• 제목/요약/키워드: Current limiting breaking

검색결과 17건 처리시간 0.027초

Comparison of HTS conductors for a DC resistive type fault current limiting module

  • So, Jooyeong;Lee, Seyeon;Choi, Kyeongdal;Lee, Ji-kwang;Kim, Woo-Seok
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제21권4호
    • /
    • pp.39-43
    • /
    • 2019
  • The breaking of a circuit in DC grid could pose a challenge because of the absence of zero-crossing instant for both current and voltage when a fault occurs. An additional fault current limiting function will be very helpful for reducing the burden of the DC circuit breaker by limiting the fault current to a reasonable value. In this paper, we studied the overcurrent characteristics of several HTS conductors so that we could use the selected conductors for the basic design work of a resistive type fault current limiting module as a part of the circuit breaking system. According to the short-circuit test results, we suggested and compared two different basic design parameters of the HTS fault current limiting module, which will be connected in series to the DC circuit breaker.

중소형 회로 차단기에 적용 가능한 한류 메커니즘의 개발 (A Study on the impact on the quality of hemming the number of hemming process)

  • 이제덕;박종식;임재국;박동희;박민호;최계광;김세환;윤재웅;이춘규
    • Design & Manufacturing
    • /
    • 제10권1호
    • /
    • pp.41-45
    • /
    • 2016
  • Electrical equipment in factories, buildings, etc. with the development of the industry has become a large capacity. By the development, electric load also become diversified and there is also highly functional requirements being electrical equipment. Particularly in the small and medium-sized circuit breakers, tend to preferentially consider the economy stands out and improvements in safety, ease of mounting and connection through the modularity of the basic dimensions compact and cost to block expansion of the scope of the development of capacity, etc. The product having a competitive has been strongly required. In order to implement the circuit breakers of breaking capacity and compact at the same time taking into account the economic development of this technology applied to the current-limiting mechanism is essential budget or the current limiting mechanism is currently available mechanisms applicable to small and medium-sized frame (frame) can not do it. In this paper, at the same time satisfying the economic efficiency, by minimizing the load force of the moving contactor (moving contactor) to be applied to small and medium frame other hand to secure the economical efficiency without using high speed contact parting acceleration of the moving contactor conventional current-limiting mechanism, and to develop a current-limiting mechanism that can be satisfied with the same or higher performance to meet the needs of the market.

전력계통에 초전도한류기 적용시 차단용량 확보를 위한 초전도한류기 적용방안 연구 (Analysis on the Application Capacity of the Superconducting Fault Current Limiter considering Reclosing and Fault Current)

  • 김진석;임성훈;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.592-593
    • /
    • 2015
  • Recently, the fault current has increased to exceed the rated breaking capacity of protective device due to the growth of the power demand on the power system where is changed into the loop-, mesh-, network grid. To limit fault current, the superconducting fault current limiter (SFCL) is announced with various methods. In many researches, the current limiting effect with the SFCL has been analyzed considering the rated breaking capacity of the CB with one fault condition. However, the power system has various short circuit and operation conditions. In order to select the capacity of the SFCL with reclosing operation and burden of the fault current on the protective device, the characteristics of the power system were investigated. Through the analysis, the evaluation method of the current rate was improved.

  • PDF

전력용 백업퓨우즈 차단특성 모델링 (Empirical Modeling on the Breaking Characteristics of Power Current Limited Fuse)

  • 이세현;이병성;한상옥
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권9호
    • /
    • pp.391-396
    • /
    • 2005
  • In this paper the modeling of interrupting characteristics of a high voltage current limiting fuse to be used in a power distribution system is introduced. In order to reduce the level of energy which can be absorbed by equipment during fault current flow, a high voltage current limiting fuse can generate a high voltage at the fuse terminals. Consequently it is necessary to model and analyze precisely the voltage and current variation during a CL fuse action. The characteristics of CL fuse operation modeled by electrical components have been performed with less than 6 [$\%$] errors. So the fuse designer or manufacturer can estimate the characteristics of CL fuse operation by using this modeling. The Electro Magnetic Transient Program (EMTP) is used to develop the modeling.

Interruption analysis of the SFCL-combined DC circuit breaker system using current-limiting technology

  • Kim, Jun-Beom;Jeong, In-Sung;Choi, Hye-Won;Choi, Hyo-Sang
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권4호
    • /
    • pp.30-34
    • /
    • 2016
  • In this study, a SFCL-combined DC circuit breaker system was proposed by applying the current-limiting technology for DC circuit breaking. The SFCL-combined circuit breaker system consists of a mechanical DC circuit breaker combined with superconductors. To ensure the reliable structure and operation of the SFCL-combined circuit breaker system, a simulation grid was designed using the EMTDC/PSCAD program, and simulation was conducted. The results showed that the SFCL-combined DC circuit breaker system with superconductors limited the maximum fault current by 37%. In addition, the burden on the DC circuit breaker was decreased by 87%.

DC Superconducting fault current limiter characteristic test with a DC circuit breaker

  • So, Jooyeong;Choi, Kyeongdal;Lee, Ji-kwang;Kim, Woo-Seok
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권2호
    • /
    • pp.19-23
    • /
    • 2021
  • We have studied the breaking system that combines a resistive superconducting fault current limiter (SFCL) and a DC circuit breaker for DC fault current. To verify the design of the 15 kV DC SFCL, which was driven from the previous work, a 500 V DC system was built and a scale-down SFCL were manufactured. The manufactured SFCL module was designed as a bifilar coil which is a structure that minimizes inductive reactance. The manufactured SFCL module has been experiment to verify characteristics of the current-limiting performance in the DC 500 V system. Also, the manufactured FCL module was combined with the DC circuit breaker to be experimented to analyze the breaking performance. As a result of the experiment, when SFCL was combined to the DC circuit breaker, the energy dissipation received by the DC circuit breaker was reduced by up to 84% compared to when the DC circuit breaker operates alone. We are preparing methods and experiments for the optimal method for much higher performance as a future work.

과전류 차단과 보호협조 성능이 향상된 한류형 COS 퓨즈링크 개발 (Development of Current Limiting COS Fuse Link with Improved Overcurrent and Protection Coordination performance)

  • 김윤현;김영주
    • 한국산학기술학회논문지
    • /
    • 제21권3호
    • /
    • pp.129-136
    • /
    • 2020
  • 컷아웃스위치(COS: Cut Out Switch 이하 COS)는 전력계통에서 수용가로 전력을 송배전하기 위해 사용되는 변압기의 입력단에 설치되어 사고전류로부터 변압기를 보호하기 위해 설치되는 보호장치이다. COS는 크게 퓨즈링크와 COS몸체 및 접속부로 구성되어 사고전류시 퓨즈링크의 엘리먼트가 용단되어 사고전류를 차단하는 역할을 한다. COS 퓨즈링크가 용단되어 발생하는 강력한 아크가 화염과 소음을 유발시켜 주변지역 거주자에게 불쾌감 및 공포감을 주며, 아크화염으로 인하여 주변기기의 2차 피해를 유발시킬 수 있다. 본 논문에서는 COS 동작 시 발생되는 아크와 소음 및 보호협조의 문제점을 해결하기 위해 폭발형이 아닌 한류형 COS 퓨즈를 개발하였다. 또한 과전류 차단 기능이 없는 한류형 퓨즈의 단점을 개선하기 위해 퓨즈 엘리멘트, 스트라이커와 COS 퓨즈금구 개발을 통하여 과전류 차단성능의 신뢰성을 향상시켰다. COS의 동작 특성 향상은 퓨즈 엘리멘트의 최적 형상 도출, 스트라이커의 원활한 동작을 위한 동작선의 재질과 두께 및 저항 산정, 그리고 스트라이커와 연계된 하부금구류의 구조 개선을 통하여 수행하였다. 본 연구에서 개발한 COS 퓨즈링크는 공인기관의 시험을 통하여 차단성능과 보호협조 성능을 검증하였다. 시험은 본 연구의 한류형 COS와 기존의 폭발형 비한류형 COS의 비교 시험으로 수행하였다.

RF Sputtering을 이용한 전류 민감성 차단 디바이스에 관한 연구 (The Study on a sensitive current limiting breaking device using RF Sputtering)

  • 이세현;정광희;박두기;김용락;이종철;구경완;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1088-1092
    • /
    • 1995
  • In this paper, we evaluated the sputter-deposited Cr/Cu thin film fuses on $Al_2O_3$ substrates by the adhesive, breaking and repetitive over-current test as a function of temperature on them. Each Cr and Cu was deposited $1700{\pm}300{\AA},\;3700{\pm}300{\AA}$ using RF sputtering unit. The electroplated Cu of $25{\mu}m$ thickness was added in order to make sensitive thin film fuse of the normal current 15[A]. The adhesive strength and the number of repetition were Increasing and then decreasing with the temperature. The maximum adhesive strength of over $9kgf/9mm^2$ was obtained at $400^{\circ}C$. In the breaking test, the post-arc time characteristic was better than any other factor.

  • PDF

전력 계통 신뢰도 개선을 위한 대표적인 한류기 유형 및 적용 효과 분석 (Review of Typical Fault Current Limiter Types and Application Effect to Improve Power System Reliability)

  • 고윤석;이우철
    • 한국전자통신학회논문지
    • /
    • 제18권6호
    • /
    • pp.1133-1142
    • /
    • 2023
  • 전력 계통에서 전력 용량의 급격한 증가는 고장 용량이 차단기의 차단 용량을 초과하게 함으로써 계통의 신뢰도를 심각하게 저하시킬 수 있다. 한류기는 고장 용량을 차단 용량 레벨로 제한함으로써 신뢰도를 개선할 수 있는 실질적이고 효과적인 방법이다. 본 연구에서는 한류기의 전력계통 적용 시 적용 방법론을 개발하는 데에 도움이 될 수 있도록 먼저, 한류기의 유형별 구조와 동작원리를 분석하였으며 주요 장단점들을 비교하였다. 다음, 한류기의 전력 계통에 대한 적용 효과를 검증하기 위해 한류기가 도입된 전력계통을 모델링하였다. 끝으로, EMTP-RV를 이용하여 3상 단락 고장을 모의한 후, 한류기의 적용 전과 후의 전류를 비교를 통해 한류기에 의해 고장 전류 감소하는 것을 확인함으로써 적용 효과를 검증할 수 있었다.

초전도 코일 적용으로 인한 DC 차단기의 차단 용량 증대 (Extension of Cut-off Capacity of DC Circuit Breaker due to Superconducting Coil Application)

  • 최혜원;최효상
    • 전기학회논문지
    • /
    • 제68권4호
    • /
    • pp.593-597
    • /
    • 2019
  • We proposed a current Interruption type DC superconducting circuit breaker(I-DC SCB), a protection device that combines the current limiting technology of a superconductor with the cut-off technology of circuit breaker. Unlike existing protective devices, the current I-DC SCB is a device that combines two protection functions, notably improving failure probability and operational reliability. It is also applicable to all DC systems, such as HV, MV, and LVDC, due to the ease in capacity increase. The 100 kV I-DC SCB was designed after taking into account the actual power system conditions, followed by an analysis of the transient characteristics and the breaking range of the limiter. The results of the analysis showed that the I-DC SCB had a fault current limit of about 75% at the rated voltage, and completed the cut-off operation within about 20 ms.