• 제목/요약/키워드: Current pulse

검색결과 1,872건 처리시간 0.026초

소프트웨어 PLL 기반 소형 고속 BLDC의 속도 제어 (Software PLL Based Speed Control of High Speed Miniature BLDC)

  • 박태흡;석승훈;이동희;안진우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.132-135
    • /
    • 2008
  • This paper presents a PLL(Phase Lock Loop) control method for speed control of high speed miniature BLDCM(Brushless DC Motor) using hall sensor. The Proposed PLL based speed control method uses a only phase shift between reference pulse signal according to speed reference and actual pulse signal from hall sensor. It doesn't use any speed calculation, and calculates a direct current reference from phase shift. The current reference is changed to reduce the phase shift between reference and actual pulse. So the actual speed can keep the reference speed. The proposed control scheme is very simple but effective speed control is possible.

  • PDF

Pulse MAG 용접용 전원의 출력파형 제어 (Welding Current Waveform Control of Power Source for Pulse MAG)

  • 구헌회;변영복;조상명;이현우;심우용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2118-2120
    • /
    • 1998
  • Recently the automatization and the robotization of the arc welding industry is promoted and also the improvement of the welding quality and the work efficiency is required strongly. In this paper, special welding current waveform control algorithm is developed for less spatter and improvement of welding performance in the high speed and low arc voltage range. And the output control and the short circuit waveform control to the varition of the welding is studied by appling the algorithm to the power source for pulse arc welding.

  • PDF

Feed-Forward Approach in Stator-Flux-Oriented Direct Torque Control of Induction Motor with Space Vector Pulse-Width Modulation

  • Kizilkaya, Muhterem Ozgur;Gulez, Kayhan
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.994-1003
    • /
    • 2016
  • Two major obstacles in the utilization of electrical vehicles are their price and range. The collaboration of direct torque control (DTC) with induction motor (IM) is preferred for its low cost, easy implementation, and parameter independency. However, in terms of edges, the method has drawbacks, such as variable switching frequency and undesired current harmonic distortion. These drawbacks result in acoustic noise, reduced efficiency, and electromagnetic interference. A feed-forward approach for stator-flux-oriented DTC with space vector pulse-width modulation is presented in in this paper. The outcome of the proposed method is low current harmonic distortion with fixed switching frequency while preserving the torque performance and simple application feature of basic DTC. The method is applicable to existing and forthcoming IM drive systems via software adaptation. The validity of the proposed method is confirmed by simulation and experimental results.

대전류 펄스 성형을 위한 300kJ급 커패시터뱅크 모듈의 특성 평가 (Evaluation of 300kJ Capacitor Bank Module for High Current Pulse Shaping)

  • 황동원;이홍식;진윤식;조주현;김종수;임근희;박원주;김진성;정재원;추중호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2086-2088
    • /
    • 2000
  • Key elements of in the development Electro-Thermal-Chemical propulsion (ETC) are high current pulse shaping, switching and storage bank device with high energy density 300kJ pulse power capacitor bank module for ETC application is designed and fabricated. The tested result are described.

  • PDF

Development of High Flux Metal Ion Plasma Source for the Ion Implantation and Deposition

  • Kim, Do-Yun;Lee, Eui-Wan
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제7권2호
    • /
    • pp.45-56
    • /
    • 2003
  • A high flux metal plasma pulse ion source, which can simultaneously perform ion implantation and deposition, was developed and tested to evaluate its performance using the prototype. Flux of ion source was measured to be 5 A and bi-polar pulse power supply with a peak voltage of 250 V, repetition of 20 Hz and width of 100 ${\mu}\textrm{s}$ has an output current of 2 kA and average power of 2 kW. Trigger power supply is a high voltage pulse generator producing a peak voltage of 12 kV, peak current of 50 A and repetition rate of 20 Hz. The acceleration column for providing target energy up to ion implantation is carefully designed and compatible with UHV (ultra high vacuum) application. Prototype systems including various ion sources are fabricated for the performance test in the vacuum and evaluated to be more competitive than the existing equipments through repeated deposition experiments.

  • PDF

SRM의 센서리스제어를 위한 상인덕턴스 추론기법 (Phase Inductance Reasoning Strategy for Sensorless Control of SRM)

  • 김태형;김봉철;안진우;김흥근
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.523-525
    • /
    • 2004
  • This paper describes a new method of detecting rotor position in switched reluctance motor(SRM). Some strategies of position sensorless control methods for the motor include the measurement of phase current and applied pulse voltage in an unexcited phase. The principle of the estimation of a rotor position is based on the detection of inductance by pulse currents. Suggested method is verified by some experimental tests.

  • PDF

A Seamless Control Method for Supercapacitor to Compensate Pulse Load Transients in DC Microgrid

  • Dam, Duy-Hung;Lee, Hong-Hee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.198-199
    • /
    • 2017
  • This paper proposed a new control method for supercapacitor (SC) to compensate the pulse load transient and enhance the power quality of dc microgrid. By coordinating the operation frequency, the supercapacitor is controlled to handle the surge current component while the low-frequency current component is dealt with by remaining sources in the system. Based on the state of charge and dc bus voltage level, the SC unit operation mode is automatically decided. Meanwhile, the dc bus voltage level indicates the power demand of the whole system; by regulating the dc bus voltage, the mismatch of power demand is covered by SC unit. The effectiveness of proposed method is verified by experiment prototype formed by two distributed generation and one supercapacitor unit.

  • PDF

2종류의 양말착의행동이 인체생리반응에 미치는 효과 (Effects of Two Kifferent Kinds of Socks on Physiologrical Responses)

  • 김희은;권오경
    • 한국의류학회지
    • /
    • 제23권2호
    • /
    • pp.242-249
    • /
    • 1999
  • The purpose of this study was to investigate two different kinds of socks on physiological responses at an ambient temperature of 35$\pm$1$^{\circ}C$ and relative humidity of 50$\pm$5% Five healthy women wearing normal socks or toes socks participated as the subjects. Rectal temperature skin temperatures sweat rate blood pressure pulse rate and questionnaire wee measured. Rectal temperature skin temperature sweat rate blood pressure pulse rate and questionnaire were measured. Rectal temperature and mean skin temperature were lower after exercise at wearing toes socks . Sweat rate was higher at wearing normal socks and blood pressure and pulse rate were tend to higher at wearing toes socks. Thermal comfort temperature sensation and humidity sensation were better wearing toes socks. Thermal comfort temperature sensation and humidity sensation were better wearing toes socks than wearing normal socks but wearing comfort was better at wearing normal socks. These results will be discussed form the viewpoint of thermoregulation AVA(Arterio venous Anastomosis) and count current heat exchange.

  • PDF

펄스 파형전해에 의한 3가 크롬도금 (Trivalent chromiun plating by using pulse electrolysis)

  • 추현식;김연신;이홍로
    • 한국표면공학회지
    • /
    • 제30권2호
    • /
    • pp.104-110
    • /
    • 1997
  • Conventional hexavlent chromium electroplating baths deposit the matal at low cathode efficiency and have poor covering and throwing power. The processs also generate hazardous wastes. To overcome many of the disadvantages of hexavalent chromium plating the use of trivalent chromium has advocted. After Yoshida, who first studied trivalent chromium plating, using ammonium sulfate and urea, there are numerous report describing the trivalent chromium electropating process using complexing agents. This study investigaten trivalent chromium plating electrolyte solutious containing formate as a complexing agent and ammouim chloride for conducting agent. The effects of composition and operating conditions on deposits and current efficiencies were investigated in trivalent chromium plating baths by analyzing the relationship pulse conditions and surface morphology The surface morphology of the deposits was observed by SEM. pulse electrolysis has been effective on obtaining a smooth with high current efficiency comparing with D.C. electrolysis in trivalent chromium solution.

  • PDF

An Efficiency-Optimized Modulation Strategy for Dual-Active-Bridge DC-DC Converters Using Dual-Pulse-Width-Modulation in the Low Power Region

  • Byen, Byeng-Joo;Ban, Chung-Hwan;Lim, Young-Bae;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • 제17권6호
    • /
    • pp.1413-1421
    • /
    • 2017
  • In order to control the output voltage in a dual active bridge converter, this paper establishes a theoretical inductor current equation for a dual-pulse-width-modulation scheme that ensures low switching loss. It also proposes a modulation strategy that minimizes conduction loss. When compared to the conventional single-pulse-width-modulation strategy, the proposed approach can reduce the inductor current RMS and improve efficiency in the low power region, as verified through simulation and experimental results.