• 제목/요약/키워드: Current test

검색결과 7,152건 처리시간 0.032초

혼합신호 회로를 위한 Specification 기반의 전류 테스트와 최적의 테스트 포인트 선택 (Specification-based Current Test for Mixed-signal Circuits and Optimal Test Point Selection)

  • 장상훈;이재민
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.901-904
    • /
    • 2005
  • Testing of mixed-signal circuit has become a difficult task for test engineers and efficient test solution to these problems are needed. In this paper a new specification-based mixed-signal test method called TSS(Time Slot Specification) using high performance current sensors and a novel test point selection technique without heavy computational overhead are proposed. External output and power nodes are used for test points and accessed by the current sensors in the ATE.

  • PDF

MMC 기반 HVDC 전력변환기의 밸브 성능 시험회로 (Performance Test Circuit for a Valve of MMC Based HVDC Power Converter)

  • 배치환;조광래;김학수;노의철
    • 전력전자학회논문지
    • /
    • 제28권1호
    • /
    • pp.76-81
    • /
    • 2023
  • A new test circuit for an MMC-based valve HVDC power converter is proposed. The proposed scheme satisfies the required clauses from IEC-62501. The valve test current contains second harmonic component and DC offset as well as a fundamental component that is quite similar to the real operating arm current of MMC based HVDC power system. The structure of the proposed test circuit is simple compared to conventional test circuits. Furthermore, the power supply voltage rating of the proposed test circuit is reduced dramatically around 20% of the conventional scheme with the same current rating. The validity of the proposed test circuit is verified through simulation and experimental results.

송변전급(up to class 5) Impulse current test system의 설계 및 특성 (Design & characteristics of impulse current test system for station class(up to class 5))

  • 김석수;최익순;강영식;박병락;박태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1146-1149
    • /
    • 2004
  • A new developed impulse current test system(100kV, 250kJ)is presented, which can carry out all impulse current and performance tests on surge arrester sections with rated voltage up to 12kV according to IEC 60099-4(2001). The maximum achievable peak value is 200kA for the impulse current $4/10{\mu}s$ and 60kA for the $30/80{\mu}s$ and $8/20{\mu}s$. The long duration current impulse is realized from class 1 to class 5. The digital transient recorder(4 channels 60MS/S 10bit) is used for measuring AC voltage, impulse current, reference voltage and leakage current. The complex control, measuring, evaluation and data storage system is controlled by one industrial PC system.

  • PDF

전기화학적 가속 부식 평가법에서 강재의 부식 손상에 미치는 인가전류밀도의 영향 (Effect of Applied Current Density on the Corrosion Damage of Steel with Accelerated Electrochemical Test)

  • 이정형;박일초;박재철;김성종
    • 한국표면공학회지
    • /
    • 제49권5호
    • /
    • pp.423-430
    • /
    • 2016
  • In this study, we investigated the corrosion damage characteristics of steel for offshore wind turbine tower substructure using an accelerated electrochemical test. The galvanostatic corrosion test method was employed with a conventional 3 electrode cell in natural sea water, and the steel specimen was served as a working electrode to induce corrosion in an accelerated manner. Surface and cross-sectional image of the damaged area were obtained by optical microscope and scanning electron microscope. The weight of the specimens was measured to determine the gravimetric change before and after corrosion test. The result revealed that the steel tended to suffer uniform corrosion rather than localized corrosion due to active dissolution reaction under the constant current regime. With increasing galvanostatic current density, the damage depth and surface roughness of surface was increased, showing approximately 25 times difference in damage depth between the lowest current density ($1mA/cm^2$) and the highest current density ($200mA/cm^2$). The gravimetric observation showed that the weight loss was proportionally increased with increment of current density that has 75 times different according by experimental conditions. Consequently, uniform corrosion of the steel specimen was conveniently induced by the electrochemically accelerated corrosion technique, and it was possible to control the extent of the corrosion damage by varying the current density.

대전류표준측정시스템을 위한 STL의 활동 (The activities of Short-circuit Testing Liaison for the high-current standard measurement system)

  • 신영준;김익수;김민규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.437-439
    • /
    • 2001
  • The plan of intercomparison test for high-current system was discussed concretely in the technical committee of STL in 2000. This paper describes the present state of the world, the plan & procedure of intercomparison test and test expenses for high-current system. In conclusion, this mentioned the matters that our country should prepare urgently.

  • PDF

전류변성기의 비오차와 위상오차의 절대 평가 기술 (Absolute Evaluation Method to Obtain Ratio Error and Phase Displacement of Current Transformers)

  • 김윤형;정재갑;한상길;구경완;한상옥
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.153-159
    • /
    • 2008
  • We have developed an absolute evaluation method to obtain the ratio error and phase displacement of a current transformer (CT) without any precise standard CT by measuring four parameters in a CT equivalent circuit. The excitation admittance in the CT equivalent circuit can be obtained by employing standard resistors with negligible reactive component. The secondary leakage impedance in the CT equivalent circuit can be measured using a universal impedance bridge. The method was applied to CTs under test with the wide current ratios in the range of 5 A / 5 A - 5,000 A / 5 A and 5 A / 1 A - 5,000 A / 1 A. The ratio error and phase displacement of the CT under test obtained in this study are consistent with those measured at the national institute in Canada using the same CT under test within an expanded uncertainty (k = 2) in the overall current ratios.

$2{\times}25 kV$급전 방식에서의 공동 접지망 적용에 따른 귀선 전류의 영향 (Effects of the Common Earth Network on the Traction Return Current in $2{\times}25 kV$ Power Supply System)

  • 김용규;류창근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권9호
    • /
    • pp.509-514
    • /
    • 2002
  • The aim of this research is to find out how the common earth network affects the level of the traction return current in the $2{\times}25 kV$ Power Supply System. The traction return current plays a significant role in the operation of the facilities near the rails. It is shown that the common earth network in the $2{\times}25 kV$ power supply system not only minimizes the level of the traction return current, but also increases the safety of the working crew on the railways. In order to determine the relationship between common earth network and the traction return current, we investigated the earth system of the Gyongbu High Speed Line that is constructed following the SNCF regulations. We carried out the field test in the Osong station. The results of the test show that the common earth network minimizes the effect of the traction return current. We also find that the simulated results are very similar to the test results. We concluded that the results of the test can be applied for the rest of the Gyongbu High Speed Line under construction.

배전용 피뢰기의 가속열화시험 (Accelerating aging test of distribution lightning arresters)

  • 김주용;송일근;김찬영;이병성;문재덕
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.596-598
    • /
    • 2000
  • This paper presents a new accelerating aging test facility for distribution lightning arresters. Aging parameters of lightning arrester are moisture ingress, electrical stress and surge absorption and so on. In this system, we applied 13.2kV to 6 samples and controled temperature and humidity of chamber and measured leakage currents of the all samples. Also we developed accelerating aging cycle which consists of -35$^{\circ}C$∼90$^{\circ}C$ temperature and 40%∼90% humidity. Through the aging test we found out the leakage current of aged sample increases rapidly according to the temperature rising. Hereafter we can determine the replacement guide of leakage current for field operating arresters and condition assessment of aged samples through this aging test.

  • PDF

교류 스위치-퓨우즈 조합기기의 차단특성에 관한 고찰 (The study of short-circuit breaking characteristics of high-voltage alternating current switch-fuse combinations)

  • 노창일;나대열;김선구;정흥수;김원만;이동준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.836-838
    • /
    • 2004
  • Alternating current switch-fuse combinations shall be designed so as to protect for load circuit of distribution line. this switch system shall be test on making and breaking at short-circuit current. the test dutys were performed to prove correct coordination between the switch and fuses in applied test conditions This paper describes characteristics and test method for prove to performance of alternating current switch-fuse combinations.

  • PDF

피뢰기용 단로기의 특성 및 성능 평가 (Properties & Performance Evaluation of Disconnector for Surge Arrester)

  • 김석수;최익순;정낙헌;박태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.546-547
    • /
    • 2005
  • This study aims to evaluate the properties and the performance of the newly designed disconnector for surge arrester. This disconnector was verified with the performance in long-duration current impulse test and high current impulse test. And time-current characteristic test was done at 20A, 200A and 800A(3points) for simulating the internal fault condition of the arrester. The results of this test was very good. Consequently, the newly designed disconnector was, evaluated that it is possible to be used for surge arrester in distribution line system.

  • PDF