• 제목/요약/키워드: Curve characterization

검색결과 213건 처리시간 0.026초

Characterization of Tensile Energy Aborption in Paper

  • Park, Jong-Moon;James L. Thorpe
    • 펄프종이기술
    • /
    • 제31권5호
    • /
    • pp.47-56
    • /
    • 1999
  • Tensile energy absorption in paper has long been measured as the area under the load-elongation curve. Little effort has been made to define where and how that energy is used within the paper itself. Characterization of tensile energy absorption in paper is discussed. Multiple small elements within newsprint and kraft sack have been defined and the energy absorbed in those elements are discussed. The tensile profiles of the weak paper, newsprint, and the tough paper, kraft sack, are presented as separate strain profiles, stress profiles, and strain energy density profiles. This allows a complete analysis of the energy absorption of both papers for comparison or contrast.

  • PDF

유도 초음파를 이용한 락 플레이트 물성 평가 (Material Characterization of Lock Plate Using Guided Wave)

  • 이재선;조윤호;정경식
    • 대한기계학회논문집A
    • /
    • 제33권4호
    • /
    • pp.373-379
    • /
    • 2009
  • Presented in this paper is a new experimental technique to measure material properties of lock plate of gas turbine plants by using ultrasonic guided wave. In comparison with the mechanical destructive testings, material characterization of the Inconel x-750 was nondestructively carried out in a more efficient manner to discriminate the change in elastic moduli and the poisson's ratio attributed to the variation of heat treatment condition. The proposed technique shows a satisfactory feasibility via the comparative experiments with the imported lock plate specimens. It is also expected that the guided wave technique can cover a longer and wider range as a new cost-&-time-saving inspection tool due to the interaction with a greater part of specimen, compared to a conventional local point-by-point scheme.

6H-SiC 위에 형성한 에피택시 AIN 박막 구조에 대한 전기적 특성의 평가온도 의존성 (Temperature Dependence on Electrical Characterization of Epitaxially Grown AIN film on 6H-SiC Structures)

  • 김용성;김광호
    • 한국전기전자재료학회논문지
    • /
    • 제19권1호
    • /
    • pp.18-22
    • /
    • 2006
  • Epitaxial aluminum nitride films on 6H-SiC (0001) were fabricated using reactive RF magnetron sputtering and post-deposition rapid thermal annealing. The electrical properties of AIN films depending on film thickness and measurement temperature have been observed. Full width at half maximum of AIN (0002) was $0.1204^{\circ}$ (about 430 arcsec) X-ray rocking curve results. The equivalent oxide thickness (EOT) of AIN film was estimated as about 10 nm and the leakage current density was within the order of $10^{-8} 4/cm^2$. The dielectric constant of AIN film estimated from the accumulation region of C-V curve measured at $300^{\circ}C$ was 8.3. The dynamic dielectric constant was obtained as 5.1 from J vs. 1/T plots at the temperature ranging from R.T. to $300^{\circ}C$ From above, estimation temperature dependance of the electrical properties of Al/AIN/SiC MIS devices was affirmed and useful data compilation for the reliabilities of SiC MIS is expected.

램파모드의 시간-주파수 해석 (Time-Frequency Analysis of Lamb wave mode)

  • 박익근;안형근
    • 한국공작기계학회논문집
    • /
    • 제10권1호
    • /
    • pp.133-140
    • /
    • 2001
  • Recently, to assure the integrity of a structural components such as piping pressure vessels and thinning structure, Lamb wave inspection technique has been used in material evaluation. It is very important to select the optimal Lamb wave mode and to analyze the signal accurately because of its unique dispersion properties grnerating several modes within the speci-men. It this study, the feasibility of material evaluation applications using wavelet analysis of Lamb wave has been veir-fied experimentally. These results show as follows; 1)dispersion characteristic of each mode in dispersion curve is demon-strated that A0 mode propagating material surface is useful mode having the lest energy loss and not sensitive to surface condition. 2) it can be detected even the micro defect ($1\times2mm$) fabricated in ultrasonic probe flaw distance (290mm) to axis direction. 3) the wavelet transform which is called "time-frequency analysis" shows the Lamb wave propagation due to the change of materials characterization can be evaluated at each frequency and experimental group velocity of Lamb wave agrees quite well with that of simulated dispersion curve.ion curve.

  • PDF

Fabrication and Characterization of High Temperature Electrostatic Chucks

  • Bang, Jae-Cheol
    • The Korean Journal of Ceramics
    • /
    • 제5권1호
    • /
    • pp.87-90
    • /
    • 1999
  • It was suggested that tape casting method can be used to fabricate high-temperature electrostatic chucks(HTESC) based on a metal substrate coated with a glass-ceramic insulating layer. The adhesion of the coating was excellent such that it was able to withstand temperature cycling to over $300^{\circ}C$ without spalling. The electrostatic clamping pressure reached a very high value of about 9 torr at 600V and generally followed the theoretical voltage-squared curve. Based on these results, we believe that we successfully developed a viable technique for manufacturing low cost HTESC.

  • PDF

Determination of the Size Distribution of Magnetite Nanoparticles from Magnetic Measurements

  • Yoon, Sung-Hyun
    • Journal of Magnetics
    • /
    • 제16권4호
    • /
    • pp.368-373
    • /
    • 2011
  • Particle size distributions in 10 nm magnetite ferrofluids are analyzed based on both dc and ac magnetic measurements. Modified log-normal distributions are used for fitting the experimental results, which allows for a proper account of the narrow distributions. The calculated average particle sizes are in good agreement with the TEM results. However the ac method gives a much narrower distribution width than that of the dc magnetization curve fit. The proposed measurements combined with the analysis methods are useful for the characterization of ferrofluids being considered for biomedical applications.

NEW VERSION OF THE MAGNETIC CURVES ACCORDING TO THE BISHOP FRAME IN 𝔼3

  • Sariaydin, Muhammed T.;Korpinar, Talat
    • 호남수학학술지
    • /
    • 제41권1호
    • /
    • pp.175-183
    • /
    • 2019
  • In this paper, it is investigated Lorentz force equations for $N_1$ and $N_2$-magnetic curves in 3-Dimensional Euclidean space. We give the Lorentz force in the Bishop frame in ${\mathbb{E}}^3$. Then, we obtain a new characterization for a magnetic field V. Also, we also give examples for each curve.

모바일 폰의 카메라와 LCD 모듈간의 RGB 참조표에 기반한 색 정합의 구현 (Implementation of the Color Matching Between Mobile Camera and Mobile LCD Based on RGB LUT)

  • 손창환;박기현;이철희;하영호
    • 대한전자공학회논문지SP
    • /
    • 제43권3호
    • /
    • pp.25-33
    • /
    • 2006
  • 본 논문에서는 모바일 카메라와 모바일 LCD 간의 컬러 충실도를 높이기 위한 3차원 RGB 참조표에 기반한 장치 독립적인 색 정합 방법을 제안하였다. 제안한 색 정합 방법은 크게 모바일 디스플레이(LCD) 및 카메라의 장치 특성화, 색역 사상, 대표색에 기반한 3차원 참조표 설계로 구성된다. 먼저, 모바일 디스플레이의 장치 특성화 과정은 전기-빛 입출력의 특성으로부터 기존의 CRT 모니터에 적용된 GOG(Gai Offset Gamma) 모델이나 LCD 모니터에 적용된 S-curve 모델과는 다른, Sigmoidal 함수를 사용해서 모델링되었고, 모바일 카메라의 장치 특성화는 표준(D65)환경하에서 촬영된 컬러 차트의 디지털 값(RGB)과 표준 색 자극치 데이터(CIELAB, CIEXYZ)를 다항 회귀 방정식에 대입해서 모델링되었다. 그리고 다항 회귀 방정식으로부터 획득된 표준 색 자극치 데이터는 카메라 장치 특성화 모델링의 특성으로 인해 표준 색 공간의 최대 값을 초과할 수 있기 때문에, 선형적인 채도와 밝기 압축 과정을 통하여 보정되었다. 마지막으로, 표준 환경하에서의 모바일 카메라의 색역과 모바일 디스플레이 장치의 색역의 차이를 보상하기 위해, 경계면 설정과 다중-닻 점 색역 사상 기법이 수행되었다. 이러한 장치 독립적인 색 정합 처리 과정을 실시간으로 구현하기 위해 대표색에 기반한 3차원 참조표를 설계하여, 참조표에 기반한 장치 독립적인 색 재현의 정량적인 화질을 평가하고, 기존의 장치 의존적인 방법과 성능을 비교 분석하였다.

Integrated approach using well data and seismic attributes for reservoir characterization

  • Kim Ji- Yeong;Lim Jong-Se;Shin Sung-Ryul
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
    • /
    • pp.723-730
    • /
    • 2003
  • In general, well log and core data have been utilized for reservoir characterization. These well data can provide valuable information on reservoir properties with high vertical resolution at well locations. While the seismic surveys cover large areas of field but give only indirect features about reservoir properties. Therefore it is possible to estimate the reservoir properties guided by seismic data on entire area if a relationship of seismic data and well data can be defined. Seismic attributes calculated from seismic surveys contain the particular reservoir features, so that they should be extracted and used properly according to the purpose of study. The method to select the suitable seismic attributes among enormous ones is needed. The stepwise regression and fuzzy curve analysis based on fuzzy logics are used for selecting the best attributes. The relationship can be utilized to estimate reservoir properties derived from seismic attributes. This methodology is applied to a synthetic seismogram and a sonic log acquired from velocity model. Seismic attributes calculated from the seismic data are reflection strength, instantaneous phase, instantaneous frequency and pseudo sonic logging data as well as seismic trace. The fuzzy curve analysis is used for choosing the best seismic attributes compared to sonic log as well data, so that seismic trace, reflection strength, instantaneous frequency, and pseudo sonic logging data are selected. The relationship between the seismic attribute and well data is found out by the statistical regression method and estimates the reliable well data at a specific field location derived from only seismic attributes. For a future work in this study, the methodology should be checked an applicability of the real fields with more complex and various reservoir features.

  • PDF

흑천의 유량조건별 오염부하량 특성 (Pollutant Load Characterization with Flow Conditions in Heukcheon Stream)

  • 최경완;이상원;노창완;이재관;이영준
    • 상하수도학회지
    • /
    • 제29권5호
    • /
    • pp.551-557
    • /
    • 2015
  • The TMDL (Total Maximum Daily Load) has been used to determine the water quality target. LDC (Load Duration Curve) based on hydrology has been used to support water quality assessments and development of TMDL. Also FDC (Flow Duration Curve) analysis can be used as a general indicator of hydrologic condition. The LDC is developed by multiplying FDC with the numeric water quality target of the factor for the pollutant of concern. Therefore, this study was to create LDC using the stream flow data and numeric water quality target of BOD and T-P in order to evaluate the pollutant load characterization by flow conditions in Heukcheon stream. When it is to be a high-flows condition, BOD and T-P are necessary to manage. BOD and T-P did not satisfy the numeric water quality target for both seasons (spring and summer). In order to meet the numeric water quality target in Heukcheon stream, management of non point source pollutant is much more important than that of point source pollutant control.