• 제목/요약/키워드: Current conditioning

검색결과 360건 처리시간 0.023초

Current Status of Layer Transfer Process in Thin Silicon Solar Cell : a review

  • U. Gangopadhyay;K. Chakrabarty;S.K. Dhungel;Kim, Kyung-Hae;Yi, Jun-Sin;D. Majumdar;H. Saha
    • Transactions on Electrical and Electronic Materials
    • /
    • 제5권2호
    • /
    • pp.41-49
    • /
    • 2004
  • Layer transfer process has emerged as a promising tool in the field of thin silicon solar cell technology. This process can use mono-crystalline silicon as a surface for the epitaxial growth of a thin layer of silicon. It requires some sort of surface conditioning of the substrate due to which the surface become suitable for homo-epitaxy and lift off after solar cell fabrication. The successful reuse of substrate has been reported. The use of the conditioned surface without any kind of epitaxial layer growth is also the issue to be addressed. This review paper basically describes the five most cost effective methods on which works are in progress. Several types of possible problems envisaged by different research groups are also incorporated here with necessary discussion. Work in Korea has already started in this area in collaboration IC Design and Fabrication Centre, Jadavpur University, India and that also has been mentioned.

주택용 단상 ESS-PCS의 전압손실과 직류링크 맥동을 고려한 직류측 배터리 사이즈 및 제어기 설계 (Design of DC Battery Size & Controller for Household Single-Phase ESS-PCS Considering Voltage Drop and DC Link Voltage Ripple)

  • 김용중;이진성;김효성
    • 전력전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.94-100
    • /
    • 2018
  • Generally, in a single-phase energy storage system (ESS) for households, AC ripple component with twice the fundamental frequency exists inevitably in the DC link voltage of single-phase PCS. In the grid-connected mode of a single-phase inverter, the AC ripple component in the DC link voltage causes low-order harmonics on grid-side current that deteriorates power quality on an AC grid. In this work, a control system adopting a feedforward controller is established to eliminate the AC ripple interference on the DC link side. Optimal battery nominal voltage design method is also proposed by considering the voltage loss and AC ripple voltage on DC link side in a single-phase ESS. Finally, the control system and battery nominal voltage design method are verified through simulations and experiments.

비절연형 양방향 탭인덕터 부스트 플라이백 컨버터 (Bidirectional Tapped-inductor Boost-Flyback Converter)

  • 김현우;전영태;박종후;전희종
    • 전력전자학회논문지
    • /
    • 제20권5호
    • /
    • pp.395-401
    • /
    • 2015
  • This paper proposes a new bidirectional DC-DC converter with high efficiency. The proposed converter is composed of a flyback and a tapped-inductor boost converter to satisfy extreme operating conditions with low cost. The outputs are connected in series to achieve a high-voltage step-up. In the reverse direction, the proposed converter has an extreme step-down voltage. In this study, the proposed converter was employed with a 100 W hardware prototype. To design the controller, a small-signal transfer function of the proposed converter is derived. For PV power conditioning systems, a maximum power point tracking method is applied with perturb and observe method. To verify the operation of the bidirectional power flow, the current controller is applied. All of the controllers are employed with a digital signal processor.

해인사 장경판전 환기창 형태에 따른 환기 성능에 대한 수치해석 연구 (A Numerical Study on the Effect of the Shape of Windows on the Ventilation Performance in the Storage Hall of Tripitaka Koreana at Haein Temple)

  • 허남건;이명성;양성진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.119-123
    • /
    • 2007
  • Ventilation performance in the storage hall of Janggyeongpan Jeon has maintained for more than 600 years. Janggyeongpan Jeon in Haein temple has window structure of bi-level ventilating opening which consists of upper and lower window. Also, different size and shape of windows are adopted for various locations of the hall. In the present study, to analyze effect of shape of windows on ventilation performance in the storage hall, various design alternatives were considered. Numerical analysis of ventilation in the storage hall was investigated under the same simulation condition except for the shape of windows. Through the comparison of numerical results for various window designs, it was evaluated that the current windows shape gives best ventilation performance.

  • PDF

중대형 보일러용 FD FAN의 베인 댐퍼 구조 개선에 관한 연구 (A Study on Efficiency Improvement of Vane Damper of Marine Boiler FD FAN)

  • 강봉성;박율민;김성문;정순재;유민경;장성철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.375-380
    • /
    • 2008
  • This study have processed the developing of vane damper with accurate control by using gear which is a flow-control equipment of marine boiler's FD fan on this research. For the developing of vane damper, we have corrected some problem from welding & assembly process by changing the design, and for the case of an emergency case, we have applied the easy disassembly & assembly on that vane damper. Compared to Rink type vane damper in current, we have focused on high efficiency with low price of that new developing damper. For selection of actuator, we have tried to find the propriety with our developing focus. Also, we have developed a jig of assembly processing for high productivity with quality, it caused the best assembly performance with heat-treated & processed parts.

  • PDF

도시철도 지하역사 공기조화기의 미세먼지 저감성능 개선을 위한 사전연구 (Pre-study for the improvement of air filtration performance in the air handling unit of subway station)

  • 강중구;신창헌;배성준;권순박;김세영;한석윤
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.541-545
    • /
    • 2008
  • Particulate matter (PM) is one of the major indoor air pollutants especially in the subway station in Korea. In order to remove PM in the subway station, several kinds of PM removal system such as roll-filter, auto-washable air filter, demister, and electrostatic precipitator re used in the air handling unit (AHU) of subway station. However, those systems are faced to operation and maintenance problems since the filter-regeneration unit consisting of electrical or water jet parts is malfunctioned due to the high load of particulates and the filter material needs periodic replacement. In this study, we surveyed the particle removal systems in order to develop the new system of particle removing can be adopted in the current AHU of subway station.

  • PDF

피치각 조정형 송풍-역풍 겸용 축류팬에서 배연용 피치각 선정을 위한 실험적 연구 (An Experimental Study on Selection Pitch Angle on backward flow of an Axial Fan with Adjustable Pitch Angle Blades)

  • 장택순;허진혁;문승재;이재헌;유호선;임윤철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.145-150
    • /
    • 2008
  • In this study, the experimental study has carried out to select pitch angle on the backward flow in an axial fan that has adjustable pitch blades. With the change of pitch angle of axial fan with adjustable blade, air flow rate, pressure and air flow direction can be changed. Because of this merit, adjustable axial fan can be used in the backward flow. For the selection of the backward flow pitch angle, fan performance test method is selected by KS B 6311. Dynamic pressure, static pressure, electric current and voltage are measured in each pitch angles of axial fan that are $36^{\circ}C$, $-16^{\circ}C$, $-21^{\circ}C$, $-26^{\circ}C$, $-31^{\circ}C$ and $-36^{\circ}C$. In the result of test, fan performance curves at several pitch angle has been investigated. Finally, pitch angle of $-26^{\circ}C$ has been selected to get largest flow rate at backward flow situation.

  • PDF

PEMFC 발전시스템용 고효율 PCS 개발에 관한 연구 (A Study on Development of High Efficiency PCS using in PEMFC Generation System)

  • 곽동걸;정원석;정도영;김춘삼;심재선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 에너지변화시스템부문
    • /
    • pp.266-268
    • /
    • 2009
  • In this paper, authors deal with a power conditioning system (PCS) of high efficiency for a proton exchange membrane fuel cell (PEMFC) generation system. Fuel cells are a direct current (DC) power generators. They generate electricity through an electrochemical process that converts the energy stored in a fuel directly into electricity. Fuel cells have many benefits, which produce no particulate matter, nitrogen or sulfur oxides. And they have few moving parts and produce little or no noise. When fueled by hydrogen, they yield only heat and water as byproducts. Their wide application can reduce our dependence on fossil fuels and foreign sources of petroleum. This paper studies on a novel PCS circuit topology of high efficiency using in PEMFC generation system The controlling switches in the PCS is operated to soft switching. Some digital simulation results and experimental results for the proposed PCS is confirmed to the validity of the analytical results.

  • PDF

Real-Time Maximum Power Point Tracking Method Based on Three Points Approximation by Digital Controller for PV System

  • Kim, Seung-Tak;Bang, Tae-Ho;Lee, Seong-Chan;Park, Jung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1447-1453
    • /
    • 2014
  • This paper proposes the new method based on the availability of three points measurement and convexity of photovoltaic (PV) curve characteristic at the maximum power point (MPP). In general, the MPP tracking (MPPT) function is the important part of all PV systems due to their power-voltage (P-V) characteristics related with weather conditions. Then, the analog-to-digital converter (ADC) and low pass filter (LPF) are required to measure the voltage and current for MPPT by the digital controller, which is used to implement the PV power conditioning system (PCS). The measurement and quantization error due to rounding or truncation in ADC and the delay of LPF might degrade the reliability of MPPT. To overcome this limitation, the proposed method is proposed while improving the performances in both steady-state and dynamic responses based on the detailed investigation of its properties for availability and convexity. The performances of proposed method are evaluated with the several case studies by the PSCAD/EMTDC$^{(R)}$ simulation. Then, the experimental results are given to verify its feasibility in real-time.

PV-BESS 시스템의 적정 PCS, 배터리용량 산정에 따른 최적 운영에 관한 연구 (A Study on the Optimal Operation According to Appropriate PCS and Battery Capacity Estimation of PV-BESS System)

  • 최윤석;나승유
    • 전기학회논문지
    • /
    • 제67권9호
    • /
    • pp.1174-1180
    • /
    • 2018
  • In December 2017, the government announced plans to increase the current proportion of renewable energy from 7% to 20% by 2030 through a plan called the Renewable Energy 3020 Implementation Plan. Therefore, the demand for installation of photovoltaic(PV), wind turbine(WT) and battery energy storage system(BESS) is expected to increase. In particular, the system combined with energy storage system(ESS) is expected to take up a large portion since PV and WT can receive high renewable energy certificates(REC) weights when combined with ESS. In this study, we calculate the optimal capacity of the power conditioning system(PCS) and the BESS by comparing the economical efficiency and maximize the efficiency of the PV-BESS system in which the PV and the BESS are connected. By analyzing the system marginal price(SMP) and REC, it maximize profits through application of REC weight 5.0 and optimal charge-discharge scheduling according to the SMP changes.