• 제목/요약/키워드: Critical Factor of Using

검색결과 1,131건 처리시간 0.028초

Development of Critical Heat Flux Correction Factor for Water under Flow Oscillation Conditions

  • Kim, Yun-Il;Baek, Won-Pil;Chang, Soon-Heung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 추계학술발표회논문집(1)
    • /
    • pp.242-247
    • /
    • 1996
  • Flow oscillations in boiling channels induces a drastic reduction of the (critical heat flux) CHF or premature burnout. However, most of CHF works and correlations have been focused on stable flow conditions without considering flow oscillation. Therefore to improve the understanding on flow oscillation CHF, in this paper a new CHF correction factor to predict the CHF values under flow oscillation conditions has been developed from 126 experimental data. Also to investigate the dominant factor on flow oscillation CHF parametric trends are analyzed by using the developed correction factor. The overall mean accuracy ratio of the developed correction factor is 1.033 with a standard deviation of 0.195. The RMS errors 0.198. Its assessment shows that the predictions agree well with the experimental data within 25% error bounds.

  • PDF

Enhanced Variable On-time Control of Critical Conduction Mode Boost Power Factor Correction Converters

  • Kim, Jung-Won;Yi, Je-Hyun;Cho, Bo-Hyung
    • Journal of Power Electronics
    • /
    • 제14권5호
    • /
    • pp.890-898
    • /
    • 2014
  • Critical conduction mode boost power factor correction converters operating at the boundary of continuous conduction mode and discontinuous conduction mode have been widely used for power applications lower than 300W. This paper proposes an enhanced variable on-time control method for the critical conduction mode boost PFC converter to improve the total harmonic distortion characteristic. The inductor current, which varies according to the input voltage, is analyzed in detail and the optimal on-time is obtained to minimize the total harmonic distortion with a digital controller using a TMS320F28335. The switch on-time varies according to the input voltage based on the computed optimal on-time. The performance of the proposed control method is verified by a 100W PFC converter. It is shown that the optimized on-time reduces the total harmonic distortion about 52% (from 10.48% to 5.5%) at 220V when compared to the variable on-time control method.

한국형 중환자실 간호근무환경 측정도구 개발 및 평가 (Development and Validation of a Korean Nursing Work Environment Scale for Critical Care Nurses)

  • 이효진;문지현;김세라;심미영;김정연;이미애
    • 임상간호연구
    • /
    • 제27권3호
    • /
    • pp.279-293
    • /
    • 2021
  • Purpose: The purpose of this study was to develop a Korean nursing work environment scale for critical care nurses (KNWES-CCN) and verify its validity and reliability. Methods: A total of 46 preliminary items were selected using content validity analysis of experts on 64 candidate items derived through literature reviews and in-depth interviews with critical care nurses. 535 critical care nurses from 21 hospitals responded to the preliminary questionnaire from February to March 2021. The collected data were analysed using construct, convergent and discriminant validities, and internal consistency and test-retest reliability. Results: The 23 items in 4 factors accounted for 55.6% of the total variance were identified through item analysis and exploratory factor analysis (EFA). EFA was performed with maximum likelihood method including direct oblimin method. In the confirmatory factor analysis, KNWES-CCN consisted of 21 items in 4 factors by deleting the items that were not meet the condition that the factor loading over .50 or the squared multiple correlation over .30. This model was considered to be suitable because it satisfied the fit index and acceptable criteria of the model [𝒳2=440.47 (p<.001), CMIN/DF=2.41, GFI=.86, SRMR=.06, RMSEA=.07, TLI=.90, CFI=.91]. The item total correlation values ranged form .32 to .73 and its internal consistency was Cronbach's α=.92. The reliability of the test-retest correlation coefficient was .72 and the intra-class correlation coefficient was .83. Conclusion: The KNWES-CCN showed good validity and reliability. Therefore, it is expected that the use of this scale would measure and improve nursing work environment for critical care nurses in Korea.

실험계획법을 이용한 주축 형상 설계에 관한 연구 (A Study on Spindle Shape Design using Design of Experiments)

  • 선재호;이춘만
    • 한국정밀공학회지
    • /
    • 제26권4호
    • /
    • pp.120-127
    • /
    • 2009
  • Spindle units of machine tool are very important part in the manufacturing area. Recently high speed machining has become the main issue of metal cutting. To develop high speed machine tools, a lot of studies have been carried out for high speed spindle. Due to increase of the rotational speed of the spindle, there has been renewal of interest in vibration of spindle. This paper concerns the improvement of spindle design using design of experiments. To improve the design of critical speed and weight of spindle, the experiments using central composite method have been carried out. The targets are critical speed and weight of spindle. For optimization of critical speed and weight and optimization of only critical speed by operation of all area search through response optimizer, the result of analysis has improved design of each factor. Finite element analyses are performed by using the commercial codes ARMD, CATIA V5 and ANSYS workbench. From the results, it has been shown that the proposed method is effective for modification of spindle design to improve critical speed and weight.

구형 간극에서의 임계출력에 관한 상관식 검증 및 보완 (Correlation Verification and Revision of Critical Power in a Hemispherical Narrow Gap)

  • 하광순;박래준;김상백;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.411-414
    • /
    • 2002
  • The CHFG(Critical Heat Flux in Cap) test results have been evaluated to quantify the critical powers in hemispherical narrow gaps and Park's correlation has been verified. For verification of the Park's correlation, the critical powers in hemispherical narrow gaps have been measured using water at a pressure of 0.1-0.3 WPa for the hemispherical gap thickness of 1.0mm, and the heated top diameter of 238mm The measured critical powers were compared with Park's and Monde's correlation. As a results, the Park's correlation was most accurate of other correlations, however, estimated the critical powers somewhat larger than measured ones. So, it was suggested that the diameter factor in Park's correlation should be revised.

  • PDF

주요성과요인분석과 그 활용방안에 관한 연구 :한국 철강산업에의 적용사례 (A Study on Critical Success Factor Analysis and its Usage : An Aplication Study to the Steel Industry in Korea)

  • 문태수;신영종
    • 경영과학
    • /
    • 제8권1호
    • /
    • pp.13-25
    • /
    • 1991
  • Over the past few years, there has been a growing interest in using information technology for competitive advantage. A sustainable advantage is the key to the survival and growth of a firm. The successful implementation of information technology is dependent on efficient information systems planning. But the correct and complete information, requirements for effective information systems planning are frequently very difficult to obtain. In this paper the Critical Success Factors(CSF) method was employed as a means of managerial information requirements analysis for information systems planning in Korea's steel industry. CSFs are one of the few areas of activity that must go well to ensure the success of an organization. This paper addresses the concept and hierarchy of CSF analysis as a methodology in identifying corporate information needs and concludes with the use and benefit of results of CSF analysis.

  • PDF

소닉노즐을 이용한 천연가스 유량측정에서 임계유동인자 계산 및 국제비교 결과 (Evaluation of Critical Flow Factor in Natural Gas Flow Measurement Using Sonic Nozzle and International Comparison Results)

  • 하영철;허재영
    • 대한기계학회논문집B
    • /
    • 제23권7호
    • /
    • pp.911-917
    • /
    • 1999
  • The sonic nozzle is widely used as reference device for calibrating flowmeters In gas flow measurement and its use requires the Critical Flow Factor(CFF) based on the thermodynamic properties of the gas at the nozzle throat. ISO-9300 provides the calculating method of the factor. But since the CFF from this method show an error over ${\pm}0.5%$ In specific conditions and of ${\pm}0.1{\sim}{\pm}0.2%$ in common Natural Gas(NG) custody transfer condition. this method cannot be applied for gas flow measurement with sonic nozzle. Each research bodies or organizations of the world have joined in order to calculate the CFF more accurately. They have performed these works using their own method and compared the results with each other under the management of ISO. KOGAS have joined those works, because the high-pressure natural gas flow calibration facility of KOGAS will be constructed in late 1999, and then had necessities to calculate a CFF accurately. The calculation method of KOGAS was using the equation of state from AGA-8('94), high accuracy model of ideal gas properties and the solutions of thermodynamic equations. The evaluation results have had a very good consistency within ${\pm}0.05%$ in most NO custody transfer conditions compared to the speed of sound for methane and also shown that the CFF was within ${\pm}0.1%$ compared to the results of other works of the world.

샤피충격시험기를 이용한 고무보강 폴리머재료의 파괴인자 결정에 관한연구 (A study on the Determination of Fractuye Parameters for Rubber Toughened Polymeric Materials Using Instrumented Charpy Impact Test)

  • 최영식;박명균;박세만
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.389-394
    • /
    • 2001
  • The notched Charpy and Izod impact tests arc the most prevalent techniques used to characterize the effects of high impulse loads on ploymeric materials. An analysis method for rubber toughened PVC is suggested to evaluate critical strain energy release rates(Gc) from the Charpy impact energy measurements. An Instrumented Charpy impact tester was used to extract ancillary information concerning fracture properties in addition to total fracture properties and maximum critical loads. The stress intensity factor Kd was computed for varying amounts of rubber contents from the obtained maximum critical loads and also toughening effects were investigated as well.

  • PDF

고로슬래그 미분말을 사용한 고유동콘크리트의 내동해성에 관한 실험적 연구 (An Experimental Study on the Frost Resistance of High-Flowing Concrete Using Granulated Blast-Furnace Slag)

  • 김무한;권영진;강석표
    • 콘크리트학회논문집
    • /
    • 제12권2호
    • /
    • pp.43-51
    • /
    • 2000
  • This study is to investigate for the frost resistance of high-flowing concrete using finely ground granulated blast-furnace slag with experimental parameters, such as type of binder, type of superplasticizer and method of curing. The resistance to freezing and thawing of high-flowing concrete by type of binder and superplasticizer is presented differently. Though the frost resistance of high-flowing concrete is satisfactory under standard condition, it is required that high-flowing concrete has entrained air like plain concrete. Because the critical spacing factor, being capacity of frost resistance, of high-flowing concrete is longer that of plain concrete, the frost resistance of high-flowing concrete, using finely ground granulated furnace blast slag, is superior to that of plain concrete.

변형 모드를 이용한 모니터용 회로 기판의 파손 저감 설계에 관한 연구 (Failure-Proof Design of the PCB of a Monitor Using Deformed Mode Shape)

  • 박상후;이부윤
    • 한국정밀공학회지
    • /
    • 제18권1호
    • /
    • pp.111-116
    • /
    • 2001
  • A practical scheme to reduce failure of the PCB(Printed Circuit Board) of a monitor is introduced using deformed mode shape under mechanical shock. When the monitor is given critical shock loads, cracks are commonly initiated at the tip of a hole on the PCB. Accordingly, a deformed mode shape of the PCB is obtained using a FEM code to define a weak point on the PCB under mechanical shock, and then the position and direction of the hole is determined to prevent the failure at the critical mode shape. Also, the stress intensity factor around the weak point on the PCB is calculated to check the possibility of fracture by normal tensile stress. In conclusion, present research is useful to assist the practical design of components-layout on the PCB.

  • PDF