전향보상 전압의 위상 변화를 통한 단독운전 검출 방법의 계통 정상 상태의 성능 평가 (Performance Evaluation of Islanding Detection Method by Phase Shifted Feed-Forward Voltage in Steady-State Grid Condition)

  • 김동욱;김성민
    • 전력전자학회논문지
    • /
    • 제23권6호
    • /
    • pp.373-380
    • /
    • 2018
  • This study proposes a new islanding detection method that uses the phase shift of feed-forward voltage and evaluates the performance of an existing method and the proposed method when the grid frequency changes within the allowable range under steady-state conditions. The investigated existing method, which is slip mode frequency shift (SMS), uses current phase shift to detect islanding. The SMS method supplies reactive current to the grid under this condition, but the proposed method does not generate additional reactive power because it does not depend on the current control loop. The performance in steady-state grid condition is evaluated through simulations and experiments.

3레벨 태양광 PCS에서의 누설전류 저감기법 개발 (Development of Leakage Current Reduction Method in 3-Level Photovoltaic PCS)

  • 한성은;조종민;안현성;차한주
    • 전력전자학회논문지
    • /
    • 제24권1호
    • /
    • pp.56-61
    • /
    • 2019
  • In this study, a reduction method of leakage current in a three-level photovoltaic power-conditioning system (PCS) is proposed and verified by simulation and experiment. Leakage current generation is analyzed through an equivalent model of the common mode voltage considering a significant parasitic capacitance existing between the photovoltaic array and ground. A leakage current reduction method using pulse-width modulation (PWM) method is also proposed, and a 10-kW three-level photovoltaic PCS simulation and experiment is performed with a $1{\mu}F$ parasitic capacitor based on 100 nF/kW. The proposed method using the PWM method is verified to reduce the leakage current by 73% compared with the conventional PWM method.

점호각을 고려한 유도전동기의 소프트 기동 특성 해석 (Analysis of Soft Start-up Characteristics of the Induction Motor Considering the Firing Angle)

  • 김종겸;박영진
    • 전기학회논문지
    • /
    • 제65권6호
    • /
    • pp.1007-1012
    • /
    • 2016
  • Induction motors are used widely in driving load of a fluid, such as a pump or a fan in the industry. Induction motor has been generated the voltage drop by the occurrence of a high current during startup. In addition, high start-up current can act as a mechanical stress on the shaft of the motor. So there is need a way to reduce the starting current. Soft start method is one of the many ways to reduce the starting current. This method uses silicon-controlled rectifiers(SCRs) for varying value of the voltage applied to the motor. There is a case for fixing or changing the thyristor firing angle to adjust the magnitude of the voltage. Starting power factor of induction motor is very low compared to the normal operation. Soft starting with the firing angle fixed needs to be considered a low power factor at startup. In this study, we compared the direct start characteristics and soft start characteristics considering the low power factor at the time of start-up. It was possible to confirm that the starting current and the voltage drop is present differently according to the firing angle.

STATCOM에서 영상분 전류주입에 의한 셀간 전압평형화 제어의 향상 (Enhancement of Cell Voltage Balancing Control by Zero Sequence Current Injection in a Cascaded H-Bridge STATCOM)

  • 권병기;정승기;김태형
    • 전력전자학회논문지
    • /
    • 제20권4호
    • /
    • pp.321-329
    • /
    • 2015
  • The static synchronous compensator (STATCOM) of cascaded H-bridge configuration accompanying multiple separate DC sides is inherently subject to the problem of uneven DC voltages. These DC voltages in one leg can be controlled by adjusting the AC-side output voltage of each cell inverter, which is proportional to the active power. However, when the phase current is extremely small, large AC-side voltage is required to generate the active power to balance the cell voltages. In this study, an alternative zero-sequence current injection method is proposed, which facilitates effective cell balancing controllers at no load, and has no effect on the power grid because the injected zero sequence current only flows within the STATCOM delta circuit. The performance of the proposed method is verified through simulation and experiments.

Voltage control of three phase rectifier with current-controlled voltage type converter

  • 우명호;정승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 추계학술대회 논문집 학회본부
    • /
    • pp.207-209
    • /
    • 1991
  • This paper deals with voltage control method of PWM rectifier using current-controlled voltage type converter. A linearized model of the current-controlled rectifier is derived, which is used to examine the effect of controller gains to its dynamic responses. Through the simulation, it is shown that the proposed model is generally valid, which is confirmed by experimental results.

  • PDF

Individual DC Voltage Balancing Method at Zero Current Mode for Cascaded H-bridge Based Static Synchronous Compensator

  • Yang, Zezhou;Sun, Jianjun;Li, Shangsheng;Liao, Zhiqiang;Zha, Xiaoming
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.240-249
    • /
    • 2018
  • Individual DC voltage balance problem is an inherent issue for cascaded H-bridge (CHB) based converter. When the CHB-based static synchronous compensator (STATCOM) is operating at zero current mode, the software-based individual DC voltage balancing control techniques may not work because of the infinitesimal output current. However, the different power losses of each cell would lead to the individual DC voltages unbalance. The uneven power losses on the local supplied cell-controllers (including the control circuit and drive circuit) would especially cause the divergence of individual DC voltages, due to their characteristic as constant power loads. To solve this problem, this paper proposes an adaptive voltage balancing module which is designed in the cell-controller board with small size and low cost circuits. It is controlled to make the power loss of the cell a constant resistance load, thus the DC voltages are balanced in zero current mode. Field test in a 10kV STATCOM confirms the performance of the proposed method.

Short-circuit Protection for the Series-Connected Switches in High Voltage Applications

  • Tu Vo, Nguyen Qui;Choi, Hyun-Chul;Lee, Chang-Hee
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1298-1305
    • /
    • 2016
  • This paper presents the development of a short-circuit protection mechanism on a high voltage switch (HVS) board which is built by a series connection of semiconductor switches. The HVS board is able to quickly detect and limit the peak fault current before the signal board triggers off a gate signal. Voltage clamping techniques are used to safely turn off the short-circuit current and to prevent overvoltage of the series-connected switches. The selection method of the main devices and the development of the HVS board are described in detail. Experimental results have demonstrated that the HVS board is capable of withstanding a short-circuit current at a rated voltage of 10kV without a di/dt slowing down inductor. The corresponding short-circuit current is restricted to 125 A within 100 ns and can safely turn off within 120 ns.

승압용 커패시터를 이용한 단상 배전압 AC-DC 컨버터 (The Single-Phase Voltage-Doubler AC-DC Converter by using a Boost Capacitor)

  • 정상화;김상돈;이수흠;이현우;전중함;정기환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1103-1105
    • /
    • 2002
  • A conventional AC-DC boost converter has much variation of input current as more increased the load or output voltage by the hysterical control method that is comparing area of current pulse by using PWM method and integration to sinusoidal input current. To improve the problems. in this paper, we propose the single-phase voltage doubler AC-DC converter circuit using the capacitor for boost:confirm characteristics of normal and transition state by using simulation, be stabilized voltage of doubler capacitor for boost, and Identify to get the sinusoidal input current with unity power factor.

  • PDF

통계적 방법에 의한 전자레인지의 돌입전류 최적화 연구 (A Study on Optimum control for Inrush current of Microwave Oven using Statistical Method)

  • 이민기;고강훈;권순걸;이현우
    • 조명전기설비학회논문지
    • /
    • 제15권5호
    • /
    • pp.61-67
    • /
    • 2001
  • 여자자속의 포화는 전자레인지에 사용되는 고압 변압기의 초기 입력 전원의 위상에 의존한다. 고압트랜스의 돌입전류를 제한하기 위해서는 릴레이의 접점을 입력전원위상의 최저점일 때 ˝ON˝하여야 한다. 개선된 회로는 보정된 인터럽터 신호를 마이컴의 입력으로서 릴레이의 접점이 돌입전류가 최소 일 때 ˝ON˝한다. 실험결과는 입력전압변동모드에 대해서 개선된 회로가 설계목표치 50[A]를 만족함을 나타내었다. 그리고 통계적 기법으로서 이를 검증한다.

  • PDF

계통연계형 인버터의 왜곡된 계통전압에 의해 발생하는 전류고조파 저감방법 (Reduction Method of Harmonic Current by Distorted Grid Voltage in the Grid-connected Inverter)

  • 목형수;최규하;이정민;김상훈;지준근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.108-111
    • /
    • 2007
  • Phase angle in grid-connected inverter is important information for current control. When different loads are connected to PCC(Point of Common Coupling) of grid, distorted grid voltage is taken place by load utility generating distorted current. Especially, in case the grid voltage is distorted by low order frequency such as $3^{rd}$, $5^{th}$ harmonic, phase angle of PLL output is distorted. This paper analyze problem of current THD(Total Harmonic Distortion) due to distorted phase angle by distorted grid voltage, and propose control method compensating this problem. Also, it‘s validity is verified by simulation and experiment.