• Title/Summary/Keyword: Critical factor

Search Result 3,012, Processing Time 0.031 seconds

A Continuous Conduction mode/Critical Conduction Mode Active Power Factor Correction Circuit with Input Voltage Sensor-less Control (입력전압을 감지하지 않는 전류연속/임계동작모드 Active Power Factor Correction Circuit)

  • Roh, Yong-Seong;Yoo, Changsik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.8
    • /
    • pp.151-161
    • /
    • 2013
  • An active power factor correction (PFC) circuit is presented which employs a newly proposed input voltage sensor-less control technique operated in continuous conduction mode (CCM) and critical conduction mode (CRM). The conventional PFC circuit with input voltage sensor-less control technique degrades the power factor (PF) under the light load condition due to DCM operation. In the proposed PFC circuit, the switching frequency is basically 70KHz in CCM operation. In light load condition, however, the PFC circuit operates in CRM and the switching frequency is increased up to 200KHz. So CCM/CRM operation of the PFC circuit alleviates the decreasing of the PF in light load condition. The proposed PFC controller IC has been implemented in a $0.35{\mu}m$ BCDMOS process and a 240W PFC prototype is built. Experimental results shows the PF of the proposed PFC circuit is improved up to 10% from the one employing the conventional CCM/DCM dual mode control technique. Also, the PF is improved up to 4% in the light load condition of the IEC 61000-3-2 Class D specifications.

Development and Validation of a Korean Nursing Work Environment Scale for Critical Care Nurses (한국형 중환자실 간호근무환경 측정도구 개발 및 평가)

  • Lee, Hyo Jin;Moon, Ji Hyun;Kim, Se Ra;Shim, Mi Young;Kim, Jung Yeon;Lee, Mi Aie
    • Journal of Korean Clinical Nursing Research
    • /
    • v.27 no.3
    • /
    • pp.279-293
    • /
    • 2021
  • Purpose: The purpose of this study was to develop a Korean nursing work environment scale for critical care nurses (KNWES-CCN) and verify its validity and reliability. Methods: A total of 46 preliminary items were selected using content validity analysis of experts on 64 candidate items derived through literature reviews and in-depth interviews with critical care nurses. 535 critical care nurses from 21 hospitals responded to the preliminary questionnaire from February to March 2021. The collected data were analysed using construct, convergent and discriminant validities, and internal consistency and test-retest reliability. Results: The 23 items in 4 factors accounted for 55.6% of the total variance were identified through item analysis and exploratory factor analysis (EFA). EFA was performed with maximum likelihood method including direct oblimin method. In the confirmatory factor analysis, KNWES-CCN consisted of 21 items in 4 factors by deleting the items that were not meet the condition that the factor loading over .50 or the squared multiple correlation over .30. This model was considered to be suitable because it satisfied the fit index and acceptable criteria of the model [𝒳2=440.47 (p<.001), CMIN/DF=2.41, GFI=.86, SRMR=.06, RMSEA=.07, TLI=.90, CFI=.91]. The item total correlation values ranged form .32 to .73 and its internal consistency was Cronbach's α=.92. The reliability of the test-retest correlation coefficient was .72 and the intra-class correlation coefficient was .83. Conclusion: The KNWES-CCN showed good validity and reliability. Therefore, it is expected that the use of this scale would measure and improve nursing work environment for critical care nurses in Korea.

Application of Critical Damage Value to Continuous Drawing Process using FEM (연속 인발공정에서 유한요소법을 이용한 Critical Damage Value 의 적용)

  • 박동인;김병민;고대철
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.10a
    • /
    • pp.291-295
    • /
    • 2003
  • The occurrence of ductile fracture is the working limit of many metal forming processes. It is necessary to predict the criteria and to apply the condition in a process design. Over the years. the way for clarifying conditions have been studied and presented. However such a way needs lots of experiments and analysis. In this study, in order to determine the critical damage value of a used material Cu 4N, it was performed a tensile test and FEM analysis by using DEFORM 2D. For applying the obtained critical damage value it was also performed a upsetting test by using DEFORM 2D. The way of determining a critical damage value which is presented in this study will make possible to find easily it which is one of the working limit factor. And the way of determining a critical damage value will make possible to find in multi-pass drawing process.

  • PDF

Correlation Verification and Revision of Critical Power in a Hemispherical Narrow Gap (구형 간극에서의 임계출력에 관한 상관식 검증 및 보완)

  • Ha Kwang-Soon;Park Rae-Joon;Kim Sang-Baik;Kim Hee-Dong
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.411-414
    • /
    • 2002
  • The CHFG(Critical Heat Flux in Cap) test results have been evaluated to quantify the critical powers in hemispherical narrow gaps and Park's correlation has been verified. For verification of the Park's correlation, the critical powers in hemispherical narrow gaps have been measured using water at a pressure of 0.1-0.3 WPa for the hemispherical gap thickness of 1.0mm, and the heated top diameter of 238mm The measured critical powers were compared with Park's and Monde's correlation. As a results, the Park's correlation was most accurate of other correlations, however, estimated the critical powers somewhat larger than measured ones. So, it was suggested that the diameter factor in Park's correlation should be revised.

  • PDF

Implementation of Digital Control for Critical Conduction Mode Power Factor Correction Rectifier

  • Shin, Jong-Won;Baek, Jong-Bok;Cho, Bo-Hyung
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.147-148
    • /
    • 2011
  • In this paper, implementation of digital control for critical conduction mode power factor correction (PFC) rectifier is presented. Critical conduction mode is widely used in medium and low power conversion application due to its minimized MOSFET turn-on loss and diode reverse-recovery problem. However, it needs additional zero current detection circuit and maximum frequency limit to properly turn the MOSFET on and avoid the excessive switching loss in light load operation. This paper explains the digital IC implementation and verifies its operation with 200-W prototype PFC rectifier.

  • PDF

Elastic Critical Load and Effective Length Factors of Continuous Compression Member by Beam Analogy Method

  • Lee, Soo-Gon;Kim, Soon-Chul
    • Architectural research
    • /
    • v.2 no.1
    • /
    • pp.47-54
    • /
    • 2000
  • The critical load of a continuous compression member was determined by the beam-analogy method. The proposed method utilizes the stress-analysis results of the analogous continuous beam, where imaginary concentrated lateral load changing its direction is applied at each midspan. The proposed method gives a lower bound error of critical load and can predict the span that buckles first. The effective length factors for braced frame columns can be easily determined by the present method, but result in the upper bound errors in all cases, which can lead to a conservative structural design.

  • PDF

Prolyl 4 Hydroxylase: A Critical Target in the Pathophysiology of Diseases

  • Kant, Ravi;Bali, Anjana;Singh, Nirmal;Jaggi, Amteshwar Singh
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.17 no.2
    • /
    • pp.111-120
    • /
    • 2013
  • Prolyl 4 hydroxylases (P4H) are iron- and 2-oxoglutamate-dependent dioxygenase enzymes and hypoxia-inducible transcription factor (HIF)-P4Hs play a critical role in the regulating oxygen homeostasis in the local tissues as well in the systemic circulation. Over a period of time, a number of prolyl hydroxylase inhibitors and activators have been developed. By employing the pharmacological tools and transgenic knock out animals, the critical role of these enzymes has been established in the pathophysiology of number of diseases including myocardial infarction, congestive heart failure, stroke, neurodegeneration, inflammatory disease, respiratory diseases, retinopathy and others. The present review discusses the different aspects of these enzymes including their pathophysiological role in disease development.

A Study on Critical Success Factor Analysis and its Usage : An Aplication Study to the Steel Industry in Korea (주요성과요인분석과 그 활용방안에 관한 연구 :한국 철강산업에의 적용사례)

  • 문태수;신영종
    • Korean Management Science Review
    • /
    • v.8 no.1
    • /
    • pp.13-25
    • /
    • 1991
  • Over the past few years, there has been a growing interest in using information technology for competitive advantage. A sustainable advantage is the key to the survival and growth of a firm. The successful implementation of information technology is dependent on efficient information systems planning. But the correct and complete information, requirements for effective information systems planning are frequently very difficult to obtain. In this paper the Critical Success Factors(CSF) method was employed as a means of managerial information requirements analysis for information systems planning in Korea's steel industry. CSFs are one of the few areas of activity that must go well to ensure the success of an organization. This paper addresses the concept and hierarchy of CSF analysis as a methodology in identifying corporate information needs and concludes with the use and benefit of results of CSF analysis.

  • PDF

A study on the Determination of Fractuye Parameters for Rubber Toughened Polymeric Materials Using Instrumented Charpy Impact Test (샤피충격시험기를 이용한 고무보강 폴리머재료의 파괴인자 결정에 관한연구)

  • Choi, Young-Sic;Park, Myung-Kyun;Bahk, S.M.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.389-394
    • /
    • 2001
  • The notched Charpy and Izod impact tests arc the most prevalent techniques used to characterize the effects of high impulse loads on ploymeric materials. An analysis method for rubber toughened PVC is suggested to evaluate critical strain energy release rates(Gc) from the Charpy impact energy measurements. An Instrumented Charpy impact tester was used to extract ancillary information concerning fracture properties in addition to total fracture properties and maximum critical loads. The stress intensity factor Kd was computed for varying amounts of rubber contents from the obtained maximum critical loads and also toughening effects were investigated as well.

  • PDF

Critical Factors Affecting Consumer Acceptance of Online Health Communication: An Application of Service Quality Models

  • Lee, Jung Wan
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.4 no.3
    • /
    • pp.85-94
    • /
    • 2017
  • The paper examines critical factors affecting consumer behavioral intentions in accepting online health communication through social networking sites. Unlike recent research under this topic, the paper assimilates some components of service quality dimensions and consumer behavior theories. The paper employs factor analysis and structural equation modelling analysis with latent variables to identify critical factors from the survey data collected from Korean consumers. The results of the study identifies three major constructs: consumer needs for health information, the perceived value of tangible attributes of health information providers, and the perceived value of intangible attributes of health information providers. The results show that consumer needs for health information and the tangible and intangible attributes of health information providers should be considered as important antecedents of accepting online health communication through social networking sites. The findings suggest that the success of online health communication via social networking sites largely depends on the tangible and intangible attributes of health information providers.