• 제목/요약/키워드: Customized implant

검색결과 97건 처리시간 0.025초

티타늄 및 PEEK 지대주 소재가 임플란트 유지 수복물 및 주위 지지골 응력 분포에 미치는 영향: 3차원 유한요소해석 (Effects of titanium and PEEK abutments on implant-supported dental prosthesis and stress distribution of surrounding bones: three-dimensional finite element analysis)

  • 홍민호
    • 대한치과기공학회지
    • /
    • 제44권3호
    • /
    • pp.67-75
    • /
    • 2022
  • Purpose: This study aimed to comparatively evaluate the stress distribution of bones surrounding the implant system to which both titanium and polyetheretherketone (PEEK) abutments are applied using a three-dimensional finite element analysis. Methods: The three-dimensional implant system was designed by the computer-aided design program (CATIA; Dassault Systemes). The discretization process for setting nodes and elements was conducted using the HyperMesh program (Altair), after finishing the design of each structure for the customized abutment implant system. The results of the stress analysis were drawn from the Abaqus program (Dassault Systèmes). This study applied 200 N of vertical load and 100 N of oblique load to the occlusal surface of a mandibular first molar. Results: Under external load application, the PEEK-modeled dental implant showed the highest von Mises stress (VMS). The lowest VMS was observed in the Ti-modeled abutment screws. In all groups, the VMS was observed in the crestal regions or necks of implants. Conclusion: The bones surrounding the implant system to which the PEEK abutment was applied, such as the cortical and trabecular bones, showed stress distribution similar to that of the titanium implant system. This finding suggests that the difference in the abutment materials had no effect on the stress distribution of the bones surrounding implants. However, the PEEK abutments require mechanical and physical properties improved for clinical application, and the clinical application is thought to be limited.

Recent advances in dental implants

  • Hong, Do Gia Khang;Oh, Ji-hyeon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제39권
    • /
    • pp.33.1-33.10
    • /
    • 2017
  • Dental implants are a common treatment for the loss of teeth. This paper summarizes current knowledge on implant surfaces, immediate loading versus conventional loading, short implants, sinus lifting, and custom implants using three-dimensional printing. Most of the implant surface modifications showed good osseointegration results. Regarding biomolecular coatings, which have been recently developed and studied, good results were observed in animal experiments. Immediate loading had similar clinical outcomes compared to conventional loading and can be used as a successful treatment because it has the advantage of reducing treatment times and providing early function and aesthetics. Short implants showed similar clinical outcomes compared to standard implants. A variety of sinus augmentation techniques, grafting materials, and alternative techniques, such as tilted implants, zygomatic implants, and short implants, can be used. With the development of new technologies in three-dimension and computer-aided design/computer-aided manufacturing (CAD/CAM) customized implants can be used as an alternative to conventional implant designs. However, there are limitations due to the lack of long-term studies or clinical studies. A long-term clinical trial and a more predictive study are needed.

Periodontal tissue reaction to customized nano-hydroxyapatite block scaffold in one-wall intrabony defect: a histologic study in dogs

  • Lee, Jung-Seok;Park, Weon-Yeong;Cha, Jae-Kook;Jung, Ui-Won;Kim, Chang-Sung;Lee, Yong-Keun;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • 제42권2호
    • /
    • pp.50-58
    • /
    • 2012
  • Purpose: This study evaluated histologically the tissue responses to and the effects of a customized nano-hydroxyapatite (n-HA) block bone graft on periodontal regeneration in a one-wall periodontal-defect model. Methods: A customized block bone for filling in the standardized periodontal defect was fabricated from prefabricated n-HA powders and a polymeric sponge. Bilateral $4{\times}{\times}4{\times}5$ mm (buccolingual width${\times}$mesiodistal width${\times}$depth), one-wall, critical-size intrabony periodontal defects were surgically created at the mandibular second and fourth premolars of five Beagle dogs. In each dog, one defect was filled with block-type HA and the other served as a sham-surgery control. The animals were sacrificed following an 8-week healing interval for clinical and histological evaluations. Results: Although the sites that received an n-HA block showed minimal bone formation, the n-HA block was maintained within the defect with its original hexahedral shape. In addition, only a limited inflammatory reaction was observed at sites that received an n-HA block, which might have been due to the high stability of the customized block bone. Conclusions: In the limitation of this study, customized n-HA block could provide a space for periodontal tissue engineering, with minimal inflammation.

Cervical spine reconstruction after total vertebrectomy using customized three-dimensional-printed implants in dogs

  • Ji-Won Jeon;Kyu-Won Kang;Woo-Keyoung Kim;Sook Yang;Byung-Jae Kang
    • Journal of Veterinary Science
    • /
    • 제25권1호
    • /
    • pp.2.1-2.14
    • /
    • 2024
  • Background: Sufficient surgical resection is necessary for effective tumor control, but is usually limited for vertebral tumors, especially in the cervical spine in small animal neurosurgery. Objective: To evaluate the primary stability and safety of customized three-dimensional (3D)-printed implants for cervical spine reconstruction after total vertebrectomy. Methods: Customized guides and implants were designed based on computed tomography (CT) imaging of five beagle cadavers and were 3D-printed. They were used to reconstruct C5 after total vertebrectomy. Postoperative CT images were obtained to evaluate the safety and accuracy of screw positioning. After harvesting 10 vertebral specimens (C3-C7) from intact (group A) and implanted spines (group B), implant stability was analyzed using a 4-point bending test comparing with groups A and C (reconstituted with plate and pins/polymethylmethacrylate after testing in Group A). Results: All customized implants were applied without gross neurovascular damage. In addition, 90% of the screws were in a safe area, with 7.5% in grade 1 (< 1.3 mm) and 2.5% in grade 2 (> 1.3 mm). The mean entry point and angular deviations were 0.81 ± 0.43 mm and 6.50 ± 5.11°, respectively. Groups B and C significantly decreased the range of motion (ROM) in C3-C7 compared with intact spines (p = 0.033, and 0.018). Both groups reduced overall ROM and neutral zone in C4-C6, but only group B showed significance (p = 0.005, and 0.027). Conclusion: Customized 3D-printed implants could safely and accurately replace a cervical vertebra in dog cadavers while providing primary stability.

무절개 수술을 이용한 맞춤형 지르코니아 지대주의 즉시 장착 증례 (Immediate Connection of Customized Zirconia Abutment Using Flapless Guided Surgery: A Clinical Report)

  • 이경제;최병호;김희준;정승미
    • 구강회복응용과학지
    • /
    • 제28권2호
    • /
    • pp.201-212
    • /
    • 2012
  • 임플란트 주위조직과 치아 주위조직은 조직학, 형태학적으로 유사한 면이 있다. 특히 functional ankylosis라 불리는 티타늄과 연조직의 직접적인 상피부착은 치아주위 조직의 접합상피처럼 염증세포의 치근단으로의 이행 및 그로 인한 골흡수를 막는 역할을 한다. 그러나 반복적인 지대주의 착탈은 임플란트 주위 연조직의 mucosal barrier를 파괴하여 골흡수를 야기할 수 있다. 만일 지대주의 반복적인 착탈 없이 수술 시에 보철 지대주를 채결한다면 골흡수의 양을 줄일 수 있을 것이다. 이는 기존의 수술방법으로는 한계가 있었으나 Cone Beam Computed Tomography(CBCT)를 이용한 guided surgery를 이용함으로써 임플란트 식립의 3차원적 정확성의 비약적인 향상으로 이런 술식이 가능하게 되었다. 본 증례는 정밀한 CBCT를 통한 분석 후 지르코니아 맞춤 지대주를 미리 제작하고 수술 시에 즉시 지대주와 임시보철물을 연결한 경우로 임상적으로 만족할만한 결과를 얻어 이를 보고하는 바이다.

컴퓨터 시뮬레이션을 이용한 임플란트 상부 티타늄 구조물의 주조방안 (CONFUTER-AIDED CASTING DESIGN FOR IMPLANT TITANIUM SUPERSTRUCTURES)

  • 오세욱;이호용;이근우;심준성
    • 대한치과보철학회지
    • /
    • 제41권4호
    • /
    • pp.421-439
    • /
    • 2003
  • Statement of problem : It is difficult to obtain a good titanium casting body using the traditional sprue design because of high melting point of Ti, and the low fluidity and high reactivity of molten Ti. Purpose : A new sprue design for titanium casting bodies needs more trial and error. In order to decrease the number of trial and error, computer simulation(MAGMASOFT, Magmasoft Giessereitechnologie GmbH, Achen, Germany) was used to optimize sprue design in U-shaped implant superstructures. Material and method : Five kinds of sprue were examined for the design of the sprue former for titanium casting: Sprue design A(sprue length 4 mm, rectangular shape, 4 sprues), Sprue design B(sprue length 4 mm. round shape. radius 2 mm, 7 sprues), Sprue design C (sprue length 2 mm, round shape, radius 2 mm, 7 sprues). Sprue design D (sprue length 2 mm, cone shape, large radius 3mm. small radius 2mm, 7 sprues), and Sprue design E( sprue length 2 mm. one unit channel shape). Sprue design F(sprue length 2mm, one unit channel shape) was also examined for the design of the customized sprue former in the Biotan system(Schutz Dental Gmbh, Germany). The casting bodies were taken in Sprue design A, Sprue design D, Sprue design E, and Sprue design F in the Biotan casting system. The numerically predicted defects were compared with the experimental dental castings by the radiographic and sectional view observations. Results : 1. According to the result of computer simulation, turbulence during mold filling was decreased in the sequence of Sprue design F, Sprue design E, Sprue design D, Sprue design C, Sprue design B, and Sprue design A. 2. The calculated solidification time contours indicate that hot spot was moved from the casting body to the sprue button in the sequence of Sprue design A, Sprue design B, Sprue design C, Sprue design D, and Sprue design E. The filling pattern of Sprue design F was similar to that of Sprue design E. 3 The predicted filling pattern shows that less turbulence was found in the customized sprue former than in the standard sprue former. 4. According to the results of the radiographic and cross sectional observations, casting defects less than 1mm were found at the center of a casting body with Sprue design E and Sprue design F. However, larger casting defects of 4mm were found in a casting with Sprue design A. 5. The predicted casting porosity was similar to that of the real casting. Conclusion : One unit channel-type and customized sprue former can be recommended. Further research and developement of various sprue designs using computer simulation in necessary to optimize casting design, in order to reduce the formation of casting defects in implant titanuim super-structures.

Influence of preparation depths on the fracture load of customized zirconia abutments with titanium insert

  • Joo, Han-Sung;Yang, Hong-So;Park, Sang-Won;Kim, Hyun-Seung;Yun, Kwi-Dug;Ji, Min-Kyung;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권3호
    • /
    • pp.183-190
    • /
    • 2015
  • PURPOSE. This study evaluated the fracture load of customized zirconia abutments with titanium insert according to preparation depths, with or without 5-year artificial aging. MATERIALS AND METHODS. Thirty-six identical lithium disilicate crowns (IPS e.max press) were fabricated to replace a maxillary right central incisor and cemented to the customized zirconia abutment with titanium insert on a $4.5{\times}10$ mm titanium fixture. Abutments were fabricated with 3 preparation depths (0.5 mm, 0.7 mm, and 0.9 mm). Half of the samples were then processed using thermocycling (temperature: $5-55^{\circ}C$, dwelling time: 120s) and chewing simulation (1,200,000 cycles, 49 N load). All specimens were classified into 6 groups depending on the preparation depth and artificial aging (non-artificial aging groups: N5, N7, N9; artificial aging groups: A5, A7, A9). Static load was applied at 135 degrees to the implant axis in a universal testing machine. Statistical analyses of the results were performed using 1-way ANOVA, 2-way ANOVA, independent t-test and multiple linear regression. RESULTS. The fracture loads were $539.28{\pm}63.11$ N (N5), $406.56{\pm}28.94$ N (N7), $366.66{\pm}30.19$ N (N9), $392.61{\pm}50.57$ N (A5), $317.94{\pm}30.05$ N (A7), and $292.74{\pm}37.15$ N (A9). The fracture load of group N5 was significantly higher than those of group N7 and N9 (P<.017). Consequently, the fracture load of group A5 was also significantly higher than those of group A7 and A9 (P<.05). After artificial aging, the fracture load was significantly decreased in all groups with various preparation depths (P<.05). CONCLUSION. The fracture load of a single anterior implant restored with lithium disilicate crown on zirconia abutment with titanium insert differed depending on the preparation depths. After 5-year artificial aging, the fracture loads of all preparation groups decreased significantly.

임플란트 환자의 잇솔질 교육경험에 따른 유지관리행태 연구 (Study of maintenance behavior based on the experience of the tooth brushing instruction for implant patient)

  • 전지현;민희홍
    • 한국치위생학회지
    • /
    • 제13권3호
    • /
    • pp.403-410
    • /
    • 2013
  • Objectives : This study aims to provide the basic data for the maintenance and management of healthy implants through finding out the educational experience of toothbrushing and the oral hygiene management for the implant patients and to determine the maintenance measure. Methods : From April 1 to october 1, 2012, 250 patients in the dental clinic in Daejeon completed the self-reported questionnaire. Results : As for the educational experience of toothbrushing, 66.4 percent received the training for toothbrushing and 33.6 percent had not received the training for toothbrushing. Those who brushed three times a day accounted for 74.1 percent. Those who received the training for toothbrushing comprised 56.0 percent and took regular check up of every 6 months. Approximately 50.0% received regular scaling service every 6 months. Periodical medical check up comprised 55.6% among those who received toothbrushing education. Approximately 63.9% thought that periodical medical check up is the most important to maintain oral health. Conclusions : There were important factors for oral health. They were tooth-brushing, the utilization of various oral hygienic products, and the awareness of importance of oral hygiene management. The customized education program for the general public should be implemented as regular as possible.

부분 무치악 환자에서 마그네슘 이온주입 임플란트의 성공률에 대한 전향적 임상연구 (The success rate of Mg-incorporated oxidized implants in partially edentulous patients: a prospective clinical study)

  • 최수정;유정호;이규복;김진욱
    • 대한치과보철학회지
    • /
    • 제50권3호
    • /
    • pp.176-183
    • /
    • 2012
  • 연구 목적: 부분 무치악 환자에서 Mg titanate implant (M Implant system, Shinhung, Korea)의보철 후 1년간의 방사선사진을 이용한 변연골 흡수량과 Osstell$^{(R)}$을 이용한 임플란트 안정성 평가 결과를 분석하여 임상적인 성공률에 대해 알아보고자 한다. 연구 재료 및 방법: 38명의 환자에 79개의 임플란트를 식립하여 보철 후 1년 동안 변연골 흡수량, 임플란트의 동요도, 임플란트 식립 위치에 따른 분포 및 성공률, 보철 전후에 따른 성공률을 분석했다. 결과: 변연골의 흡수량은 보철물 장착 후 1년간의 평가에서 상악에서는 평균 1.537 mm, 하악에서는 평균 1.172 mm의 변연골 흡수가 관찰되었으며, 전체적인 상하악의 평균 변연골 흡수량은 1.255 mm로 관찰되었다. 수술 후 시간이 경과함에 따라 ISQ값은 미약하게 감소하였다가 증가하는 경향을 보였으나, 상악과 하악 모두에서 식립 당일 이후 예비 인상일, 최종 보철물의 장착일과 주기적인 평가 기간 동안 ISQ값의 큰 증가나 감소를 나타내지는 않았다. 성공률은 상악에서의 94.12%였고, 하악에서의 98.39%였다. 결론: 본 실험의 결과로 미루어 Mg titanate implant는 임상적으로 양호한 결과를 보여주었다.