• 제목/요약/키워드: CsI(Tl)

검색결과 66건 처리시간 0.031초

$BaF_2$ 검출기의 시간과 에너지 특성연구 (A Study on the Energy and Time Characteristics of $BaF_2$ Scintillation Detector)

  • 주관식;박일진;김종호;남기용;백승화
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권3호
    • /
    • pp.267-272
    • /
    • 1997
  • 3.6cm${\times}$2.0cm (지름 ${\times}$ 두께) 크기의 $BaF^2$ 섬광체로 검출기를 제작하여 감마 카메라등 의료용 진단장치에서 센서로 사용되고 있는 NaI(씨)검출기와 방사선 검출특성을 비교하여 보았다. 특정에 사용된 선원은 $^{22}Na,\;^{54}Mn,\;^{57}Co,\;^{137}Cs$${\gamma}$선 방출선원으로 검출기와 선원간의 거리를 7cm로 유지하였다. 시간특성을 분석하기 위하여 511keV의 양전자 방출선원을 사용하여 NaI(Tl)(1" ${\times}$ 1"), NaI(Tl)(3" ${\times}$ 3")순으로 $BaF^2$가 가장 빠르게 나타났으며, $BaF^2$ 검출기의 효율은 500keV에서 가장 높게 측정되었다.

  • PDF

Ambient dose equivalent measurement with a CsI(Tl) based electronic personal dosimeter

  • Park, Kyeongjin;Kim, Jinhwan;Lim, Kyung Taek;Kim, Junhyeok;Chang, Hojong;Kim, Hyunduk;Sharma, Manish;Cho, Gyuseong
    • Nuclear Engineering and Technology
    • /
    • 제51권8호
    • /
    • pp.1991-1997
    • /
    • 2019
  • In this manuscript, we present a method for the direct calculation of an ambient dose equivalent (H* (10)) for the external gamma-ray exposure with an energy range of 40 keV to 2 MeV in an electronic personal dosimeter (EPD). The designed EPD consists of a 3 × 3 ㎟ PIN diode coupled to a 3 × 3 × 3 ㎣ CsI (Tl) scintillator block. The spectrum-to-dose conversion function (G(E)) for estimating H* (10) was calculated by applying the gradient-descent method based on the Monte-Carlo simulation. The optimal parameters for the G(E) were found and this conversion of the H* (10) from the gamma spectra was verified by using 241Am, 137Cs, 22Na, 54Mn, and 60Co radioisotopes. Furthermore, gamma spectra and H* (10) were obtained for an arbitrarily mixed multiple isotope case through Monte-Carlo simulation in order to expand the verification to more general cases. The H* (10) based on the G(E) function for the gamma spectra was then compared with H* (10) calculated by simulation. The relative difference of H* (10) from various single-source spectra was in the range of ±2.89%, and the relative difference of H* (10) for a multiple isotope case was in the range of ±5.56%.

Development of Spectroscopy Toolkit for Spectrum Measurement Experiments Using a CsI(Tl)/PIN Diode Detector

  • Nam, Young-Mi;Kim, Han-Soo;Ha, Jang-Ho;Lee, Jae-Hyung
    • Journal of Radiation Protection and Research
    • /
    • 제35권2호
    • /
    • pp.77-80
    • /
    • 2010
  • The spectroscopy toolkit has been developed and tested. The toolkit consists of a CsI(Tl)/PIN diode detector, integrated electronics, and a multi.channel.analyzer and its size was 40 cm(width) by 20 cm(length) by 6 cm(high). It is compact, very portable and simpler and cheaper compared to the conventional spectroscopy system. The gamma energy resolutions of the toolkit were 7.9% for the 660 keV of $^{137}Cs$ and 4.9% for 1,332 keV of $^{60}Co$ respectively. The linearity for gamma energies was good. When the energy spectrum of a ceramic sample containing $^{232}Th$ was measured with the spectroscopy toolkit for 20 minutes, there were significant peaks of the heavy metal. These results show that the resolution of the spectroscopy toolkit is sufficient to accumulate a quality spectrum in a few minutes by using weak, encapsulated commercial sources. Furthermore a toolkit experiment that how to measure energy spectra using the toolkit, and how to identify specific isotopes in a pottery piece, could be widely adopted for education and even for more sophisticated and higher level experiments.

Animated Game-Based Learning of Data Structures In Professional Education

  • Waseemullah, Waseemullah;Kazi, Abdul Karim;Hyder, Muhammad Faraz;Basit, Faraz Abdul
    • International Journal of Computer Science & Network Security
    • /
    • 제22권9호
    • /
    • pp.1-6
    • /
    • 2022
  • Teaching and learning are one of the major issues during this pandemic (COVID-19). Since the pandemic started, there are many changes in teaching and learning styles as everything related to studies started online. Game-Based Learning has got remarkable importance in the educational system and pedagogy as an effective way of increasing student inspiration and engagement. In this field, most of the work has been carried out in digital games. This research uses an Animated Game-Based Learning design in enhancing student engagement and perception of learning. In teaching Computer Science (CS) concepts in higher education, to enhance the pedagogy activities in CS concepts, more specifically the concepts of "Data Structures (DS)" i.e., Array, Stack, and Queue concepts are focused. This study aims to observe the difference in students' learning with the use of different learning methods i.e., the traditional learning (TL) method and the Animated Game-Based Learning (AGBL) Method. The experimental results show that learning DS concepts has been improved by the AGBL method as compared to the TL method.

Development of a wireless radiation detection backpack using array silicon-photomultiplier (SiPM)

  • Kim, Jeong Ho;Back, Hee Kyun;Joo, Koan Sik
    • Nuclear Engineering and Technology
    • /
    • 제52권2호
    • /
    • pp.456-460
    • /
    • 2020
  • In this research, a radiation detection backpack to be used discreetly or by a wide range of users was developed using array silicon-photomultiplier (SiPM) and CsI (Tl), and its characteristics were evaluated. The R-squared value, which indicates the responsiveness of a detector based on the signal intensity, was determined to be 0.981, indicating a good linear responsivity. The energy resolutions for gamma radiation energies of Co-57 (122 keV), Ba-133 (356 keV), Cs-137 (662 keV), and Co-60 (1332 keV) were found to be 13.40, 10.50, 6.77, and 3.16%, respectively. These results confirm good energy resolution characteristics. Furthermore, in the case of mixed sources, the gamma radiation peaks were readily distinguishable, and the R-squared value for energy linearity was calculated to be 0.999, demonstrating an exceptional energy linearity. Further research based on the results of this study would enable the commercialization of lightweight SiPM-based wireless radiation detection backpacks that can be used for longer durations by replacing the photomultiplier tube, which is mainly used as the optical sensor in existing radiation detection backpacks.

양성자 선량 분포 검증을 위한 즉발감마선 분포측정 장치 최적화 연구 (Study on Optimization of Detection System of Prompt Gamma Distribution for Proton Dose Verification)

  • 이한림;민철희;박종훈;김성훈;김찬형
    • 한국의학물리학회지:의학물리
    • /
    • 제23권3호
    • /
    • pp.162-168
    • /
    • 2012
  • 양성자 치료에서 치료의 목표를 달성하고 환자의 안전을 제고하기 위해 인체 내 양성자 빔의 분포를 확인하는 것이 중요하다. 양성자 선량분포와 밀접한 관계가 있는 즉발감마선의 2차원 분포 측정을 위하여 본 연구팀에서는 다수의 CsI(Tl) 섬광체가 1차원 종형으로 배열된 검출기 배열과 집속장치 및 다채널 신호처리 장치로 이루어진 측정장치를 개발하고 있다. 이에 본 연구에서 몬테칼로 기반의 MCNPX 코드를 이용하여 최적화된 측정 장치를 설계하고자 하였다. 즉발감마선을 효과적으로 측정하기 위해 CsI(Tl) 섬광체의 크기를 $6{\times}6{\times}50mm^3$로 결정하였으며, 배경감마선의 영향을 최소화하고 빔의 진행방향에서 수직방향으로 발생하는 즉발감마선만 측정하기 위해 집속장치의 구멍 크기는 면적 $6{\times}6mm^2$, 길이 150 mm로 최적화되었다. 150 MeV 양성자 빔에 대한 성능 예측 전산모사연구를 수행한 결과, 본 연구에서 최적화된 측정 장치를 통해 즉발감마선 2차원 분포를 측정할 수 있었으며, 1 mm 오차범위에서 양성자 빔의 비정을 결정할 수 있었다. 이를 바탕으로 현재 다채널의 신호처리 장치를 개발하고 있으며 실제 양성자 빔을 이용한 즉발감마선 분포측정을 통해 측정 장치의 성능을 검증할 것이다.

감마선 분광분석을 위한 실리콘 광 증배소자 기반 Ce:GAGG 섬광검출기의 분광특성 연구 (Spectroscopic Properties of a Silicon Photomultiplier-based Ce:GAGG Scintillation Detector and Its Applicability for γ-ray Spectroscopy)

  • 박혜민;김정호;김동성;주관식
    • Journal of Radiation Protection and Research
    • /
    • 제40권2호
    • /
    • pp.73-78
    • /
    • 2015
  • 본 연구에서는 실리콘 광 증배소자(Silicon photomultiplier)와 Ce:GAGG 섬광체 단결정을 이용한 섬광검출기를 제작하고, 감마선 분광특성 분석을 통해 기존에 상용화된 LYSO, CsI:Tl 섬광체와의 분광특성을 비교하였다. 섬광체 단결정의 크기는 $3{\times}3{\times}20mm^3$ 이며 $3{\times}3mm^2$ 실리콘 광 증배소자를 이용하여 섬광검출기를 제작한 후, 표준 감마선원인 $^{133}Ba$, $^{22}Na$, $^{137}Cs$, $^{60}Co$에 대한 에너지 분해능을 각각 측정하고 비교하였다. 그 결과 Ce:GAGG 섬광검출기의 감마선에 대한 에너지 분해능은 $^{133}Ba$ 0.356 MeV에서 13.5%, $^{22}Na$ 0.511 MeV에서 6.9%, $^{137}Cs$ 0.662 MeV에서 5.8% 그리고 $^{60}Co$ 1.33 MeV에서 2.3%의 분광 특성을 확인 할 수 있었다.

CsI 단결정 섬광체의 열형광특성과 육성조건 (TL Characteristics of CsI Single Crystal Scintillators and their Growth Conditions)

  • 도시홍;이우교;홍시영;방신응;강갑중;김도성;김완;강희동
    • 센서학회지
    • /
    • 제7권4호
    • /
    • pp.234-242
    • /
    • 1998
  • Czochralski 방법을 사용하여 격자결함이 적은 CsI 단결정 섬광체를 육성하기 위한 최적육성조건을 구하기 위하여 광투과율의 변화와 열형광특성을 이용하였다. 결정화과정을 반복할수록 불필요한 불순물 분포와 열형광강도 및 glow 피이크의 수가 감소하였다. 결정성장방향은 (110)이었고, 육성한 CsI의 결정구조는 체심입방체이었다. 그리고 격자상수는 $4.568{\AA}$ 임을 확인할 수 있었다. CsI:3rd의 활성화 에너지(trap깊이)는 약 0.45 eV 이었고, 주파수인자는 $5.18{\times}10^5\;sec^{-1}$이었다.

  • PDF

다중에너지 영상 획득을 위한 Depth-Encoding 고분해능 단일광자단층촬영 검출기 개발: 몬테칼로 시뮬레이션 연구 (Development of a High Resolution SPECT Detector with Depth-encoding Capability for Multi-energy Imaging: Monte Carlo Simulation)

  • 백철하;황지연;이승재;정용현
    • 한국의학물리학회지:의학물리
    • /
    • 제21권1호
    • /
    • pp.93-98
    • /
    • 2010
  • 본 연구에서는 I-125 (35 keV) 와 Tc-99m (140 keV)에 대해 고해상도를 지닌 SPECT 영상을 동일한 검출기로 획득하는 방법을 제시하였고, 이를 몬테칼로 시뮬레이션 코드인 DETECT2000과 GATE를 이용하여 검증하였다. 제안된 검출기는 두께 3.0 mm의 CsI (Tl) 블록형 섬광체와 하마마츠사의 H8500C PSPMT로 이루어져 있다. 35 keV 감마선을 방출하는 I-125 핵종을 영상화할 때는 두꺼운 섬광체를 사용 할 경우, 일반적인 앵거방법으로는 빛 퍼짐이 많아지기 때문에 내인성 공간분해능이 저하되지만, 최대우도 함수와 색인테이블을 사용하여 감마선 반응 위치를 추적하면 내인성 공간분해능을 향상시킬 수 있다. DETECT2000 시뮬레이션 결과 1.0 mm 이내의 내인성 공간분해능을 획득하였다. 140 keV를 방출하는 Tc-99m를 영상화할 경우에는 I-125 전용인 1.0 mm 두께의 섬광체를 사용하였을 경우보다 3.0 mm 두께의 섬광체를 사용하였을 때 2.3배 이상 향상된 민감도를 보였다. 본 연구에서 제안한 검출기의 장점은 저에너지의 I-125 선원에 대해 상대적으로 두꺼운 섬광체를 사용하더라도 최대우도함수를 사용하기 때문에 분해능의 감소가 없다는 점과 Tc-99m 선원에 대해 민감도의 저하가 적다는 점이다. 본 연구에서 제안한 검출기를 사용하면 고에너지와 저에너지를 가진 핵종을 모두 영상화할 수 있다.

이중 산란형 컴프턴 카메라 구성 검출기 성능 평가 (Performance Evaluation of Component Detectors of Double-scattering Compton Camera)

  • 서희;박진형;김찬형;이주한;이춘식;이재성
    • Journal of Radiation Protection and Research
    • /
    • 제35권2호
    • /
    • pp.69-76
    • /
    • 2010
  • 현재 개발중에 있는 이중 산란형 컴프턴 카메라는 두 대의 산란부 검출기(양면 실리콘 스트립 검출기, DSSD)와 하나의 흡수부 검출기(NaI(Tl) 섬광 검출기)로 구성되며, 소형이면서도 높은 영상해상도를 제공할 수 있는 구조를 가지고 있다. 본 연구에서는 이중 산란형 컴프턴 카메라를 구성하고 있는 감마선 검출기들의 에너지 분해능 및 시간 분해능을 평가하고, 산란부 검출기의 에너지 분해능에 영향을 미치는 인자들을 등가 노이즈 전하(equivalent noise charge)를 통하여 분석하였다. DSSD-1은 평균적으로 59.5 keV 피크($^{241}Am$)에 대하여 $25.2keV{\pm}0.8keV$ FWHM의 에너지 분해능을 보였으며, DSSD-2는 $31.8keV{\pm}4.6keV$ FWHM의 에너지 분해능 지니고 있는 것으로 확인되었다. DSSD의 시간 분해능은 57.25 ns FWHM으로 평가되었고, NaI(Tl) 섬광 검출기의 시간 분해능은 7.98 ns FWHM이었다. 또한 이중산란형 컴프턴 카메라를 이용하여 $^{137}Cs$ 점선원에 대한 컴프턴 영상을 획득한 후 성능을 평가하였다. 이번 실험을 통해서 영상해상도 8.4 mm FWHM (각 분해능 $8.1^{\circ}$ FWHM)을 획득하였고, 영상감도는 $1.5{\times}10^{-7}$(고유 효율=$1.9{\times}10^{-6}$)으로 나타났다.