• 제목/요약/키워드: Current-Mode Circuit

검색결과 642건 처리시간 0.026초

전류제어형 DC-DC컨버터의 안정도 향상에 관한 연구 (A Study on the stability improvement of current-mode controlled DC-DC Converter)

  • 김철진;송요창
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.365-367
    • /
    • 2000
  • Recently, the power supply equipments have tendency to take multiple feedback loop paths. In this paper, the state space averaging technique is applied for the analysis of flyback type current mode control circuit. We made real converter for the gurantee of stable output characteristic and proper design of feedback circuit. The validity of proposed method is verified from test results. The improvement of stability is confirmed by sinusoidal signal injection method with isolated transformer. It is known that phase margin is sufficient and gain crossover frequency $f_c$ is nearly 1/5 of switching frequency $f_s$ from the experimental result with frequency response analyzer.

  • PDF

완전-차동형 바이폴라 전류-제어 전류 증폭기(CCCA) (A fully-differential bipolar current-controlled current amplifier(CCCA))

  • 손창훈;임동빈;차형우
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(2)
    • /
    • pp.289-292
    • /
    • 2001
  • A Novel fully-differential bipolar current-controlled current amplifier(CCCA) for electrically tunable circuit design at current-mode signal processing were designed. The CCCA was consisted of fully-differential subtracter and fully-differential current gain amplifier. The simulation result shows that the CCCA has current input impedance of 0.5 Ω and a good linearity. The CCCA has 3-dB cutoff frequency of 20 MHz for the range over bias current 100$mutextrm{A}$ to 20 ㎃. The power dissipation is 3 mW.

  • PDF

CIM(Current Injection Method)을 이용한 Charge-Pump 방식의 Plasma Backlight용 고압 Inverter (Charge-Pump High Voltage Inverter for Plasma Backlight with Current Injection Method)

  • 장준호;강신호;이준영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.381-383
    • /
    • 2007
  • Charge-pump high voltage inverter for Plasma backlight with CIM(Current Injection Method) is proposed in this paper. Adoption of ERC is a new attempt in high voltage inverter so that it is not only energy recovery but also improvement of discharge stability and system unstability which is interrupted by noise. Using a charge-pump technique enables low voltage switches to be usable, the cost can be reduce. CIM is adopted to achieve high speed energy recovery in proposed circuit. Operations of the proposed circuit are analyzed for each mode. The proposed circuit is verified to be applicable on a 32 inch plasma backlight panel by experimental results.

  • PDF

국제 핵융합실험로용 VS(Vertical Stabilization) 컨버터의 운전모드 및 보호동작 (Operation modes and Protection of VS(Vertical Stabilization) Converter for International Thermonuclear Experimental Reactor)

  • 조현식;조종민;오종석;서재학;차한주
    • 전력전자학회논문지
    • /
    • 제20권2호
    • /
    • pp.130-136
    • /
    • 2015
  • This study describes the structure and operation modes of vertical stabilization (VS) converter for international thermonuclear experimental reactor (ITER) and proposes a protection method. ITER VS converter supplies voltage (${\pm}1000V$)/current (${\pm}22.5kA$) to superconducting magnets for plasma current vertical stabilization. A four-quadrant operation must be achieved without zero-current discontinuous section. The operation mode of the VS converter is separated in 12-pulse mode, 6-pulse mode and circulation current mode according to the magnitude of the load current. Protection measures, such as bypass and discharge, are proposed for abnormal conditions, such as over current, over voltage, short circuit, and voltage sag. VS converter output voltage is controlled to satisfy voltage response time within 20 msec. Bypass operation is completed within 60 msec and discharge operation is performed successfully. The feasibility of the proposed control algorithm and protection measure is verified by assembling a real controller and implementing a power system including the VS converter in RTDS for a hardware-in-loop (HIL) facility.

Local Field Switching 방식의 MRAM 설계 (Design of Local Field Switching MRAM)

  • 이감영;이승연;이현주;이승준;신형순
    • 대한전자공학회논문지SD
    • /
    • 제45권8호
    • /
    • pp.1-10
    • /
    • 2008
  • 본 논문에서는 새로운 스위칭 방식인 LFS (Local Field Switching)을 이용하여 설계한 128비트 MRAM (Magnetoresistive Random Access Memo교)에 대해 기술하였다. LFS 방식은 MTJ (Magnetic Tunnel Junction)를 직접 통과해 흐르는 전류에 의해 형성되는 국소 자기장을 이용하여 MTJ의 극성을 변환시킨다. 이 방식은 MTJ와 전류의 거리가 가깝기 때문에 작은 전류로도 충분히 큰 자기장을 형성하므로 writing current가 적어도 된다. 또한 Digit Line이 없어도 되므로 half select disturbance가 발생하지 않아 기존 MTJ를 이용한 방식에 비해 셀 선택도가 우수하다. 설계한 MRAM은 IT(트랜지스터)-1MTJ의 메모리 셀 구조를 가지며 양방향 write driver와 mid-point reference cell block, current mode sense amplifier를 사용한다. 그리고 MTJ 공정 없이 회로 동작을 확인하기 위해 LFS-MTJ cell을 CMOS emulation cell로 대체하였다. 설계한 회로를 6 metal을 사용하는 $0.18{\mu}m$ CMOS 공정으로 구현하였고 제작된 chip을 custom board 상에서 테스트하여 동작을 확인하였다.

새로운 소프트 스위칭형 벅-부스터 컨버터의 효율개선 (Efficiency Improvement of New Soft Switching Type Buck-Boost Chopper)

  • 고강훈;곽동걸;서기영;권순걸;이현우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 연구회 합동 학술발표회 논문집
    • /
    • pp.44-48
    • /
    • 1998
  • In the buck-boost DC-DC converter which is used at a certain situation such as in factories where loads often change a lot, the switches in the device make big energy loss in operating at Buck-Boost Mode due to hard switching and are affected by lots of stresses which decrease the efficiency rate of the converter. In order to improve this problem, to decrease the loss of snubber and switching, it has been investigated that zero voltage switching mode and zero current switching mode which make the operation of switches with soft switching. For the more sophisticated and advanced device, this paper is presented the Partial Resonant Soft Switching Mode Power Converter which is adapted the power converter having the partial resonant soft switching mode, that makes switches operate when the resonant current or voltage becomes zero by making the resonant circuit partially at turning on and off of the switches with suitable layout of the resonant elements and switch elements in the converter. Also, this paper includes the analysis and simulation of the Partial Resonant type Buck-Boost Chopper.

  • PDF

Lossless Snubber with Minimum Voltage Stress for Continuous Current Mode Tapped-Inductor Boost Converters for High Step-up Applications

  • Kang, Jeong-Il;Han, Sang-Kyoo;Han, Jonghee
    • Journal of Power Electronics
    • /
    • 제14권4호
    • /
    • pp.621-631
    • /
    • 2014
  • To invigorate the tapped-inductor boost (TIB) topology in emerging high step-up applications for off-grid products, a lossless snubber consisting of two capacitors and three diodes is proposed. Since the switch voltage stress is minimized in the proposed circuit, it is allowed to use a device with a lower cost, higher efficiency, and higher availability. Moreover, since the leakage inductance is fully utilized, no effort to minimize it is required. This allows for a highly productive and cost-effective design of the tapped-inductor. The proposed circuit also shows a high step-up ratio and provides relaxation of the switching loss and diode reverse-recovery. In this paper, the operation is analyzed in detail, the steady-state equation is derived, and the design considerations are discussed. Some experimental results are provided to confirm the validity of the proposed circuit.

$CO_2$ 용접에서 전류 펄스 조건이 스패터 발생에 미치는 영향 (The Effect of Current Pulsing Parameters on the Spatter Generation Rate during $CO_2$Shielded Gas Metal Arc Welding)

  • 강덕일;최재호;장영섭;김용석
    • Journal of Welding and Joining
    • /
    • 제16권4호
    • /
    • pp.63-72
    • /
    • 1998
  • In this study, the effects of the current pulsing conditions, on the spatter generation rate during the $CO_2$ gas metal arc welding (GMAW) were investigated. Normally using the inverter type power supply, of which the welding current waveform was regulated to reduce the spatter generation rate, but in this study pulsing was imposed on the welding current. Observation of the metal transfer phenomena during the pulsed current GMAS indicated that the droplet transfer from the electrode via the short circuit transfer and the repelling transfer mode could be minimized by selecting optimum combinations of pulsing parameters, which include base and peak current, base and pak duration. It was also demonstrated in this study that proper combinations of the pulsing parameters led to reduce generation of spatters during GMAW shielded by $CO_2$ gas.

  • PDF

GaN FET를 적용한 인터리브 CRM PFC의 효율특성에 관한 연구 (A Study on the Efficiency Characteristics of the Interleaved CRM PFC using GaN FET)

  • 안태영;장진행;길용만
    • 전력전자학회논문지
    • /
    • 제20권1호
    • /
    • pp.65-71
    • /
    • 2015
  • This paper presents the efficiency analysis of a critical current mode interleaved PFC rectifier, in which each of three different semiconductor switches is employed as the active switch. The Si FET, SiC FET, and GaN FET are consecutively used with the prototype PFC rectifier, and the efficiency of the PFC rectifier with each different semiconductor switch is analyzed. An equivalent circuit model of the PFC rectifier, which incorporates all the internal losses of the PFC rectifier, is developed. The rms values of the current waveforms main circuit components are calculated. By adapting the rms current waveforms to the equivalent model, all the losses are broken down and individually analyzed to assess the conduction loss, switching loss, and magnetic loss in the PFC rectifier. This study revealed that the GaN FET offers the highest overall efficiency with the least loss among the three switching devices. The GaN FET yields 96% efficiency at 90 V input and 97.6% efficiency at 240 V, under full load condition. This paper also confirmed that the efficiency of the three switching devices largely depends on the turn-on resistance and parasitic capacitance of the respective switching devices.

개선된 가딩(Guarding) 회로를 사용한 트랜스콘덕턴스 DRL 회로 (A Transconductance Driven-Right-Leg Circuit with Improved Guarding Circuit)

  • 황인덕
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1644-1650
    • /
    • 2009
  • An improved guarding circuit is applied to a transconductance driven-right-leg circuit to decrease common-mode current at measurement electrodes due to power-line interference. After showing conventional guarding circuit is instable due to gain-peaking when used with a transconductance DRL circuit, the effect of the proposed guarding circuit modified to suppress the gain-peaking by inserting a series resistor between shields and a shield driver was analyzed. It is shown that, besides stability, the proposed guarding circuit provides two other advantages: 1) The gain of the shield driver can be set to be unit nominally. 2) The loop gain of the transconductance DRL loop can be increased due to pole-zero canceling. The proposed circuit was implemented and the advantages were confirmed.