DOI QR코드

DOI QR Code

소닉노즐을 이용한 천연가스 유량측정에서 임계유동인자 계산 및 국제비교 결과

Evaluation of Critical Flow Factor in Natural Gas Flow Measurement Using Sonic Nozzle and International Comparison Results

  • 하영철 (한국가스공사 연구개발원 공급연구실) ;
  • 허재영 (한국가스공사 연구개발원 공급연구실)
  • 투고 : 1999.02.01
  • 발행 : 1999.07.01

초록

The sonic nozzle is widely used as reference device for calibrating flowmeters In gas flow measurement and its use requires the Critical Flow Factor(CFF) based on the thermodynamic properties of the gas at the nozzle throat. ISO-9300 provides the calculating method of the factor. But since the CFF from this method show an error over ${\pm}0.5%$ In specific conditions and of ${\pm}0.1{\sim}{\pm}0.2%$ in common Natural Gas(NG) custody transfer condition. this method cannot be applied for gas flow measurement with sonic nozzle. Each research bodies or organizations of the world have joined in order to calculate the CFF more accurately. They have performed these works using their own method and compared the results with each other under the management of ISO. KOGAS have joined those works, because the high-pressure natural gas flow calibration facility of KOGAS will be constructed in late 1999, and then had necessities to calculate a CFF accurately. The calculation method of KOGAS was using the equation of state from AGA-8('94), high accuracy model of ideal gas properties and the solutions of thermodynamic equations. The evaluation results have had a very good consistency within ${\pm}0.05%$ in most NO custody transfer conditions compared to the speed of sound for methane and also shown that the CFF was within ${\pm}0.1%$ compared to the results of other works of the world.

키워드