In this work, the scintillation properties of CsI:Na crystal were investigated as radiation detection sensor. This scintillation material was grown by a 2-zone vertical Bridgman method. Under X-ray excitation the crystal shows a broad emission band between 280 nm and 690 nm wavelength range, peaking at 413 nm. Energy resolution for $^{137}Cs$ 662 keV $\gamma$-rays of the crystal was measured to be 6.9 %(FWHM). At room temperature, the crystal exhibits three exponential decay time components. The fast and major component of scintillation time profile of the crystal emission decays with a 457 ns time constant. Absolute light yield of the crystal was estimated to be 53,000 ph/MeV using LAAPD. The sample crystal shows proportionality of 30 % in the measured energy range from 31 to 1,333 keV. And the $\alpha/\beta$ ratio of the crystal was 0.14.
The interaction of cyclosporine A (CsA), an immunosuppressant, with rat brain Kv1.5 (Kv1.5) channels, which were stably expressed in Chinese hamster ovary cells, was investigated using the whole-cell patch-clamp technique. CsA reversibly blocked Kv1.5 currents at +50 mV in a reversible concentrationdependent manner with an apparent $IC_{50}$ of 1.0μM. Other calcineurin inhibitors (cypermethrin, autoinhibitory peptide) had no effect on Kv1.5 and did not prevent the inhibitory effect of CsA. Fast application of CsA led to a rapid and reversible block of Kv1.5, and the onset time constants of the CsA-induced block were decreased in a concentration-dependent manner. The CsA-induced block of Kv1.5 channels was voltage-dependent, with a steep increase over the voltage range of channel opening. However, the block exhibited voltage independence over the voltage range in which channels were fully activated. The rate constants for association and dissociation of CsA were $7.0{\mu}M{-1}s^{-1}$ and $8.1s^{-1}$, respectively. CsA slowed the deactivation time course, resulting in a tail crossover phenomenon. Block of Kv1.5 by CsA was use-dependent. CsA also blocked Kv1.3 currents at +50 mV in a reversible concentration-dependent manner with an apparent $IC_{50}$ of $1.1{\mu}M$. The same effects of CsA on Kv1.3 were also observed in excised inside-out patches when applied to the internal surface of the membrane. The present results suggest that CsA acts directly on Kv1.5 currents as an open-channel blocker, independently of the effects of CsA on calcineurin activity.
Kim, Dae-Young;Choi, Yoon-Gi;Kyung, Tae-Suk;Hwang, Jun-Ha;Kim, Hyun Ji;Lee, Seung Chul;Kim, Kyu-Sung
Korean Journal of Otorhinolaryngology-Head and Neck Surgery
/
v.60
no.3
/
pp.107-111
/
2017
Background and Objectives The bedside head impulse test (bHIT) in bare eyes often overlooks possible vestibular losses by missing the corrective saccade. This is why it is necessary to compare bHIT against video head impulse test (vHIT), which is more accurate in identifying vestibular losses than the bedside test. Subjects and Method A total of 51 vHIT positive ears underwent the study, and out of those, 47 were diagnosed with dizziness. bHIT and vHIT were performed for patients, and the occurrence rate of overt saccade (OS) was calculated. Results Among the 51 vHIT positive ears, 33 (64.7%) were bHIT positive ears and 18 ears (35.3%) were bHIT negative. Patterns of positive vHIT were classified as A: no corrective saccade, B: covert saccade (CS) only, C: OS only, and D: CS with OS (CS+OS), which were 45 out of 51 ears (88%). The occurrence rate of OS was higher in the bHIT positive group than in the bHIT negative group (p=0.05), and higher in the CS negative group (CS-) than in the CS positive group (CS+) (p<0.001). Conclusion Possible causes of false negative results of bHIT are seen as following: the absence of corrective (covert and overt) saccade, the occurrence of CS only, and missing the OS during the bHIT (probably due to low occurrence rate of OS). The occurrence of CS should be considered as an important factor in false negative bHIT when lowering the occurrence rate of OS.
Kim, Jae-Cheon;Kim, Jong-Kyung;Kim, Soon-Young;Kim, Yong-Kyun;Lee, Woo-Gyo
Journal of Radiation Protection and Research
/
v.29
no.4
/
pp.263-268
/
2004
Using the Monte Carlo simulation, a study on the lion-proportionality of the prototype phoswich detector with $2'{\times}2'$ CSI(Tl) and plastic scintillator, which was made by KAERI, has been carried. The defector response functions (DRFs) calculated by simulations were compared with the experimental measurement on the $^{137}Cs\;and\;^{60}Co$. To precisely simulate the DRF for the phoswich, the CSI(Tl) non-proportionality was calculated using the electron response and the simplified electron cascade sequence for treating the photoelectric absorption event. The resulting DRFs of $^{137}Cs\;and\;^{60}Co$ sources obtained by simulations were compared with experiments for verification. For $^{137}Cs$, gamma-ray responses simulated by MCNP5 are generally good agreement with the measured ones. But the DRF of $^{60}Co$ does not match well with the results of experiment in the energy region below second peak due to the coincidence effect of two gamma-rays (1.17 MeV and 1.33 MeV). Through the analysis of the non-proportionality of CsI(Tl) in the prototype phoswich, the improved DRFs considering non-proportionality were produced and the simulation results were verified using the experimental measurements. However, to more precisely reproduce the DRF for the phoswich, further studies in relation to the electron channeling effect and the Doppler broadening effect of a scintillator are still needed as well as considering that effect of the transfer contribution.
In order to gain insight into the physiological responses of plants to high temperature stress, the effects of temperature on Chinese cabbage (Brassica campestris subsp. napus var. pekinensis cv. Detong) were investigated through analyses of photosynthesis and chlorophyll fluorescence under 3 different temperatures in the temperature gradient tunnel. Growth (leaf length and number of leaves) during the rosette stage was greater at ambient $+4^{\circ}C$ and ambient $+7^{\circ}C$ temperatures than at ambient temperature. Photosynthetic $CO_2$ fixation rates of Chinese cabbage grown under the different temperatures did not differ significantly. However, dark respiration rate was significantly higher in the cabbage that developed under ambient temperature relative to elevated temperature. Furthermore, elevated growth temperature increased transpiration rate and stomatal conductance resulting in an overall decrease of water use efficiency. The chlorophyll a fluorescence transient was also considerably affected by high temperature stress; the fluorescence yield $F_J$, $F_I$, and $F_P$ decreased considerably at ambient $+4^{\circ}C$ and ambient $+7^{\circ}C$ temperatures, with induction of $F_K$ and decrease of $F_V/F_O$. The values of RC/CS, ABS/CS, TRo/CS, and ETo/CS decreased considerably, while DIo/CS increased with increased growth temperature. The symptoms of soft-rot disease were observed in the inner part of the cabbage heads after 7, 9, and/or 10 weeks of cultivation at ambient $+4^{\circ}C$ and ambient $+7^{\circ}C$ temperatures, but not in the cabbage heads growing at ambient temperature. These results show that Chinese cabbage could be negatively affected by high temperature under a future climate change scenario. Therefore, to maintain the high productivity and quality of Chinese cabbage, it may be necessary to develop new high temperature tolerant cultivars or to markedly improve cropping systems. In addition, it would be possible to use the non-invasive fluorescence parameters $F_O$, $F_V/F_M$, and $F_V/F_O$, as well as $F_K$, $M_O$, $S_M$, RC/CS, ETo/CS, $PI_{abs}$, and $SFI_{abs}$ (which were selected in this study), to quantitatively determine the physiological status of plants in response to high temperature stresses.
Journal of the Institute of Electronics Engineers of Korea SD
/
v.41
no.5
/
pp.99-105
/
2004
A shared-capacitor charge-sharing ROM (SCCS-ROM) using dummy bit lines is proposed. The SCCS-ROM reduces the bit line swing voltage using the charge-sharing technique of the conventional charge-sharing ROM (CS-ROM). Although the CS-ROM needs three small capacitors per output bit, the proposed SCCS-ROM shares the capacitors so that it needs only three capacitors. The SCCS-ROM implements the capacitors using dummy bit lines. This not only increases noise immunity but also reduces power. A SCCS-ROM with 8K${\times}$15bits implemented in a 0.35${\mu}{\textrm}{m}$ CMOS process. The SCCS-ROM consumes 8.63㎽ at 100MHz with 3.3V The simulation results show that the SCCS-ROM reduces 8.4% power compared to the CS-ROM.
Lee Eun-Ju;Lee Eun-Sil;Hah Jung-Hi;Kim Yong-Jin;Park Yong-Hoon
Childhood Kidney Diseases
/
v.4
no.2
/
pp.127-135
/
2000
Purpose: Cyclosporine(CsA) is a potent immunosuppressant but the use of CsA is associated with various side effects, especially nephrotoxicity. In tile kidney, salt depletion activates tile renin-angiotensin-aldosteron(RAS) system and accentuates chronic CsA nephropathy. We postulate that angiotensin converting enzyme inhibitors(ACEI) can prevent chronic CsA nephropathy, since ACEI may inhibit this cascades. This study was aimed to assess the effect of ACEI on chronic cyclosporin nephropathy in salt depleted rats. Methods: 36 Fischer-344 rats were divided into 6 goups. Group I received normal salt diet(NSD). Group II received a low salt diet(LSD). Group III received CsA with a NSD. Group IV received CsA with a LSD. Group V received NSD+CsA with ACEI. Group VI received LSD+CsA with ACEI. Rats were sacrificed after six weeks and the glomerular filtration rate(GFR), serum sodium, potassium and whole blood cyclosporine levels were measured. Renal tissues me sampled for the observation of histological changes. Results: No differences in blood CsA level & serum sodium were found between groups during the course of this experiment. Serum potassium in group VI was significantly increased compared with group IV and V (P<0.05). In groups treated with CsA only and in those where CsA was combined with ACEI, GFR was found to be significantly more decreased in LSD than NSD, and GFR in group V was significantly decreased in comparison with group III (P<0.05). Renal histologic lesions associated with CsA which consisted of cortical interstitial fibrosis, tubular atrophy and hyalinization of arterioles were more severe in tile LSD group. But, no differences were observed between tile groups treated with CsA and ACEI, and the groups treated with only CsA. Conclusion: Salt depletion associated with the activation of the RAS system accentuated chronic CsA nephrotoxicity, but, ACEI could not reduce the functional and morphological changes of salt depleted kidneys, in which nephropathy can be exacerbated in spite of the blocking of the angiotensin II pathway. further studies are required to elucidate whether Am ameliorated the effect of salt-depleted CsA nephrotoxicity upon the effective renal blood flow.
1-$\beta$-Methyl carbapenem-2-substituted pyrroudine derivatives. CRB 529 and CRB 550, were synthesized as investigational carbapenem derivatives. It has been reported that the in vitro antibacterial activities of the compounds against G(+) and G(-) bacteria were almost the same or more effective than those of imipenem (IPM) and meropenem (MEPM), and also showed better in vivo efficacy than MEPM and inlipeneni/cilastatin (IPM/CS) against representative G(-) organisms, P. aeruginosa and MRSA organisms, S. aureus. The antibacterial activities, pharmacokinetics and protective efficacy of IPM/CS and CRB 529 and CRB 550 wereconducted after subcutaneous or intravenous administration to mice and rats. The pharmacokinetic parameters of CRB 529 and CRB 550 in mice were as follows: the observed maximal serum concentrations (C$_{max}$) following I.V. administration were 87.5 and 101 $\mu\textrm{g}$/ml for CRB 529 and CRB 550, respectively, and 63.6 $\mu\textrm{g}$/ml for IPM/CS. The half-lives (t$_{1/2}$) were 14.0 and 12.0 n-dn for CRB 529 and CRB 550, respectively, and 14.8 min for IPM/CS. In rats, $C_{max}$ after I.V. administration were 74.0 and 91.8 $\mu\textrm{g}$/ml for CRB 529 and CRB 550, respectively, and 41.2 $\mu\textrm{g}$/ml for IPM/CS. The tissue levels of CRB 529 and CRB 550 and IPM/CS after I.V. administration at a dose of 20 mg/kg decreased by the following order: lung, heart, kindney, liver and spleen for CRB 529, lddney, liver. lung, heart and spleen for CRB 550 and kidney, lung, liver, heart, spleen and brain for IPM/CS. In systemic infection, CRB 529 and CRB 550 showed excellent efficacies against P. aeruginosa and S. aureus (MRSA) at a dose of 5 mg/kg. The PD$_{50s}$ were 0.80, 0.36 mg/kg for CRB 529 and CRB 550, respectively, and 3.22 mg/kg for IPM/CS against P. aeruginosa. The corresponding values against S. aureus (MRSA) were 76.0, 55.3 mg/kg for CRB 529 and CRB 550, respectively, and 146 mg/kg for IPM/CS. In local infection, the antibacterial activities of CRB 529 and CRB 550 were more effective than those of IPM/CS against intrarenal infection with E. coli and P. aeruginosa and also showed as effective as IPM/CS against respiratory tract infection with E. coli and P. aeruginosa at a dose of 5 mg/kg.
Kim, S.H.;Han, S.H.;Kim, K.R.;Kang, H.D.;Choi, Y.S.;Lee, Y.B.;Lee, J.M.
Journal of Sensor Science and Technology
/
v.6
no.4
/
pp.290-297
/
1997
In this study, the radiation monitoring system using CsI(TI) scintillation counter is developed for the measurement of radiation distribution in the field of high dose level. When the inner diameter of collimator is 8 mm, we have realized the optimum detecting efficiency and spatial resolution. At that time, the position resolution was 10 cm at 1 m from the system. And experimental results indicated that the energy resolution of the system were 10 % for 662 keV of Cs-137, 7.6 % for 1.17 MeV of Co-60, and 5.8 % for 1.33 MeV of Co-60. Also, we have shown that the real radiation distribution images may be obtained by our measurement system.
This study compared PENELOPE with measured values from low energy peak to high energy peak to reduce peak to compton ratio and continuum background spectrum using $^{60}Co$, $^{137}Cs$ and mixed volume source. In addition, the change in backscattering and compton edge efficiency was compared with that of PENELOPE through changes in the vicinity of low energy. The results from the mixed volume source are applied to the soil samples to determine how much the minimum detection limits of the soil samples are reduced in the suppression and unsuppressed mode. The compton suppression of the low energy region of $^{60}CO$ (1,173 keV) was considerable, and the Compton edge RF for the $^{137}Cs$ (661 keV) peak was 2.8. In particular, the $^{60}Co$ source emits coincidence gamma rays of 1,173.2 keV and 1,332.5 keV, so compton inhibition was reduced by approximately 21%. RF of compton edges of 1,173 keV and 1,332 keV emitted from a $^{60}Co$ source was 3.2 and 3.4, and the peak to compton edge ratio was improved to 8: 1. And Compared with Penelope, the uncertainty was well within 2%. In compton unsuppressed mode, MDA values of 661 keV, 1,173 keV and 1,332 keV were 0.535, 0.173 and 0.136 Bq/kg, respectively, but decreased in compton suppressed mode to 0.121, 0.00826 and 0.00728 Bq/kg. Thus, Compton suppressed could reduce the background radioactivity and the radioactivity contained in the detector itself.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.