• Title/Summary/Keyword: Current test

Search Result 7,143, Processing Time 0.037 seconds

Current Range Extension of Current Transformers by Using Absolute Evaluation Technique and Two Different Current Transformers (전류변성기 절대 평가 기술과 전류변성기 두 대를 이용한 전류 범위 확장)

  • Kim, Yoon-Hyoung;Han, Sang-Gil;Jung, Jae-Kap;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.69-71
    • /
    • 2008
  • We have developed a current range extension method to obtain the ratio error and phase displacement of a current transformer (CT) by using absolute evaluation method and two different CTs. The method was applied to CTs under test with the current ratios of the range of 5,000 A / 1 A - 20,000 A / 1 A. The ratio error and phase displacement of the CT under test obtained in this study are consistent with those measured at the national institute in Germany using the same CT under test within an expanded uncertainty (k = 2) in the overall current ratios.

  • PDF

Characteristics of Lightning Impulse Current of Zno Block for Transmission Line Arrester with External Gap (송전선로에 사용되는 갭형 피뢰기 소자의 뇌임펄스 전류특성)

  • Cho, Han-Goo;Yoo, Dae-Hoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.04b
    • /
    • pp.61-62
    • /
    • 2009
  • This paper describes the characteristics of lightning impulse current of ZnO block for transmission line arrester with external gap. The ageing parameters of lightning arresters ate impulse current, moisture ingress, temperature ageing and so on. Especially it is important to estimate the change of electrical characteristics by impulse current. Total energy applied to the ZnO arrester each time is $4/10{\mu}s$, 30kA and $2/20{\mu}s$, 10kA impulse current. Before and After the test, the residual voltage variation of varistors passed was below 5%. According to the test, it is thought that the ZnO arrester shows good stability with impulse current test.

  • PDF

Practical Fault Coverage of Supply Current Testing for Open Fault in TTL Combinational Circuits

  • Mushiaki, Yukiko;Hashzume, Masaki;Yotsuyanagi, Hiroyuki;Tamesada, Takeomi
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.383-386
    • /
    • 2000
  • There are some variations in quiescent supply current or TTL SSIs. Thus, some variations in quiescent supply current of logic circuits made of TTL SSIs will be generated. The variations make it difficult to apply supply current test methods to tests of TTL circuits. In this paper, in order to examine the applicability to R circuits, fault coverages of a supply current test method for open faults in some ISCAS-85 benchmark circuits are evaluated, Which are made of TTL LS-type SSIs. The experimental results shows that if SSIs are used for implementation having the variation of quiescent supply current within 1%, supply current test methods are applicable for the tests.

  • PDF

Characteristics of Lightning Impulse Current of ZnO Block for Transmission Line Arrester with External Gap (송전선로에 사용되는 갭형 피뢰기 소자의 뇌임펄스 전류특성)

  • Cho, Han-Goo;Yoo, Dae-Hoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.458-459
    • /
    • 2007
  • This paper describes the characteristics of lightning impulse current of ZnO block for transmission line arrester with external gap. The ageing parameters of lightning arresters are impulse current, moisture ingress, temperature ageing and so on. Especially it is important to estimate the change of electrical characteristics by impulse current. Total energy applied to the ZnO arrester each time is $4/10{\mu}s$, 30kA and $2/20{\mu}s$, 10kA impulse current. Before and After the test, the residual voltage variation of varistors passed was below 5%. According to the test, it is thought that the ZnO arrester shows good stability with impulse current test.

  • PDF

Development Trends of Tidal Current Energy and Its Test Bed (조류에너지의 이용기술)

  • Yang, Changjo;Hoang, T.G.
    • Vacuum Magazine
    • /
    • v.3 no.2
    • /
    • pp.11-16
    • /
    • 2016
  • Tidal current energy is the most interesting renewable resources that have been less harnessed. Korea has globally outstanding tidal current energy resources and it is highly needed to develop a tidal current energy conversion system. It is reported that the total amount of available tidal current energy is approximately 6GW in Korea. A good tidal site candidate is required a large amount of fast moving water, bathymetry and seabed properties, no conflicts with other users and is close to a load and grid interconnection. In this review, we summarized the results of R&D projects regarding tidal current resources, utilization projects and demonstration test bed.

A Study on the Measurement Technique of the Grounding Mesh Resistance by Field Measurements (현장실측에 의한 메시(Mesh)접지저항 출정기법 연구)

  • 한기붕;김삼수;정세중;이상익
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.426-429
    • /
    • 1999
  • In this paper, we have provided the measurement technique of the grounding mesh resistance by field measurements. The standard of measurement is specified in the IEEE Std 81.2-1991 and JEAC 5001-1988, which is the the fall-of-potential method by test-current injection, but this method is difficult to apply at field, where is small around a electric power substation of domestic. For the convenient measurement method, space of assistant probe and quantity of test-current injection are changed step for step. As the result, ' the proposed measurement technique of grounding mesh resistance is that the space of current and potential probes must be fixed at 150rn from a grounding mesh, the test-current injection has to keep 5A or more.

  • PDF

A Study on the Construction of Test circuit and Unification of Experiment Method for High Voltage Gas-insulated Load Switch using High Power Testing System (특고압 가스 절연 부하 개폐기의 통합형 대전력 시험 방법 및 회로 구성에 관한 연구)

  • Jung, Heung-Soo;Kim, Min-Young;Kim, Juen-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.36-46
    • /
    • 2008
  • This paper is to study on the Construction of Test circuit and Unification of Experiment Method for high voltage gas-insulated load switch using high power testing system The high power testing system is a equipment to verify electrical and mechanical performance on electrical product. The system consist of short-circuit generator, back-up breaker, making switch, impedance, high voltage transformer, low voltage transformer, measuring and protection system, etc. Using this system, we can test related to high power, for example, short-time current test, active load Current test, magnetizing Current test, capacitive current test, closed loop current test, etc. Standards of high voltage gas-insulated load switch that is in use domestic distribution line are ES 5925-0002, IEC 60265-1, IEC 62271-1 and IEEE C 37.74, etc. In this paper, we standardized on the test procedure, organization of test circuit and analysis of measured data prescribed many difference standards, and applied this test method to 600[MVA] high power testing system. So that we can test the load switch satisfied standards.

A Study on the Design of DC Parameter Test System (DC 파라메터 검사 시스템 설계에 관한 연구)

  • 신한중;김준식
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.4 no.2
    • /
    • pp.61-69
    • /
    • 2003
  • In this paper, we developed the U parameter test system which inspects the property of DC parameter for semiconductor products. The developed system is interfaced by IBM-PC. It is consisted of CPLD part, ADC (Analogue to Digital Converter), DAC (Digital to Analogue Converter), voltage/current source, variable resistor and measurement part. In the proposed system, we have designed the constant voltage source and the constant current source in a part. The CPLD part is designed by VHBL, which it generates the control and converts the serial data to parallel data. The proposed system has two test channels and it operates VFCS mode and CFVS mode. The range of test voltage is from 0[V] to 100[V], and the range of test current is from 0[mA] to 100[mA)]. The diode is tested. The test results have a good performance.

  • PDF

Aircraft Lightning Test Methods (항공기 낙뢰시험)

  • Choi, I.S.;Kim, S.S.;Han, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1790-1792
    • /
    • 2004
  • This paper deals with the lightning test methods on aircraft. It shows lightning current and voltage test waveforms referred to SAE ARP 5412. According to this standard, to test lightning effects, mixes appropriately 5 waves for current and 4 waves for voltage depend on structure and comparison information.

  • PDF

Performance Test Circuit and Control Method for Submodule of MMC-HVDC System (MMC-HVDC 시스템용 서브모듈 성능시험회로와 제어기법)

  • Jo, Kwang-Rae;Seo, Byuong-Jun;Park, Kwon-Sik;Kim, Hak-Soo;Heo, Jin-Yong;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.6
    • /
    • pp.452-458
    • /
    • 2019
  • This study proposes a new test circuit and control method for the submodules of modular multilevel converter (MMC)-based HVDC systems. The test current of conventional submodule test circuits cannot provide the DC offset components or may have some distortion in the linearized current with the DC offset. The proposed scheme can provide not only the DC component but also linearized current without distortion. Therefore, the submodule test current waveform is relatively similar to that of a real submodule consisting of an MMC-based HVDC system. The validity of the proposed circuit and control method is verified through a simulation and experiment.