• Title/Summary/Keyword: Current source

Search Result 3,994, Processing Time 0.038 seconds

A Study on characteristics of Current-Fed Type Inverter driven by Voltage Source (전압원 구동시의 전류형 인버어터의 특성연구)

  • Lee, Dal-Hae;Kim, Dong-Hee;Lee, Bong-Seop;Yoo, Dong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.587-590
    • /
    • 1991
  • It is general to make the circuit analysis of current-fed type inverter driven by current source with rippleless input under the assumption of infinite induction Ld in direct current reactor(DCL). This paper focusing on the fact that Ld has bounded value in real circuit, examines operating characteristics by analysis of static state characteristics of current type inverter driven by voltage source and compares it with the operating characteristics of the circuit driven by current source.

  • PDF

Vth Compensation Current Source with Poly-Si TFT for System-On-Panel (System-On-Panel을 위한 Poly-Si TFT Vth보상 전류원)

  • Hong, Moon-Pyo;Jeong, Ju-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.10 s.352
    • /
    • pp.61-67
    • /
    • 2006
  • We developed a constant current source which is insensitive to threshold voltage variation caused by irregular grain boundary distribution in polycrystalline silicon. The proposed current source has superior saturation characteristics over wide range of input voltages as well as small current error compared to the previously reported Vth compensated sources. We measured the circuit performance and error in current due to parameter variation by using HSPICE.

Parallel Operation Systems of Z-Source Inverters for Fuel Cell Systems (연료 전지 시스템을 위한 Z-소스 인버터고 구성된 병렬 운전 시스템)

  • Moon Hyun-Wook;Jeong Eun-Jin;Kim Yoon-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.443-449
    • /
    • 2005
  • In this paper, parallel operation systems with Z-source Inverters for the fuel cell systems are discussed. The carrier phase shifted SPWM(Sinusoidal Pulse Width Modulation) has an advantage in reducing harmonics of output current. However when this technique applies in parallel operation of Z-source inverters, it additionally produces circulating currents. The circulating current is analyzed and a method to prevent the circulating current is applied to the parallel operation systems of Z-source inverters. To maintain high performance with reduced circulating current in inverter output and low harmonic components in load current, circulating current reactors are used. The proposed approach is verified through simulation and experiment.

Current Mode Integrated Control Technique for Z-Source Inverter Fed Induction Motor Drives

  • Thangaprakash, Sengodan;Krishnan, Ammasai
    • Journal of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.285-292
    • /
    • 2010
  • This paper presents a current mode integrated control technique (CM-ICT) using a modified voltage space vector modulation (MSVM) for Z-source inverter (ZSI) fed induction motor drives. MSVM provides a better DC voltage boost in the dc-link, a wide range of AC output voltage controllability and a better line harmonic profile. In a voltage mode ICT (VM-ICT), the outer voltage feedback loop alone is designed and it enforces the desired line voltage to the motor drive. An integrated control technique (ICT), with an inner current feedback loop is proposed in this paper for the purpose of line current limiting and soft operation of the drive. The current command generated by the PI controller and limiter in the outer voltage feedback loop, is compared with the actual line current, and the error is processed through the PI controller and a limiter. This limiter ensures that, the voltage control signal to the Z-source inverter is constrained to a safe level. The rise and fall of the control signal voltage are made to be gradual, so as to protect the induction motor drive and the Z-source inverter from transients. The single stage controller arrangement of the proposed CM-ICT offers easier compensation. Analysis, Matlab/Simulink simulations, and experimental results have been presented to validate the proposed technique.

Photovoltaic System using the Stepdown Chopper and Current Source Inverter (강압쵸퍼와 전류형 인버터를 이용한 태양광발전 시스템)

  • 성낙규;이승환;김성남;이훈구;김용주;한경희
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.370-373
    • /
    • 1997
  • In this paper, we compose of the stepdown chopper and the current source inverter. Because dc side current of the current source inverter pulse with twice frequency of utility, we control that modulation factor of chopper is pulsed twice frequency. Therefore if voltage across the dc reactor equal to zero, it tis decreased. And we control modulation factor of the chopper to operate at maximum power point around of solar cell.

  • PDF

Single Sensor Current Control for Three-Phase Voltage-Source PWM Converters Using a Predictive State Observer (예측 상태 관측기를 이용한 3상 전압 원 PWM 컨버터의 단일 센서 전류 제어)

  • 이우철;현동석;이택기
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.489-492
    • /
    • 1999
  • This paper proposes a control method for three-phase voltage-source PWM converters using only a single current sensor in the DC link. A predictive current controller for the voltage-source PWM converter is used so that all phase currents can be reconstructed in a switching period although one or two of active vectors are applied only for a short time. Compensation of the 2 step delays is also included. In this paper single sensor current control using predictive state observer will be discussed, and investigated experimentally.

  • PDF

Gate Leakage Current Characteristics of GaAs MESFETs with Different Temperature (GaAs MESFET의 온도변화에 대한 게이트누설전류 특성)

  • Won, Chang-Sub;Hong, Jea-Il
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.24-27
    • /
    • 2003
  • In this paper, We make experiment on two methode for GaAs MESFET with temperature variation. One method, we mesure gate leakage current at open source electrode. another we mesure gate leakage current at short source electrode. The difference of two current has been tested and provide that the existence of another source to Schottky barrier height against the image force lowering effect.

  • PDF

AKARI-FIS POINT SOURCE CATALOGUE: CURRENT STATUS AND FUTURE PLAN

  • Yamamura, Issei;Makiuti, Sin'itirou;Ikeda, Norio;Koga, Tatsuya;Yoshino, Akira;Yamauchi, Chisato
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.4
    • /
    • pp.105-109
    • /
    • 2012
  • The current status of the AKARI-FIS Point Source Catalogue is reported. The first version of the Bright Source Catalogue has been in public since March 2010 and used extensively in the various fields in astronomy. The second version of the Bright Source Catalogue and the first version of the Faint Source Catalogue are currently under development. The revised Bright Source Catalogue is expected to have improved completeness, reliability, and accuracy compared to the current version. The Faint Source Catalogue will have a scan-density dependent detection limit and will enable much deeper exploration of the sky especially in the high-ecliptic latitude regions. Both catalogues will be available in a year time scale.

Integrative Control of Series Active Power Filters for Source Voltage Unbalance Compensation and Power Factor Correction (전원 불평형과 역률을 보상하는 직렬형 능동전력필터의 통합적 제어)

  • Jang, Jeong-Ik;Seok, Jul-Ki;Lee, Dong-Choon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.5
    • /
    • pp.258-264
    • /
    • 2006
  • This paper presents an integrative control scheme for series-type active power filters combined with shunt passive filters not only to compensate for the source voltage unbalance and current harmonics but also to correct the power factor. To reduce the power capacity of the active filters, passive filters are connected in parallel. Diode rectifiers are replaced by the PWM converters in order to feed the real power back to the source. Power factor control is performed by changing the phase of the load voltage so that the phase of the source current coincides with that of the source voltage. The resultant voltage reference is the addition of the voltage component compensating for the source voltage unbalance and harmonic currents and the voltage component correcting the power factor. The validity of the proposed algorithm has been verified by experimental results.

Comparison of Efficiency for Voltage Source and Current Source Based Converters in 5MW PMSG Wind Turbine Systems (전압형 및 전류형 컨버터를 적용한 5MW PMSG 풍력발전시스템의 효율 비교)

  • Kang, Tahyun;Kang, Taewon;Chae, Beomseok;Lee, Kihyun;Suh, Yongsug
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.5
    • /
    • pp.410-420
    • /
    • 2015
  • This paper provides a comparison of power converter loss and thermal description for voltage source and current source type 5 MW-class medium-voltage topologies of wind turbines. Neutral-point clamped three-level converter is adopted for a voltage source type topology, whereas a two-level converter is employed for current source type topology, considering the popularity in the industry. To match the required voltage level of 4160 V with the same switching device of IGCT as in the voltage source converter, two active switches are connected in series for the case of current source converter. Transient thermal modeling of a four-layer Foster network for heat transfer is done to better estimate the transient junction and case temperature of power semiconductors during various operating conditions in wind turbines. The loss analysis is confirmed through PLECS simulations. Comparison result shows that the VSC-based wind turbine system has higher efficiency than the CSC under the rated operating conditions.