을 이용한 다중 모드 강제 진동의 능동 진동 제어 (Active Vibration Control of Multi-Mode Forced Vibration Using PPF Control Technique)

  • 한상보;곽문규;윤신일
    • 소음진동
    • /
    • 제7권6호
    • /
    • pp.1007-1013
    • /
    • 1997
  • This paper presents active vibration control scheme of multi-mode forced vibration using piezocetamic sensors and actuators. The control scheme adopted is the Positive Position Feedback (PPF) control. Among various vibration control techniques. PPF control technique makes use of generalized displacement measurements to accomplish the vibration suppression. Two independent controllers are implemented to control the first and the second modes of the beam under external excitation. Experimental results for various damping ratios and feedback gains of the PPF controllers are compared with respect to the contorl efficiency. The results indicate that steady state vibration under wide band excitation can be controlled effectively when multiple sets of PZT sensors and actuators were used with PPF control technique.

  • PDF

FCEV 블로워의 소음특성과 개선방향에 관한 연구 (A Study on the Noise Property and its Reduction of the FCEV Blower)

  • 오기석;이상권;서상훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1419-1424
    • /
    • 2007
  • Centrifugal turbo blower is requested highly efficiency and low noise in FCEV, but the noise generated by this machine causes of the most serious problems in the NVH performance. In general, centrifugal turbo blower is dominated by mechanical noise and aerodynamic noise. Mechanical noise is generated by rotation of the bearing, misalignment and unbalance. And aerodynamic noise is generated by the strong intersection between the flow discharged from the impeller and the cut-off in the casing. The first object of this study is to comprehend a noise property of the blower through the noise test. And, second object is to bring up the method that can reduce blower noise.

  • PDF

New Permanent Magnet Synchronous Motor Current Sensing Phase Delay Compensation Method

  • Park, Sei-Hun;Kim, Il-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.241-246
    • /
    • 2016
  • This paper presents a method that can improve the performance of permanent magnet synchronous motor current control by minimizing the measured current phase delay caused by the Low Pass Filter(LPF) used to cut off the noises that flowed in when feedback currents are measured. Although existing methods that change the Cutoff Frequency of the LPF can minimize phase delays during high speed rotations, their noise cutoff effects are much lower and this may lead to the decline of control performance. Therefore, in this study, an algorithm that can compensate current phase delays through relatively simple calculations from the synchronous motor d-q axis coordinate transformation matrix and the inverse transformation matrix is proposed and the validity of the proposed method is verified by comparing the waveform of the calculated current with the waveform of actual currents through simulations and experiments.

파라메타 각 변화를 고려한 힌지없는 헬리콥터 로우터의 공력탄성학적 안정성 (The Study on the Aeroelastic Stability of Hingeless Helicopter Rotor in Hover Considering Parametric Angle Changes)

  • 한창헌;김승조
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.386-391
    • /
    • 1998
  • The effect of the changes in parameter angles(precone, droop, sweep) on the lead-lag damping was focused on. Experiment was made with hingeless 4-blade rotors and NACA 0012 airfoil. For the measurement of the rotating natural frequencies and lead-lag damping, non-rotating swash plate was oscillated at the regressing lag mode frequency and the data were acquired after the excitation was cut off. Analysis was made using a finite element formulation based on Hamilton's principle. The main blade is assumed as elastic beams. Quasi-steady strip theory is used to obtain aerodynamic forces, and non-circulatory forces are also included.

  • PDF